Displaying publications 21 - 27 of 27 in total

Abstract:
Sort:
  1. Tan NH, Ponnudurai G
    Comp. Biochem. Physiol., B, 1990;95(3):577-82.
    PMID: 2158874
    1. The hemorrhagic, procoagulant, anticoagulant, phosphodiesterase, alkaline phosphomonoesterase, 5'-nucleotidase, hyaluronidase, arginine ester hydrolase, phospholipase A, L-amino acid oxidase and protease activities of 31 samples of venom from three species of Agkistrodon (A. bilineatus, A. contortrix and A. piscivorus) and 10 venom samples from five other related species belonging to the same tribe of Agkistrodontini were examined. 2. The results indicate that interspecific differences in certain biological activities of the Agkistrodon venoms are more marked than individual variations of the activities, and that these differences can be used for differentiation of the species. Particularly useful for this purpose are the phosphodiesterase, arginine ester hydrolase and anticoagulant activities of the venoms. 3. Venoms of the subspecies of A. contortrix and A. piscivorus do not differ significantly in their biological activities.
    Matched MeSH terms: Blood Coagulation/drug effects
  2. Tan NH, Ponnudurai G
    Comp. Biochem. Physiol., B, 1990;96(4):683-8.
    PMID: 2171867
    1. The hemorrhagic, procoagulant, anticoagulant, phosphodiesterase, hyaluronidase, alkaline phosphomonoesterase, 5'-nucleotidase, arginine ester hydrolase, phospholipase A, L-amino acid oxidase and protease activities of 26 samples of venoms of 13 taxa of Vipera were determined and the Sephadex G-75 gel filtration patterns for some of the venoms were also examined. 2. The results indicate the presence of certain common characteristics among the venoms, particularly if V. russelli is excluded from the comparison. The results also support the recently proposed reassignment of V. russelli to a separate genus. 3. The data show that information on venom biological properties can be used for differentiation of venoms of many species of Vipera. Particularly useful for this purpose are the protease, phosphodiesterase, phospholipase A and the procoagulant activities and the Sephadex G-75 gel filtration patterns of the venoms.
    Matched MeSH terms: Blood Coagulation/drug effects
  3. Reid HA
    Clin. Toxicol., 1970 Sep;3(3):473-82.
    PMID: 5520050
    Matched MeSH terms: Blood Coagulation/drug effects
  4. Fong AYY, Tiong LL, Tan SSN, Geruka D, Apil GG, Choo CW, et al.
    Clin Appl Thromb Hemost, 2020 12 8;26:1076029620972473.
    PMID: 33284050 DOI: 10.1177/1076029620972473
    Routine coagulation tests do not enable rapid, accurate determination of direct oral anticoagulant (DOAC) therapy. The ecarin clotting assay (ECA), performed on the ClotPro viscoelastic testing device, may enable sensitive and specific detection of dabigatran. We assessed the association between trough plasma dabigatran concentration and clotting time (CT) in the ClotPro ECA, in patients with non-valvular atrial fibrillation (NVAF). Each patient provided a single venous blood sample, ∼1 hour before dabigatran dosing. The study included 118 patients, of whom 64 were receiving dabigatran 110 mg twice daily and 54 were receiving 150 mg twice daily. ECA CT was moderately correlated with trough plasma dabigatran concentration (r = 0.80, p < 0.001). Slight trends toward increased plasma dabigatran concentration and prolonged ECA CT were apparent with 150 mg versus the 110 mg dose (differences not statistically significant). Individuals with creatinine clearance below 50 mL/minute had significantly higher plasma dabigatran concentrations and significantly prolonged ECA CT versus those with creatinine clearance ≥50 mL/minute. In conclusion, this preliminary study has demonstrated that CT in the ClotPro ECA reflects the plasma concentration of dabigatran in patients with NVAF. The ECA could potentially be used to assess the impact of dabigatran on a patient's coagulation status.
    Matched MeSH terms: Blood Coagulation/drug effects*
  5. Ng DPJ, Duffull SB, Faed JM, Isbister GK, Gulati A
    Clin Appl Thromb Hemost, 2018 May;24(4):669-676.
    PMID: 28731370 DOI: 10.1177/1076029617711802
    A well-accepted test for monitoring anticoagulation by enoxaparin is not currently available. As inadequate dosing may result in thrombosis or bleeding, a clinical need exists for a suitable test. Previous in silico and in vitro studies have identified factor Xa as an appropriate activating agent, and the phospholipid Actin FS as a cofactor for a Xa clotting time (TenaCT) test. A proof-of-concept study was designed to (1) explore the reproducibility of the TenaCT test and (2) explore factors that could affect the performance of the test. In vitro clotting time tests were carried out using plasma from 20 healthy volunteers. The effect of enoxaparin was determined at concentrations of 0.25, 0.50, and 1.0 IU/mL. Clotting times for the volunteers were significantly prolonged with increasing enoxaparin concentrations. Clotting times were significantly shortened for frozen plasma samples. No significant differences in prolongation of clotting times were observed between male and female volunteers or between the 2 evaluated age groups. The clotting times were consistent between 2 separate occasions. The TenaCT test was able to distinguish between the subtherapeutic and therapeutic concentrations of enoxaparin. Plasma should not be frozen prior to performing the test, without defining a frozen plasma reference range. This study provided proof-of-concept for a Xa-based test that can detect enoxaparin dose effects, but additional studies are needed to further develop the test.
    Matched MeSH terms: Blood Coagulation/drug effects*
  6. Jaganathan SK, Mohandas H, Sivakumar G, Kasi P, Sudheer T, Avineri Veetil S, et al.
    Biomed Res Int, 2014;2014:963149.
    PMID: 24955370 DOI: 10.1155/2014/963149
    Blood compatibility of metallocene polyethylene (mPE) was investigated after modifying the surface using hydrochloric acid. Contact angle of the mPE exposed to HCl poses a decrease in its value which indicates increasing wettability and better blood compatibility. Surface of mPE analyzed by using FTIR revealed no significant changes in its functional groups after treatment. Furthermore, scanning electron microscope images supported the increasing wettability through the modifications like pit formations and etching on the acid rendered surface. To evaluate the effect of acid treatment on the coagulation cascade, prothrombin time (PT) and activated partial thromboplastin time (APTT) were measured. Both PT and APTT were delayed significantly (P < 0.05) after 60 min exposure implying improved blood compatibility of the surfaces. Hemolysis assay of the treated surface showed a remarkable decrease in the percentage of lysis of red blood cells when compared with untreated surface. Moreover, platelet adhesion assay demonstrated that HCl exposed surfaces deter the attachment of platelets and thereby reduce the chances of activation of blood coagulation cascade. These results confirmed the enhanced blood compatibility of mPE after HCl exposure which can be utilized for cardiovascular implants like artificial vascular prostheses, implants, and various blood contacting devices.
    Matched MeSH terms: Blood Coagulation/drug effects