Displaying publications 41 - 60 of 61 in total

Abstract:
Sort:
  1. Patil PG, Lim HF
    J Prosthet Dent, 2023 Jul;130(1):14-18.
    PMID: 34774303 DOI: 10.1016/j.prosdent.2021.08.005
    Fabricating a new crown to retrofit with an existing removable partial denture (RPD) is a complex procedure for both clinician and dental laboratory technician. The presented technique facilitates the fabrication and retrofitting of a metal-ceramic crown onto the principal abutment of the existing RPD by using 2-step intraoral scanning (with and without the RPD in place) and 2 different 3-dimensionally printed casts. The technique enables the dental laboratory technician to precisely reproduce the retentive areas, guiding planes, and rest seats on the retrofitted crown.
  2. Patil PG, Seow LL, Uddanwadikar R, Pau A, Ukey PD
    J Prosthet Dent, 2024 Feb;131(2):281.e1-281.e9.
    PMID: 37985307 DOI: 10.1016/j.prosdent.2023.10.023
    STATEMENT OF PROBLEM: The 2-implant mandibular overdenture (2IMO) is a popular treatment for patients with mandibular edentulism. However, information on the influence of implant positions on crestal strain is lacking.

    PURPOSE: The purpose of this in vitro study was to evaluate the crestal strain around 2 implants to support mandibular overdentures when placed at different positions.

    MATERIAL AND METHODS: Edentulous mandibles were 3-dimensionally (3D) designed separately with 2 holes for implant placement at similar distances of 5, 10, 15, and 20 mm from the midline, resulting in 4 study conditions. The complete denture models were 3D designed and printed from digital imaging and communications in medicine (DICOM) images after scanning the patient's denture. Two 4.3×12-mm dummy implants were placed in the preplanned holes. Two linear strain gauges were attached on the crest of the mesial and distal side of each implant (CH1, CH2, CH3, and CH4) and connected to a computer to record the electrical signals. Male LOCATOR attachments were attached, the mucosal layer simulated, and the denture picked up with pink female nylon caps. A unilateral and bilateral force of 100 N was maintained for 10 seconds for each model in a universal testing machine while recording the maximum strains in the DCS-100A KYOWA computer software program. Data were analyzed by using 1-way analysis of variance, the Tukey post hoc test, and the paired t test (α=.05).

    RESULTS: Under bilateral loading, the strain values indicated a trend with increasing distance between the implants with both right and left distal strain gauges (CH4 and CH1). The negative (-ve) values indicated the compressive force, and the positive (+ve) values indicated the tensile force being applied on the strain gauges. The strain values for CH4 ranged between -166.08 for the 5-mm and -251.58 for the 20-mm position; and for CH1 between -168.08 for the 5-mm and -297.83 for the 20-mm position. The remaining 2 mesial strain gauges for all 4 implant positions remained lower than for CH4 and CH1. Under unilateral-right loading, only the right-side distal strain gauge CH4 indicated the increasing trend in the strain values with -147.5 for the 5-mm, -157.17 for the 10-mm, -209.33 for the 15-mm, and -234.75 for the 20 mm position. The remaining 3 strain gauges CH3, CH2, and CH1 ranged between -28.33 and -107.17. For each position for both implants, significantly higher (P

  3. Patil PG, Seow LL
    J Prosthet Dent, 2022 Nov 18.
    PMID: 36411113 DOI: 10.1016/j.prosdent.2022.09.007
    STATEMENT OF PROBLEM: The 2-implant mandibular overdenture (2IMO) is a popular treatment for patients with an edentulous mandible, but information on the effect of the optimum implant position on the peri-implant crestal bone level with immediate loading protocols is lacking.

    PURPOSE: The purpose of this prospective clinical study was to evaluate correlations between different implant positions and crestal bone loss and between interimplant distance and the crestal bone loss in patients with 2IMOs with immediate loading protocols at 1-year follow-up.

    MATERIAL AND METHODS: A total of 24 participants (13 men, 11 women, mean ±standard deviation age 63.25 ±10.76 years) were treated with 2IMOs (48 Ti-Zr implants) by a single operator between August 2015 and October 2020. The implant diameters (3.3 mm or 4.1 mm) and lengths (10 mm or 12 mm) were selected based on the crestal bone width, and the implants were placed, if possible, in the canine regions. Implant positions and interimplant distance (mm) were measured intraorally with dividers. Prefabricated mandibular dentures were immediately loaded with the LOCATOR-attachments by using a direct intraoral pickup procedure. Crestal bone-level changes were measured with a software program on the mesial and distal sides of each implant from periapical radiographs made with a paralleling technique (at baseline and 1-year follow-up). The measurement values were normalized. The Spearman rho correlation test and paired samples t tests were used for data analysis (α=.05).

    RESULTS: The mean ±standard deviation position of the implants from the midline was 8.78 ±2.25 mm (9.00 ±2.22 mm right side, 8.56 ±2.31 mm left side), and the mean interimplant distance was 16.94 ±4.03 mm. At 1-year follow-up, the mean ±standard deviation crestal bone loss was 0.50 ±0.47 mm (n=48) (0.57 ±0.65 mm mesial, 0.43 ±0.53 mm distal). The mean ±standard deviation crestal bone loss was 0.46 ±0.4 mm with Ø3.3-mm implants (n=42) and 0.9 ±0.8 mm with Ø4.1-mm implants (n=6) (P=.005). Implant positions were negatively correlated (rs=-0.37) with the crestal bone loss, and the correlation was significant (P=.009). Interimplant distances were also negatively correlated with crestal bone loss (rs=-0.60; P=.002). Bone loss on the mesial side was positively correlated with that on the distal side rs=0.20; however, the correlation was not significant (P=.16).

    CONCLUSIONS: A weak and negative correlation was found between the implant position from the midline and the crestal bone loss and also between the interimplant distance and crestal bone loss in patients provided with 2IMOs with immediate loading protocols.

  4. Patil PG, Seow LL, Uddanwadikar R, Pau A, Ukey PD
    J Prosthet Dent, 2024 Apr;131(4):675-682.
    PMID: 35667890 DOI: 10.1016/j.prosdent.2022.04.018
    STATEMENT OF PROBLEM: The edentulous mandible is commonly treated with a 2-implant overdenture. A change in diameter of the implants may affect the biomechanical behavior of the overdenture, but information on these effects is lacking.

    PURPOSE: The purpose of this 3D finite element analysis study was to evaluate the biomechanical behavior of 2-implant mandibular overdentures (2IMO) and their individual components by using implants of different diameters.

    MATERIAL AND METHODS: A 3D mandibular model was obtained from the cone beam computed tomography (CBCT) images of a 59-year-old edentulous man, and a 3D denture model was developed from intraoral scanning files in the Mimics software program. A 3D model of different diameters of implants (2.5 mm, 3.0 mm, 3.5 mm, and 4.0 mm) with a LOCATOR attachment was developed in the Solidworks software program. Two same-sized implants were inserted in the mandibular model at 10 mm from the midline in the 3Matics software program. A vertical load of 100 N was applied on the first molar region on the right side or both sides in the ANSYS software program. The maximum von Mises stresses and strains were recorded and analyzed.

    RESULTS: Stresses within the implants decreased with an increase in diameter (from 2.5 mm to 3 mm, 3.5 mm, and 4.0 mm) of the implants. The highest stresses were observed with 2.5-mm-diameter implants (0.949 MPa under unilateral and 0.915 MPa under bilateral loading) and the lowest with Ø4-mm implants (0.710 MPa under unilateral and 0.703 MPa under bilateral loading). The strains on the implants ranged between 0.0000056 and 0.0000097, and those on the mandible ranged between 0.0000513 and 0.0000566 across all diameters of the implants without following a specific trend.

    CONCLUSIONS: In 2IMO, the stresses in the implants and mandible decreased with an increase in the diameter of the implants. The implants of lesser diameter (2.5 mm) exhibited the highest stresses and strains, and the implants of the largest diameter (4 mm) exhibited the lowest stresses and strains under unilateral and bilateral loading conditions.

  5. Rahman AM, Jamayet NB, Nizami MMUI, Johari Y, Husein A, Alam MK
    J Prosthet Dent, 2021 Jan 17.
    PMID: 33472753 DOI: 10.1016/j.prosdent.2020.07.026
    STATEMENT OF PROBLEM: The climate of tropical Southeast Asia includes high humidity and ultraviolet radiation that reduce the lifespan of silicone prostheses by inducing changes in their mechanical properties and color stability. Studies on the surface roughness (SR) and mechanical properties of different silicone elastomers (SEs) subjected to the natural tropical weather of Southeast Asia are lacking.

    PURPOSE: The purpose of this in vitro study was to evaluate the SR, tensile strength (TS), and percentage elongation (% E) of different SEs subjected to outdoor weathering in the Malaysian climate.

    MATERIAL AND METHODS: Type-II dumbbell-shaped specimens (N-120) (nonweathered=15, weathered=15) were made from 3 room-temperature vulcanized (A-2000, A-2006, and A-103) and 1 heat-temperature vulcanized (M-511) silicone (Factor II). For 6 months, weathered specimens were subjected to outdoor weathering inside a custom exposure rack. Simultaneously, the nonweathered specimens were kept in a dehumidifier. Subsequently, the SR was measured with a profilometer; TS and % E were measured by using a universal testing machine. Two-way ANOVA was used to compare the means of the tested properties of the nonweathered and weathered specimens, and pairwise comparison was carried out between the silicones (α=.05).

    RESULTS: After outdoor weathering, the SR, TS, and % E were adversely affected by weathering in the Malaysian environment. Among the silicone materials, A-2000 showed the least TS changes (2.51 MPa), while A-2006 demonstrated significant changes in percentage elongation after outdoor weathering (266.5%). M-511 exhibited the highest mean value (2.50 μm) for SR changes. In addition, A-103 SE showed statistically significant differences in most pairwise comparisons for all 3 dependent variables.

    CONCLUSIONS: Based on the evaluation of mechanical properties, A-103 can be suggested as a suitable silicone for maxillofacial prostheses fabricated for tropical climates. However, A-2000 can be a suitable alternative, although significant changes to surface roughness were detected after outdoor weathering.

  6. Razak AA, Harrison A
    J Prosthet Dent, 1997 Apr;77(4):353-8.
    PMID: 9104710
    Dimensional accuracy of a composite inlay restoration is important to ensure an accurate fit and to minimize cementation stresses.
  7. Saker S, El-Kholany N, El-Gendy A, Fadhil ON, Maria OM
    J Prosthet Dent, 2014 Apr 22.
    PMID: 24767901 DOI: 10.1016/j.prosdent.2013.07.030
    This article has been withdrawn at the request of the author(s) and/or editor. The Publisher apologizes for any inconvenience this may cause. The full Elsevier Policy on Article Withdrawal can be found at http://www.elsevier.com/locate/withdrawalpolicy.
  8. See WL, Khoo TL, Mohan M, Nimbalkar S, Patil PG
    J Prosthet Dent, 2024 Apr 22.
    PMID: 38653688 DOI: 10.1016/j.prosdent.2024.03.021
    STATEMENT OF PROBLEM: Standard surgical and prosthodontic protocols for managing partially dentate patients with implant-supported removable partial dentures (ISRPDs) are lacking.

    PURPOSE: The purpose of this systematic review was to determine clinical and patient-reported outcome measures (PROMs) in patients provided with ISRPDs in distal edentulous arches based on different surgical and prosthodontic protocols.

    MATERIAL AND METHODS: An electronic and manual literature search was conducted in 3 databases, PubMed/MEDLINE, SCOPUS, and Cochrane Library, for clinical studies on distal extension ISRPDs related to clinical and patient-reported outcomes. Kennedy Class I and II arches described in articles published from January 2000 to December 2023 were included. Clinical parameters regarding implant type, location, loading protocols, and implant survival rate and PROMs including masticatory performance, esthetics, and overall satisfaction were compared. The risk of bias was determined by using the Cochrane Risk of Bias Tool 2.0 (RoB 2.0).

    RESULTS: An initial total of 103 studies were identified, but only 11 articles were selected after implementing the inclusion and exclusion criteria. Ten studies evaluated PROMs, and 6 studies evaluated clinical outcomes (5 studies evaluated both). The implant survival rate ranged from 91.7% to 100%, with no clear differentiation among the studies with immediate or delayed loading protocols. Most studies described implants positioned in the molar region. In general, patient satisfaction and oral health-related quality of life (OHRQoL) improved significantly with ISRPDs compared with conventional removable partial dentures (RPDs) or RPDs with healing abutments. Posttreatment clinical outcomes revealed stable peri-implant health with no significant bone loss or prosthetic complications. No specific implant configuration, including implant type and location or attachment system, appeared to be better than another. Ball attachments were the commonly used attachments. Two studies were of high risk and 3 studies of low risk. The remaining 6 studies were judged to have some concerns based on the RoB 2.0 analysis.

    CONCLUSIONS: Providing an ISRPD improved patient satisfaction, OHRQoL, and the clinical outcomes in distal extension situations, with most studies positioning the implants in the molar region. The type of attachment did not significantly affect the outcomes, although ball attachments were the most used attachment in ISRPDs.

  9. Sivakumar I, Arunachalam S, Choudhary S, Buzayan MM
    J Prosthet Dent, 2021 Jun;125(6):862-869.
    PMID: 32694022 DOI: 10.1016/j.prosdent.2020.04.001
    STATEMENT OF PROBLEM: Immunosuppression and coinfections associated with human immunodeficiency virus (HIV) infection pose a relative contraindication for dental implant therapy. However, although implants have been placed in patients with HIV with reasonable success, how HIV infection affects their survival is unclear.

    PURPOSE: The purpose of this systematic review of the literature and meta-analysis was to analyze the data on the survival of dental implants in patients with HIV.

    MATERIAL AND METHODS: A search for relevant articles published up to November 2019 was performed in PubMed/Medline and Cochrane databases, Clinicaltrials.gov, and Google Scholar. Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines were adopted for the conduct of the systematic review. The most pertinent data were extracted and pooled for qualitative and quantitative analyses with 95% confidence intervals. Heterogeneity was analyzed by using I-squared statistics.

    RESULTS: A total of 8 studies involving 411 individuals with HIV and 1109 implants were included in the meta-analysis. The mean follow-up period was 2.8 years. A pooled estimate of 95% of implant survival rate with 95% confidence interval(92% to 96%) was noted. Heterogeneity across the 8 studies was found to be 41% with moderate true variability.

    CONCLUSIONS: This systematic review demonstrated that HIV infection does not pose a serious threat to implant survival on short-term evaluation, but the evidence is of low quality.

  10. Soo SY, Lee SM, Tew IM, Mohd Dom TN, Yahya NA
    J Prosthet Dent, 2023 Jul 17.
    PMID: 37468369 DOI: 10.1016/j.prosdent.2023.06.003
    STATEMENT OF PROBLEM: A discrepancy between dentists' assessments and patients' expectations during prosthodontic treatment is inevitable. Incorporating dental patients' concerns about their prosthodontic treatment needs is essential during treatment planning, yet studies assessing these needs in adult dental patients are lacking.

    PURPOSE: The purpose of this study was to develop and validate a novel instrument, termed the questionnaire on perceived prosthodontic treatment needs (PPTN), that assesses perceived prosthodontic treatment needs in adults.

    MATERIAL AND METHODS: The PPTN was developed following a literature review, consultation with healthcare workers, and patient interviews. It included 15 questions and a self-rated need for prosthodontic treatment, categorized on a Likert scale. A cross-sectional descriptive study was completed on 193 dental patients seeking or receiving prosthodontic treatment.

    RESULTS: Three perceived prosthodontic treatment need factors were identified (psychosocial impact, esthetic concern, and function) by using exploratory factor analysis. A higher PPTN score indicated greater perceived prosthodontic treatment needs. The identified factors represent 67.8% of the variance with eigenvalues of >1. The PPTN had a high degree of internal consistency and reliability, as the final questionnaire received a Cronbach alpha of 0.75 and an intraclass coefficient of 0.75 with a 95% confidence interval of 0.68 to 0.80 (F(192, 576)=3.94, P

  11. Sulong MZ, Aziz RA
    J Prosthet Dent, 1990 Mar;63(3):342-9.
    PMID: 2407832
    This is a review of the literature concerning wear related to the following materials used in dentistry: dental amalgam, composite resins, and glass-ionomer cements, as well as natural tooth substance. Discussions are included on both in vivo and in vitro studies in which various methods were used to help determine wear resistance.
  12. Sulong MZ, Setchell DJ
    J Prosthet Dent, 1991 Dec;66(6):743-7.
    PMID: 1805022
    Adhesive bond strength studies for the tray adhesive of an addition vinyl polysiloxane (President) impression material were conducted with an acrylic resin, chromium-plated brass, and plastic trays. Tensile and shear stress studies were performed on the Instron Universal testing machine. Acrylic resin specimens roughened with 80-grit silicon carbide paper exhibited appreciably higher bond strengths compared with different types of tray material and methods of surface preparation.
  13. Tan WY, Ng JZL, Ajit Bapat R, Vijaykumar Chaubal T, Kishor Kanneppedy S
    J Prosthet Dent, 2021 May;125(5):766.e1-766.e8.
    PMID: 33752904 DOI: 10.1016/j.prosdent.2021.02.018
    STATEMENT OF PROBLEM: Lingual plate perforation can be life-threatening when vital structures are damaged during implant placement. Knowledge of the anatomy of lingual concavities is imperative for safe implant surgery.

    PURPOSE: The purpose of this clinical study was to determine the prevalence of type of posterior mandibular ridge morphology in a Malaysian population and to evaluate the buccolingual width of the alveolar ridge (Wb and Wc); alveolar ridge height (Vcb); and concavity angle, length, and depth for both left and right first and second molars in different age groups and sexes by using cone beam computed tomography (CBCT).

    MATERIAL AND METHODS: Bilateral posterior mandibular lingual concavities at the first and second molars were retrospectively studied in cross-sectional views of 150 CBCT scans (n=600 sites evaluated). The sample size was calculated at a power of 80%, confidence interval of 95%, and margin of error of .05. The buccolingual width from the base and crest of the ridge and the ridge height were measured to determine the type of ridge. For the U-shaped ridge, the concavity angle, length, and depth were assessed. The independent t test was used to compare mean values of CBCT measurements between sexes and tooth type, while the ANOVA and Pearson chi-squared test were used to determine the correlations with age groups and types of ridge morphology, respectively. To compare the left and right readings for first and second molars in the same patient, the paired t test was performed (α=.05 for all tests).

    RESULTS: The Pearson correlation showed a strong agreement between the 2 examiners with an interobserver reliability of 87.3%. Significant difference was noted in all dimensional measurements when comparing right and left first and second molars (P

  14. Tew IM, Soo SY, Pow EHN
    J Prosthet Dent, 2023 Nov 23.
    PMID: 38000966 DOI: 10.1016/j.prosdent.2023.10.028
    STATEMENT OF PROBLEM: Reports on digitally fabricated complete dentures are increasing. However, comprehensive evidence-based research on their cost-efficiency and patient-reported outcome measures (PROMs) is lacking.

    PURPOSE: The purpose of this systematic review was to compare the cost-effectiveness and PROMs between digitally and conventionally fabricated complete dentures.

    MATERIAL AND METHODS: An electronic search of publications from 2011 to mid-2023 was established using PubMed/Medline, EBSCOhost, and Google Scholar. Retrospective, prospective, randomized controlled, and randomized crossover clinical studies on at least 10 participants were included. A total of 540 articles were identified and assessed at the title, abstract, and full article level, resulting in the inclusion of 14 articles. Data on cost, number of visits, patient satisfaction, and oral health-related quality of life were examined and reported.

    RESULTS: The systematic review included 572 digitally fabricated complete dentures and 939 conventionally fabricated complete dentures inserted in 1300 patients. Digitally fabricated complete dentures require less clinical time with a lower total cost, despite higher material costs compared with the conventional fabrication technique. Digitally and conventionally fabricated complete dentures were found to have significant effects on mastication efficiency, comfort, retention, stability, ease of cleaning, phonetics, and overall patient satisfaction, as well as social disability, functional limitation, psychological discomfort, physical pain, and handicap.

    CONCLUSIONS: Digitally fabricated complete dentures are more cost-effective than conventionally fabricated dentures. There are various impacts of conventionally and digitally fabricated complete dentures on PROMs, and they are not better than one another.

  15. Vohra F, Al-Kheraif AA, Ab Ghani SM, Abu Hassan MI, Alnassar T, Javed F
    J Prosthet Dent, 2015 Sep;114(3):351-7.
    PMID: 26047803 DOI: 10.1016/j.prosdent.2015.03.016
    STATEMENT OF PROBLEM: Zirconia implants have been used for oral rehabilitation; however, evidence of their ability to maintain crestal bone and periimplant soft tissue health is not clear.

    PURPOSE: The purpose of this systematic review was to evaluate crestal bone loss (CBL) around zirconia dental implants and clinical periimplant inflammatory parameters.

    MATERIAL AND METHODS: The focus question addressed was, "Do zirconia implants maintain crestal bone levels and periimplant soft tissue health?" Databases were searched for articles from 1977 through September 2014 with different combinations of the following MeSH terms: "dental implants," "zirconium," "alveolar bone loss," "periodontal attachment loss," "periodontal pocket," "periodontal index." Letters to the editor, case reports, commentaries, review articles, and articles published in languages other than English were excluded.

    RESULTS: Thirteen clinical studies were included. In 8 of the studies, the CBL around zirconia implants was comparable between baseline and follow-up. In the other 5 studies, the CBL around zirconia implants was significantly higher at follow-up. Among the studies that used titanium implants as controls, 2 studies showed significantly higher CBL around zirconia implants, and in 1 study, the CBL around zirconia and titanium implants was comparable. The reported implant survival rates for zirconia implants ranged between 67.6% and 100%. Eleven studies selectively reported the periimplant inflammatory parameters.

    CONCLUSIONS: Because of the variations in study design and methodology, it was difficult to reach a consensus regarding the efficacy of zirconia implants in maintaining crestal bone levels and periimplant soft tissue health.

  16. Voon YS, Patil PG
    J Prosthet Dent, 2018 Apr;119(4):568-573.
    PMID: 28838820 DOI: 10.1016/j.prosdent.2017.05.011
    STATEMENT OF PROBLEM: The genial tubercle is a clinically palpable landmark in the mandible and can be identified in cone beam computed tomography (CBCT). Its location can be used to measure the safe zone in the interforaminal region of the mandible. These measurements may be helpful for implant treatment planning in patients with complete edentulism.

    PURPOSE: The purpose of this clinical study was to evaluate the safe distance in the interforaminal region of the mandible measured from the genial tubercle level for implant osteotomy in a Chinese-Malaysian population.

    MATERIAL AND METHODS: A total of 201 Digital Imaging and Communications in Medicine (DICOM) files were selected for the study from the CBCTs of dentate or edentulous Chinese-Malaysian adult patients with ongoing or completed treatments. Measurements were made with implant planning software. The anatomy of the whole mandible was assessed in the coronal cross-sectional, horizontal view and in panoramic view. Measurements were obtained in millimeters on one side by locating and marking a genial tubercle and then marking the mesial margin of the mental foramen and the anterior loop of the inferior alveolar nerve. The corresponding points of these landmarks were identified on the crest of the mandibular ridge to measure the linear distances. All the measurement steps were repeated on the other side. The linear distance of 2 mm was deducted from the total distance between the genial tubercle and the anterior loop separately for left and right side measurements to identify the safe zone. The mixed 2-way analysis of variance (ANOVA) test was used to analyze side and sex-related variations.

    RESULTS: The mean safe zone measured at the crestal level from the genial tubercle site on the left side of the mandible was 21.12 mm and 21.67 mm on the right side. A statistically significant (P

  17. Wong SK, Patil PG
    J Prosthet Dent, 2018 Aug;120(2):210-213.
    PMID: 29551376 DOI: 10.1016/j.prosdent.2017.10.019
    STATEMENT OF PROBLEM: The inferior alveolar nerve (IAN) frequently loops backward before exiting from the mental foramen and spreads several millimeters medially to the foramen. Implant placement in this area may damage the nerve if the anterior loop area is not carefully identified in a radiographic or computed tomography (CT) evaluation.

    PURPOSE: The purpose of this observational study was to measure the prevalence of the presence of the anterior loop and to estimate sex and ethnicity-related variations in anterior loop length in the Malaysian population.

    MATERIAL AND METHODS: A total of 100 cone beam computed tomography (CBCT) Digital Imaging and Communications in Medicine (DICOM) files were selected from a pool of 810 ongoing or completed patients in 3 different ethnic groups: Malay (33), Indian (33), and Chinese (34). The DICOM data were imported into commercial software. The IAN was traced with software along with the anterior loop and part of the incisive nerve. The vertical length of the nerve was estimated from the canal to the opening of the mental foramen from the cross-sectional view and translated to the panoramic view. Measurement was made from this point to the most anterior point of the anterior loop by following the trajectory of the nerve and was repeated on the opposite side. A 2-way mixed analysis of variance (ANOVA) test was carried out to evaluate the sex- and ethnicity-related variations (α=.05).

    RESULTS: The anterior loop was present in 94% of the 100 participants. Overall anterior loop length (AnLL) ranged between 0.73 and 7.99 mm with a mean length of 3.69 ±1.75 mm on the left side and 3.85 ±1.73 mm on the right side. Among all participants, no statistically significant differences were found between the left and right sides of the mandible (P=.379). Overall, no significant main effect of ethnicity (P=.869) or sex (P=.576) was found on AnLL measurements. Also, with multiple comparisons, no significant effect was found between each pair of ethnic groups. Men in all 3 ethnic groups had greater AnLL than women.

    CONCLUSIONS: The anterior loop was present in 94% of the 100 participants among the 3 major ethnic groups of Malaysia. Overall AnLL ranged between 0.73 and 7.99 mm and mean lengths of 3.69 ±1.75 mm on the left side and 3.85 ±1.73 mm on the right side, with no significant ethnicity- or sex-related variations.

  18. Xin YH, Ying TJ, Syeed MS, Veettil SK, Menon RK
    J Prosthet Dent, 2023 Feb 28.
    PMID: 36863936 DOI: 10.1016/j.prosdent.2023.01.007
    STATEMENT OF PROBLEM: Symptomatic denture stomatitis (DS) is a painful oral mucosal disorder that can impair quality of life in denture wearers. A complete cure of DS is difficult to achieve, and the most efficacious regimen to treat DS has not yet been conclusively established.

    PURPOSE: The purpose of this network meta-analysis was to assess the comparative efficacy of interventions used for the treatment of DS.

    MATERIAL AND METHODS: A search was conducted for trials published in Medline, Scopus, PubMed, and Cochrane Central Register of Controlled Trials from inception until February 2022 (PROSPERO Reg no: CRD42021271366). Network meta-analysis was performed on data from randomized controlled trials that assessed the comparative efficacy of any form of intervention for the treatment of DS in denture wearers. Agents were ranked according to their effectiveness in the treatment of DS based on outcomes using surface under the cumulative ranking (SUCRA).

    RESULTS: A total of 25 articles were included in the quantitative analysis. Topical antifungal agents (risk ratio [RR]=4.37[95% confidence interval [CI]: 2.15,8.90), topical antimicrobial agents used along with systemic antifungal agents (RR=4.25[95% CI: 1.79,10.33]), systemic antifungal agents (RR=4.25[95% CI: 1.79,10.10]), photodynamic therapy (RR=4.25[95% CI: 1.75,8.98]), and topical plant products (RR=3.40[95% CI: 1.59,7.26]) were found to effectively improve DS. Microwave disinfection concurrently administered with topical antifungal agents (RR=7.38(95% CI: 2.75,19.81), microwave disinfection 7.38[95% CI: 2.75,19.81]), topical antifungal agents (RR=4.88[95% CI: 1.92,12.42]), topical plant products (RR=4.49[95% CI: 1.70,11.82]), systemic antifungal agents together with topical antimicrobial agents (RR=3.85[95% CI: 1.33,11.10]), topical antimicrobial agents (RR=3.39[95% CI: 1.17,9.81]), systemic antifungal agents (RR=3.37[95% CI: 1.21,9.34]), and photodynamic therapy or photochemotherapy (PDT) (RR=2.93[95% CI: 1.01,8.47]) were found to effectively resolve mycological DS. Topical antifungals ranked highest in the SUCRA ranking for clinical improvement, whereas microwave disinfection concurrently administered with topical antifungal agents ranked highest for mycological resolution. None of the agents demonstrated significant side effects except for topical antimicrobial agents which demonstrated altered taste and staining of oral structures.

    CONCLUSIONS: Available evidence suggests that topical antifungals, microwave, and systemic antifungals are effective in the treatment of DS, but confidence in these findings is low because of the limited number of studies and a high risk of bias. Additional clinical trials are needed on photodynamic therapy, topical plant products, and topical antimicrobials.

  19. Yacob N, Ahmad NA, Safii SH, Yunus N, Abdul Razak F
    J Prosthet Dent, 2023 Jul;130(1):131.e1-131.e7.
    PMID: 37210224 DOI: 10.1016/j.prosdent.2023.04.017
    STATEMENT OF PROBLEM: How the build orientation of a 3-dimensionally (3D) printed denture affects microbial adhesion is unclear.

    PURPOSE: The purpose of this in vitro study was to compare the adherence of Streptococcus spp. and Candida spp. on 3D-printed denture bases prepared at different build orientations with conventional heat-polymerized resin.

    MATERIAL AND METHODS: Resin specimens (n=5) with standardized 28.3 mm2 surface area were 3D printed at 0 and 60 degrees, and heat-polymerized (3DP-0, 3DP-60, and HP, respectively). The specimens were placed in a Nordini artificial mouth (NAM) model and exposed to 2 mL of clarified whole saliva to create a pellicle-coated substratum. Suspensions of Streptococcus mitis and Streptococcus sanguinis, Candida albicans and Candida glabrata, and a mixed species, each at 108 cfu/mL were pumped separately into the model for 24 hours to promote microbial adhesion. The resin specimens were then removed, placed in fresh media, and sonicated to dislodge attached microbes. Each suspension (100 μL) was aliquoted and spread on agar plates for colony counting. The resin specimens were also examined under a scanning electron microscope. The interaction between types of specimen and groups of microbes was examined with 2-way ANOVA and then further analysis with Tukey honest significant test and Kruskal-Wallis post hoc tests (α=.05).

    RESULTS: A significant interaction was observed between the 3DP-0, 3DP-60, and HP specimen types and the groups of microbes adhering to the corresponding denture resin specimens (P

  20. Yousof Y, Salleh NM, Yusof F
    J Prosthet Dent, 2019 Jun;121(6):916-921.
    PMID: 30745100 DOI: 10.1016/j.prosdent.2018.09.005
    STATEMENT OF PROBLEM: The 2-color mixing ability test has been recently introduced for objective assessment of masticatory performance. However, the ideal bicolor specimens have not yet been identified, and the color analysis of digital images requires improvement.

    PURPOSE: The purpose of this clinical study was to formulate a custom-made, 2-color chewing gum for the mixing ability test and to develop an image-processing method for color mixing analysis.

    MATERIAL AND METHODS: Specimens of red-green (RG) chewing gum were prepared as a test food. Twenty dentate participants (10 men, 10 women; mean age 21 years) took part in this study. Each participant masticated 1 piece of RG gum for 3, 6, 9, 15, and 25 cycles, and this task was repeated 3 times consecutively (total n=15 for each participant). The boluses were retrieved and flattened to 1-mm-thick wafers and scanned with a flatbed scanner. The digital images were analyzed using ImageJ software equipped with a custom-built plug-in to measure the geometric dispersion (GD) of baseline red segment. The predictive criterion validity of this method was determined by correlating GD to the number of mastication cycles. The hardness and mass of RG chewing gum were measured before and after mastication. Hardness loss (%) and mass loss (%) were then calculated and compared with those of a commercially available chewing gum.

    RESULTS: The 2-way repeated-measures ANOVA with post hoc Bonferroni test showed that GD was able to discriminate among the groups of different numbers of mastication cycles (P