Displaying all 3 publications

Abstract:
Sort:
  1. Agustian J, Kamaruddin AH, Aboul-Enein HY
    Chirality, 2012 May;24(5):356-67.
    PMID: 22517322 DOI: 10.1002/chir.22019
    Because chiral liquid chromatography (LC) could become a powerful tool to estimate racemic atenolol quantity, excellent enantiomeric separation should be produced during data acquisition for satisfactory observation of atenolol concentrations throughout the racemic resolution processes. Selection of chiral LC column and analytical protocol that fulfill demands of the ultra fast LC analysis is essential. This article describes the characteristics of atenolol chromatographic separation that resulted from different resolution media and analytical protocols with the use of a Chiralcel® OD column. The chromatograms showed quite different characteristics of the separation process. The single enantiomer and racemic atenolol could be recognized by the Chiralcel® OD column in less than 20 min. Symmetrical peaks were obtained; however, several protocols produced peaks with wide bases and slanted baselines. Observations showed that efficient enantioresolution of racemic atenolol was obtained at slow mobile phase flow rate, decreased concentration of amine-type modifier but increased alcohol content in mobile phase and highest ultraviolet detection wavelength were required. The optimal ultra fast LC protocol enables to reduce and eliminate the peaks of either the atenolol solvent or the buffers and provided the highest peak intensities of both atenolol enantiomers.
  2. Agustian J, Kamaruddin AH, Aboul-Enein HY
    Chirality, 2017 Jul;29(7):376-385.
    PMID: 28439969 DOI: 10.1002/chir.22702
    As the (R)-enantiomer of racemic atenolol has no β-blocking activity and no lack of side effects, switching from the racemate to the (S)-atenolol is more favorable. Transesterification of racemic atenolol using free enzymes investigated as a resource to resolve the racemate via this method is limited. Screenings of enzyme, medium, and acetyl donor were conducted first to give Pseudomonas fluorescens lipase, tetrahydrofuran, and vinyl acetate. A statistical design of the experiment was then developed using Central Composite Design on some operational factors, which resulted in the conversions of 11.70-61.91% and substrate enantiomeric excess (ee) of 7.31-100%. The quadratic models are acceptable with R2 of 95.13% (conversion) and 89.63% (ee). The predicted values match the observed values reasonably well. Temperature, agitation speed, and substrate molar ratio factor have low effects on conversion and ee, but enzyme loading affects the responses highly. The interaction of temperature-agitation speed and temperature-substrate molar ratio show significant effects on conversion, while temperature-agitation speed, temperature-substrate molar ratio, and agitation speed-substrate molar ratio affect ee highly. Optimum conditions for the use of Pseudomonas fluorescens lipase, tetrahydrofuran, and vinyl acetate were found at 45°C, 175 rpm, 2000 U, and 1:3.6 substrate molar ratio.
  3. Agustian J, Kamaruddin AH, Aboul-Enein HY
    Chirality, 2017 Dec;29(12):847-853.
    PMID: 28963758 DOI: 10.1002/chir.22769
    Kinetic resolution of (R,S)-atenolol is a faster strategy to produce (S)-atenolol. Since this racemate is a less soluble compound, resolution of its ester offers high concentrations in the process. A good analytical method is required to observe the enantiomer concentrations. This paper described application of ultra-fast liquid chromatography on the atenolol ester separation using different resolution media and analytical procedures. Chiralcel OD column resolved the ester. The chromatograms indicated different characteristics of the process. The enantiomers could be recognized by the column in less than 1 (one) hour. Symmetrical peaks were obtained, but several procedures produced peaks with wide bases and slanted baselines. Efficient enantioresolution was obtained at high mobile phase flow rate, decreased concentration of amine-type modifier, but increased alcohol content in the mobile phase. High UV detection wavelength was required. At 1.0 mL/min, the (90/10/0.5) composition resulted α = 1.46 and RS  = 0.9998 that were good separation.
Related Terms
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links