Displaying all 2 publications

Abstract:
Sort:
  1. Kuck JY, Azhar AMN, Wee N, Manikam R
    World J Emerg Med, 2023;14(2):122-127.
    PMID: 36911056 DOI: 10.5847/wjem.j.1920-8642.2023.032
    BACKGROUND: To evaluate the diagnostic accuracy of clinical signs combined with the tongue blade test (TBT) to detect maxillary and mandibular fractures.

    METHODS: A cross-sectional study enrolled patients with maxillary and mandibular injuries in the emergency department. Physical examination and the TBT were performed, followed by radiological imaging (facial X-ray or computed tomography [CT]). The diagnostic accuracy was calculated for individuals and a combination of clinical findings at predicting maxillary and mandibular fractures.

    RESULTS: A total of 98 patients were identified, of whom 31.6% had maxillary fractures and 9.2% had mandibular fractures. The combination of malocclusion, tenderness on palpation and swelling with positive TBT had 100% specificity to detect maxillary and mandibular fractures. In the absence of malocclusion, the combination of tenderness on palpation and swelling with positive TBT produced a specificity of 97.8% for maxillary fracture and a specificity of 96.2% for mandibular fracture. A clinical decision tool consisting of malocclusion, tenderness on palpation, swelling and TBT revealed a specificity of 100% and a positive predictive value of 100%.

    CONCLUSION: The clinical decision tool is potentially useful to rule out mandibular fractures, thus preventing unnecessary radiation exposure.

  2. Yeoh C, Teo A, Azhar AMN, Suann ST, Thum Y, Wong KD, et al.
    J Acute Med, 2019 Sep 01;9(3):128-144.
    PMID: 32995241 DOI: 10.6705/j.jacme.201909_9(3).0005
    Background: Balanced fluids are preferred in initial resuscitation of septic patients based on several recent studies. The Stewart's concept on acid-base balance predicts that high strong ion difference (SID) fluid thus will increase the pH level. To date, the impact of high SID fluid in septic patient with metabolic acidosis remains uncertain. We conducted single center, randomized, double-blind trial to compare the effect of high SID fluid vs. Hartmann's solution on acid-base status in selected sepsis patients in the Emergency Department.

    Methods: Septic patient with hyperlactatemia and metabolic acidosis were randomized to receive either high SID fl uid or Hartmann's solution during initial fl uid resuscitation. The primary outcome measures the pH and bicarbonate levels difference pre- and post- resuscitation.

    Results: One hundred and sixty-two patients underwent randomization, 81 were assigned each to receive high SID fluid or Hartmann's solution. Both groups had similar baseline characteristics. High SID group received 23.5 mL/kg and the Hartmann's group received 22.7 mL/kg (p = 0.360). High SID fluid increased the mean (± SD) pH by 0.107 (± 0.09) vs. Hartmann's solution by 0.014 (± 0.12), p ≤ 0.001. Mean bicarbonate level increased signifi cantly in high SID group compared to Hartmann's (4.30 ± 3.76 vs. 1.25 ± 3.33, p ≤ 0.001). High SID group had higher post resuscitation lactate clearance than Hartmann's group (25.4 ± 28.3% vs. 12.0 ± 34.1%, p = 0.009). Shorter hospital stay was observed in highSID group 8.04 ± 5.96 days vs. Hartmann's group 12.18 ± 12.41 days (p = 0.048). Both groups showed no difference in incidence of pulmonary oedema, acute kidney injury and mortality.

    Conclusions: Initial resuscitation using high SID fluid in selected septic patient improves pH and bicarbonate levels. The high SID group had better post resuscitation lactate clearance and shorter hospital stay.

Related Terms
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)