Displaying all 3 publications

Abstract:
Sort:
  1. Shafie AA, Azman AW
    Public Health, 2015 Sep;129(9):1278-84.
    PMID: 25931434 DOI: 10.1016/j.puhe.2015.03.016
    Food handler's knowledge, attitude and practice regarding food allergies are important to prevent debilitating and sometimes fatal reactions. This study aimed to assess their food allergy knowledge, attitude and practice, which could help to maintain the safety and hygiene of food consumed by the public.
  2. Naeem J, Hamzaid NA, Azman AW, Bijak M
    Biomed Tech (Berl), 2020 Aug 27;65(4):461-468.
    PMID: 32304295 DOI: 10.1515/bmt-2019-0191
    Functional electrical stimulation (FES) has been used to produce force-related activities on the paralyzed muscle among spinal cord injury (SCI) individuals. Early muscle fatigue is an issue in all FES applications. If not properly monitored, overstimulation can occur, which can lead to muscle damage. A real-time mechanomyography (MMG)-based FES system was implemented on the quadriceps muscles of three individuals with SCI to generate an isometric force on both legs. Three threshold drop levels of MMG-root mean square (MMG-RMS) feature (thr50, thr60, and thr70; representing 50%, 60%, and 70% drop from initial MMG-RMS values, respectively) were used to terminate the stimulation session. The mean stimulation time increased when the MMG-RMS drop threshold increased (thr50: 22.7 s, thr60: 25.7 s, and thr70: 27.3 s), indicating longer sessions when lower performance drop was allowed. Moreover, at thr70, the torque dropped below 50% from the initial value in 14 trials, more than at thr50 and thr60. This is a clear indication of muscle fatigue detection using the MMG-RMS value. The stimulation time at thr70 was significantly longer (p = 0.013) than that at thr50. The results demonstrated that a real-time MMG-based FES monitoring system has the potential to prevent the onset of critical muscle fatigue in individuals with SCI in prolonged FES sessions.
  3. Naeem J, Hamzaid NA, Islam MA, Azman AW, Bijak M
    Med Biol Eng Comput, 2019 Jun;57(6):1199-1211.
    PMID: 30687901 DOI: 10.1007/s11517-019-01949-4
    Patients with spinal cord injury (SCI) benefit from muscle training with functional electrical stimulation (FES). For safety reasons and to optimize training outcome, the fatigue state of the target muscle must be monitored. Detection of muscle fatigue from mel frequency cepstral coefficient (MFCC) feature of mechanomyographic (MMG) signal using support vector machine (SVM) classifier is a promising new approach. Five individuals with SCI performed FES cycling exercises for 30 min. MMG signals were recorded on the quadriceps muscle group (rectus femoris (RF), vastus lateralis (VL), vastus medialis (VM)) and categorized into non-fatigued and fatigued muscle contractions for the first and last 10 min of the cycling session. For each subject, a total of 1800 contraction-related MMG signals were used to train the SVM classifier and another 300 signals were used for testing. The average classification accuracy (4-fold) of non-fatigued and fatigued state was 90.7% using MFCC feature, 74.5% using root mean square (RMS), and 88.8% with combined MFCC and RMS features. Inter-subject prediction accuracy suggested training and testing data to be based on a particular subject or large collection of subjects to improve fatigue prediction capacity. Graphical abstract ᅟ.
Related Terms
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links