Displaying all 4 publications

Abstract:
Sort:
  1. Blair GW, Appleton JP, Flaherty K, Doubal F, Sprigg N, Dooley R, et al.
    EClinicalMedicine, 2019 04 24;11:34-43.
    PMID: 31317131 DOI: 10.1016/j.eclinm.2019.04.001
    Background: Lacunar stroke, a frequent clinical manifestation of small vessel disease (SVD), differs pathologically from other ischaemic stroke subtypes and has no specific long-term secondary prevention. Licenced drugs, isosorbide mononitrate (ISMN) and cilostazol, have relevant actions to prevent SVD progression.

    Methods: We recruited independent patients with clinically confirmed lacunar ischaemic stroke without cognitive impairment to a prospective randomised clinical trial, LACunar Intervention-1 (LACI-1). We randomised patients using a central web-based system, 1:1:1:1 with minimisation, to masked ISMN 25 mg bd, cilostazol 100 mg bd, both ISMN and cilostazol started immediately, or both with start delayed. We escalated doses to target over two weeks, sustained for eight weeks. Primary outcome was the proportion achieving target dose. Secondary outcomes included symptoms, safety (haemorrhage, recurrent vascular events), cognition, haematology, vascular function, and neuroimaging. LACI-1 was powered (80%, alpha 0.05) to detect 35% (90% versus 55%) difference between the proportion reaching target dose on one versus both drugs at 55 patients. Registration ISRCTN12580546.

    Findings: LACI-1 enrolled 57 participants between March 2016 and August 2017: 18 (32%) females, mean age 66 (SD 11, range 40-85) years, onset-randomisation 203 (range 6-920) days. Most achieved full (64%) or over half (87%) dose, with no difference between cilostazol vs ISMN, single vs dual drugs. Headache and palpitations increased initially then declined similarly with dual versus single drugs. There was no between-group difference in BP, pulse-wave velocity, haemoglobin or platelet function, but pulse rate was higher (mean difference, MD, 6.4, 95%CI 1.2-11.7, p = 0.02), platelet count higher (MD 35.7, 95%CI 2.8, 68.7, p = 0.03) and white matter hyperintensities reduced more (Chi-square p = 0.007) with cilostazol versus no cilostazol.

    Interpretation: Cilostazol and ISMN are well tolerated when the dose is escalated, without safety concerns, in patients with lacunar stroke. Larger trials with longer term follow-up are justified.

    Funding: Alzheimer's Society (AS-PG-14-033).

  2. Blair GW, Appleton JP, Law ZK, Doubal F, Flaherty K, Dooley R, et al.
    Int J Stroke, 2018 07;13(5):530-538.
    PMID: 28906205 DOI: 10.1177/1747493017731947
    Rationale The pathophysiology of most lacunar stroke, a form of small vessel disease, is thought to differ from large artery atherothrombo- or cardio-embolic stroke. Licensed drugs, isosorbide mononitrate and cilostazol, have promising mechanisms of action to support their testing to prevent stroke recurrence, cognitive impairment, or radiological progression after lacunar stroke. Aim LACI-1 will assess the tolerability, safety, and efficacy, by dose, of isosorbide mononitrate and cilostazol, alone and in combination, in patients with ischemic lacunar stroke. Sample size A sample of 60 provides 80+% power (significance 0.05) to detect a difference of 35% (90% versus 55%) between those reaching target dose on one versus both drugs. Methods and design LACI-1 is a phase IIa partial factorial, dose-escalation, prospective, randomized, open label, blinded endpoint trial. Participants are randomized to isosorbide mononitrate and/or cilostazol for 11 weeks with dose escalation to target as tolerated in two centers (Edinburgh, Nottingham). At three visits, tolerability, safety, blood pressure, pulse wave velocity, and platelet function are assessed, plus magnetic resonance imaging to assess cerebrovascular reactivity in a subgroup. Study outcomes Primary: proportion of patients completing study achieving target maximum dose. Secondary symptoms whilst taking medications; safety (hemorrhage, recurrent vascular events, falls); blood pressure, platelet function, arterial stiffness, and cerebrovascular reactivity. Discussion This study will inform the design of a larger phase III trial of isosorbide mononitrate and cilostazol in lacunar stroke, whilst providing data on the drugs' effects on vascular and platelet function. Trial registration ISRCTN (ISRCTN12580546) and EudraCT (2015-001953-33).
  3. Aad G, Abbott B, Abeling K, Abicht NJ, Abidi SH, Aboulhorma A, et al.
    Phys Rev Lett, 2024 Jan 12;132(2):021803.
    PMID: 38277607 DOI: 10.1103/PhysRevLett.132.021803
    The first evidence for the Higgs boson decay to a Z boson and a photon is presented, with a statistical significance of 3.4 standard deviations. The result is derived from a combined analysis of the searches performed by the ATLAS and CMS Collaborations with proton-proton collision datasets collected at the CERN Large Hadron Collider (LHC) from 2015 to 2018. These correspond to integrated luminosities of around 140  fb^{-1} for each experiment, at a center-of-mass energy of 13 TeV. The measured signal yield is 2.2±0.7 times the standard model prediction, and agrees with the theoretical expectation within 1.9 standard deviations.
  4. Hayrapetyan A, Tumasyan A, Adam W, Andrejkovic JW, Bergauer T, Chatterjee S, et al.
    Phys Rev Lett, 2024 Jun 28;132(26):261902.
    PMID: 38996325 DOI: 10.1103/PhysRevLett.132.261902
    A combination of fifteen top quark mass measurements performed by the ATLAS and CMS experiments at the LHC is presented. The datasets used correspond to an integrated luminosity of up to 5 and 20  fb^{-1} of proton-proton collisions at center-of-mass energies of 7 and 8 TeV, respectively. The combination includes measurements in top quark pair events that exploit both the semileptonic and hadronic decays of the top quark, and a measurement using events enriched in single top quark production via the electroweak t channel. The combination accounts for the correlations between measurements and achieves an improvement in the total uncertainty of 31% relative to the most precise input measurement. The result is m_{t}=172.52±0.14(stat)±0.30(syst)  GeV, with a total uncertainty of 0.33 GeV.
Related Terms
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links