Displaying all 2 publications

Abstract:
Sort:
  1. Atan R, Peck L, Visvanathan K, Skinner N, Eastwood G, Bellomo R, et al.
    Int J Artif Organs, 2016 Nov 11;39(9):479-486.
    PMID: 27834446 DOI: 10.5301/ijao.5000527
    PURPOSE: To study the effects of continuous veno-venous hemofiltration (CVVH) with high cut-off filters (CVVH-HCO) on plasma cytokine levels, sieving coefficient and clearance compared to CVVH using standard filters (CVVH-Std) in a nested cohort within a double-blind randomized controlled trial in severe acute kidney injury (AKI) patients.

    METHODS: We measured plasma and post-filter levels of IL-6, TNF-alpha, IL-8, IL-1 beta, RANTES, IL-10, IFN-gamma and IFN-alpha in both study groups. We also measured cytokine levels in the ultrafiltrate and calculated sieving coefficients and clearances.

    RESULTS: By 72 hours of treatment, IL-6 had decreased during both treatments (p = 0.009 and 0.005 respectively). In contrast, IL-10 had decreased with CVVH-Std (p = 0.03) but not CVVH-HCO (p = 0.135). None of the other cytokines showed changes over time. There were also no significant between group differences in plasma levels for each cytokine over the 72-hour treatment period. For all cytokines combined, however, the median sieving coefficient was higher for CVVH-HCO (0.31 vs. 0.16; p = 0.042) as was the mass removal rate by ultrafiltration (p = 0.027). While overall combined cytokine levels had fallen to 62.2% of baseline at 72 hours for CVVH-HCO (p<0.0001) and to 75.9% of baseline with CVVH-Std (p = 0.008) there were no between group differences.

    CONCLUSIONS: CVVH-HCO achieved greater combined sieving coefficient and mass removal rate by ultrafiltration for a group of key cytokines than CVVH-Std. However, this effect did not differentially lower their plasma level over the first 72 hours. Our study does not support the use of CVVH-HCO to lower cytokines in critically ill patients with AKI.

  2. Atan R, Virzi GM, Peck L, Ramadas A, Brocca A, Eastwood G, et al.
    Blood Purif., 2014;37(4):296-303.
    PMID: 25096908 DOI: 10.1159/000363220
    To measure plasma pro-apoptotic and pro-necrotic activity in severe acute kidney injury (AKI) patients within a randomized controlled trial of continuous veno-venous hemofiltration with high cut-off filters (CVVH-HCO) versus standard filters (CVVH-Std).
Related Terms
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links