Displaying all 2 publications

Abstract:
Sort:
  1. Bebakar WM, Chaykin L, Hersløv ML, Rasmussen S
    Diabetes Ther, 2017 Feb;8(1):197-205.
    PMID: 27853981 DOI: 10.1007/s13300-016-0213-8
    INTRODUCTION: In a preceding trial comparing two different titration schemes, insulin degludec/insulin aspart (IDegAsp) showed good efficacy for achieving HbA1c <7% when administered twice daily (BID) in patients with uncontrolled type 2 diabetes (T2D). However, poor glycemic control persisted in a minority of patients. The current exploratory trial investigated the efficacy and safety of intensifying IDegAsp BID treatment in these patients by either adding a once-daily (OD) bolus injection of insulin aspart (IAsp) or by switching to a basal-bolus regimen of insulin degludec (IDeg) plus IAsp taken three times a day (TID).

    METHOD: A 26-week, randomized, open-label, phase 3b, treat-to-target trial in which 40 patients with T2D who had not reached target HbA1c ≤7.0% following previous 26-week treatment intensification with IDegAsp BID ±3 oral antidiabetic agents (OADs) were randomized (1:1) to receive IDegAsp BID + IAsp OD (n = 20) or IDeg OD + IAsp TID (n = 20).

    RESULTS: Mean baseline HbA1c was 7.9% in the IDegAsp BID + IAsp OD group and 7.7% in the IDeg OD + IAsp TID group. After 26 weeks, the estimated mean change in HbA1c from baseline was 0.05% points in the IDegAsp BID + IAsp OD group and -0.49% points for IDeg OD + IAsp TID: estimated treatment difference (ETD) [95% confidence interval] 0.54% [0.09; 0.99], p = 0.021. Few achieved HbA1c <7% in IDegAsp BID + IAsp OD (four patients) and IDeg OD + IAsp TID groups (five patients). Fasting plasma glucose, hypoglycemia, and adverse events were similar between groups.

    CONCLUSION: When used as intensification regimens in patients who failed to achieve target HbA1c during 26-week IDegAsp BID treatment, HbA1c improvements were numerically greater with IDeg OD + IAsp TID compared with IDegAsp BID + IAsp OD. No new safety issues were identified. However, the small, selective sample means clinical generalizations should be made with caution.

    FUNDING: Novo Nordisk. CLINICALTRIALS.

    GOV IDENTIFIER: NCT01814137.

  2. Park SW, Bebakar WM, Hernandez PG, Macura S, Hersløv ML, de la Rosa R
    Diabet Med, 2017 02;34(2):174-179.
    PMID: 26773557 DOI: 10.1111/dme.13069
    AIMS: To compare the efficacy and safety of two titration algorithms for insulin degludec/insulin aspart (IDegAsp) administered once daily with metformin in participants with insulin-naïve Type 2 diabetes mellitus.

    METHODS: This open-label, parallel-group, 26-week, multicentre, treat-to-target trial, randomly allocated participants (1:1) to two titration arms. The Simple algorithm titrated IDegAsp twice weekly based on a single pre-breakfast self-monitored plasma glucose (SMPG) measurement. The Stepwise algorithm titrated IDegAsp once weekly based on the lowest of three consecutive pre-breakfast SMPG measurements. In both groups, IDegAsp once daily was titrated to pre-breakfast plasma glucose values of 4.0-5.0 mmol/l. Primary endpoint was change from baseline in HbA1c (%) after 26 weeks.

    RESULTS: Change in HbA1c at Week 26 was IDegAspSimple -14.6 mmol/mol (-1.3%) (to 52.4 mmol/mol; 6.9%) and IDegAspStepwise -11.9 mmol/mol (-1.1%) (to 54.7 mmol/mol; 7.2%). The estimated between-group treatment difference was -1.97 mmol/mol [95% confidence interval (CI) -4.1, 0.2] (-0.2%, 95% CI -0.4, 0.02), confirming the non-inferiority of IDegAspSimple to IDegAspStepwise (non-inferiority limit of ≤ 0.4%). Mean reduction in fasting plasma glucose and 8-point SMPG profiles were similar between groups. Rates of confirmed hypoglycaemia were lower for IDegAspStepwise [2.1 per patient years of exposure (PYE)] vs. IDegAspSimple (3.3 PYE) (estimated rate ratio IDegAspSimple /IDegAspStepwise 1.8; 95% CI 1.1, 2.9). Nocturnal hypoglycaemia rates were similar between groups. No severe hypoglycaemic events were reported.

    CONCLUSIONS: In participants with insulin-naïve Type 2 diabetes mellitus, the IDegAspSimple titration algorithm improved HbA1c levels as effectively as a Stepwise titration algorithm. Hypoglycaemia rates were lower in the Stepwise arm.

Related Terms
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links