It is important to assess indoor air quality in school classrooms where the air quality may significantly influence school children's health and performance. This study aims to determine the concentrations of PM2.5 and dust chemical compositions in indoor and outdoor school classroom located in Kuala Lumpur City Centre. The PM2.5 concentration was measured from 19th September 2017-16th February 2018 using an optical PM2.5 sensor. Indoor and outdoor dust was also collected from the school classrooms and ion and trace metal concentrations were analysed using ion chromatography (IC) and inductively couple plasma-mass spectrometry (ICP-MS) respectively. This study showed that the average indoor and outdoor 24 h PM2.5 was 11.2 ± 0.45 µg m-3 and 11.4 ± 0.44 µg m-3 respectively. The 8 h PM2.5 concentration ranged between 3.2 and 28 µg m-3 for indoor and 3.2 and 19 µg m-3 for outdoor classrooms. The highest ion concentration in indoor dust was Ca2+ with an average concentration of 38.5 ± 35.0 µg g-1 while for outdoor dust SO42- recorded the highest ion concentration with an average concentration of 30.6 ± 9.37 µg g-1. Dominant trace metals in both indoor and outdoor dust were Al, Fe and Zn. Principle component analysis-multiple linear regression (PCA-MLR) demonstrated that the major source of indoor dust was road dust (69%), while soil dominated the outdoor dust (74%). Health risk assessment showed that the hazard quotient (HQ) value for non-carcinogenic trace metals was
It is important to have good indoor air quality, especially in indoor office environments, in order to enhance productivity and maintain good work performance. This study investigated the effects of indoor office activities on particulate matter of less than 2.5 μm (PM2.5) and ozone (O3) concentrations, assessing their potential impact on human health. Measurements of indoor PM2.5 and O3 concentrations were taken every 24 h during the working days in five office environments located in a semi-urban area. As a comparison, the outdoor concentrations were derived from the nearest Continuous Air Quality Monitoring Station. The results showed that the average 24 h of indoor and outdoor PM2.5 concentrations were 3.24 ± 0.82 μg m-3 and 17.4 ± 3.58 μg m-3 respectively, while for O3 they were 4.75 ± 4.52 ppb and 21.5 ± 5.22 ppb respectively. During working hours, the range of PM2.5 concentrations were 1.00 μg m-3 to 6.10 μg m-3 while for O3 they were 0.10 ppb to 38.0 ppb. The indoor to outdoor ratio (I/O) for PM2.5 and O3 was <1, thus indicating a low infiltration of outdoor sources. The value of the hazard quotient (HQ) for all sampling buildings was <1 for both chronic and acute exposures, indicating that the non-carcinogenic risks are negligible. Higher total cancer risk (CR) value for outdoors (2.67E-03) was observed compared to indoors (4.95E-04) under chronic exposure while the CR value for acute exposure exceeded 1.0E-04, thus suggesting a carcinogenic PM2.5 risk for both the indoor and outdoor environments. The results of this study suggest that office activities, such as printing and photocopying, affect indoor O3 concentrations while PM2.5 concentrations are impacted by indoor-related contributions.