Displaying all 2 publications

Abstract:
Sort:
  1. Sthaneshwar P, Lai LC, Raja Azzidin RE, Mohd Hussain B, Anas SS, Supremaniam S, et al.
    Malays J Pathol, 2021 Apr;43(1):41-48.
    PMID: 33903304
    INTRODUCTION: The Malaysian Association of Clinical Biochemists (MACB) established a Task Force for Chronic Kidney Disease. A survey was undertaken by the Task Force on the reporting of estimated glomerular filtration rate (eGFR) and urine albumin by hospital laboratories in Malaysia in both the government and private sectors.

    MATERIALS AND METHODS: An e-mail invitation to participate in an online survey was sent to hospital laboratories in Malaysia (n=140). Questions regarding methods for measuring creatinine, equations for calculating eGFR, eGFR reporting, the terminology used in reporting urine albumin, types of samples and the cut-off values used for normal albuminuria.

    RESULTS: A total of 42/140 (30%) laboratories answered the questionnaire. The prevalent method used for serum creatinine measurement was the Jaffé method (88.1%) traceable to isotope-dilution mass spectrometry. eGFR was reported along with serum creatinine by 61.9% of laboratories while 33.3% of laboratories report eGFR on request. The formula used for eGFR reporting was mainly MDRD (64.3%) and results were reported as exact numbers even when the eGFR was <60 ml/min/1.73m2. The term microalbumin is still used by 83.3% of laboratories. There is a large heterogeneity among the labs regarding the type of sample recommended for measuring urine albumin, reference interval and reporting units.

    CONCLUSION: It is evident that the laboratory assessment of chronic kidney disease in Malaysia is not standardised. It is essential to provide a national framework for standardised reporting of eGFR and urine albumin. Recommendations developed by the MACB CKD Task Force, if adopted by all laboratories, will lead to a reduction in this variability.

  2. Hariri A, Mohamad Noor N, Paiman NA, Ahmad Zaidi AM, Zainal Bakri SF
    Int J Occup Saf Ergon, 2018 Dec;24(4):646-651.
    PMID: 28849717 DOI: 10.1080/10803548.2017.1368950
    Welding operations are rarely conducted in an air-conditioned room. However, a company would set its welding operations in an air-conditioned room to maintain the humidity level needed to reduce hydrogen cracks in the specimen being welded. This study intended to assess the exposure to metal elements in the welders' breathing zone and toenail samples. Heavy metal concentration was analysed using inductively coupled plasma mass spectrometry. The lung function test was also conducted and analysed using statistical approaches. Chromium and manganese concentrations in the breathing zone exceeded the permissible exposure limit stipulated by Malaysian regulations. A similar trend was obtained in the concentration of heavy metals in the breathing zone air sampling and in the welders' toenails. Although there was no statistically significant decrease in the lung function of welders, it is suggested that exposure control through engineering and administrative approaches should be considered for workplace safety and health improvement.
Related Terms
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links