Displaying all 3 publications

Abstract:
Sort:
  1. Awan MJ, Bilal MH, Yasin A, Nobanee H, Khan NS, Zain AM
    Int J Environ Res Public Health, 2021 Sep 27;18(19).
    PMID: 34639450 DOI: 10.3390/ijerph181910147
    Coronavirus disease (COVID-19) spreads from one person to another rapidly. A recently discovered coronavirus causes it. COVID-19 has proven to be challenging to detect and cure at an early stage all over the world. Patients showing symptoms of COVID-19 are resulting in hospitals becoming overcrowded, which is becoming a significant challenge. Deep learning's contribution to big data medical research has been enormously beneficial, offering new avenues and possibilities for illness diagnosis techniques. To counteract the COVID-19 outbreak, researchers must create a classifier distinguishing between positive and negative corona-positive X-ray pictures. In this paper, the Apache Spark system has been utilized as an extensive data framework and applied a Deep Transfer Learning (DTL) method using Convolutional Neural Network (CNN) three architectures -InceptionV3, ResNet50, and VGG19-on COVID-19 chest X-ray images. The three models are evaluated in two classes, COVID-19 and normal X-ray images, with 100 percent accuracy. But in COVID/Normal/pneumonia, detection accuracy was 97 percent for the inceptionV3 model, 98.55 percent for the ResNet50 Model, and 98.55 percent for the VGG19 model, respectively.
  2. Awan MJ, Mohd Rahim MS, Salim N, Nobanee H, Asif AA, Attiq MO
    PeerJ Comput Sci, 2023;9:e1483.
    PMID: 37547408 DOI: 10.7717/peerj-cs.1483
    Anterior cruciate ligament (ACL) tears are a common knee injury that can have serious consequences and require medical intervention. Magnetic resonance imaging (MRI) is the preferred method for ACL tear diagnosis. However, manual segmentation of the ACL in MRI images is prone to human error and can be time-consuming. This study presents a new approach that uses deep learning technique for localizing the ACL tear region in MRI images. The proposed multi-scale guided attention-based context aggregation (MGACA) method applies attention mechanisms at different scales within the DeepLabv3+ architecture to aggregate context information and achieve enhanced localization results. The model was trained and evaluated on a dataset of 917 knee MRI images, resulting in 15265 slices, obtaining state-of-the-art results with accuracy scores of 98.63%, intersection over union (IOU) scores of 95.39%, Dice coefficient scores (DCS) of 97.64%, recall scores of 97.5%, precision scores of 98.21%, and F1 Scores of 97.86% on validation set data. Moreover, our method performed well in terms of loss values, with binary cross entropy combined with Dice loss (BCE_Dice_loss) and Dice_loss values of 0.0564 and 0.0236, respectively, on the validation set. The findings suggest that MGACA provides an accurate and efficient solution for automating the localization of ACL in knee MRI images, surpassing other state-of-the-art models in terms of accuracy and loss values. However, in order to improve robustness of the approach and assess its performance on larger data sets, further research is needed.
  3. Awan MJ, Mohd Rahim MS, Salim N, Rehman A, Nobanee H
    J Healthc Eng, 2022;2022:2550120.
    PMID: 35444781 DOI: 10.1155/2022/2550120
    In recent times, knee joint pains have become severe enough to make daily tasks difficult. Knee osteoarthritis is a type of arthritis and a leading cause of disability worldwide. The middle of the knee contains a vital portion, the anterior cruciate ligament (ACL). It is necessary to diagnose the ACL ruptured tears early to avoid surgery. The study aimed to perform a comparative analysis of machine learning models to identify the condition of three ACL tears. In contrast to previous studies, this study also considers imbalanced data distributions as machine learning techniques struggle to deal with this problem. The paper applied and analyzed four machine learning classification models, namely, random forest (RF), categorical boosting (Cat Boost), light gradient boosting machines (LGBM), and highly randomized classifier (ETC) on the balanced, structured dataset of ACL. After oversampling a hyperparameter adjustment, the above four models have achieved an average accuracy of 95.72%, 94.98%, 94.98%, and 98.26%. There are 2070 observations and eight features in the collection of three diagnosis ACL classes after oversampling. The area under curve value was approximately 0.998, respectively. Experiments were performed using twelve machine learning algorithms with imbalanced and balanced datasets. However, the accuracy of the imbalanced dataset has remained under 76% for all twelve models. After oversampling, the proposed model may contribute to the investigation of ACL tears on magnetic resonance imaging and other knee ligaments efficiently and automatically without involving radiologists.
Related Terms
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links