Displaying all 3 publications

Abstract:
Sort:
  1. Jayaranee S, Prathiba R, Vasanthi N, Lopez CG
    Malays J Pathol, 2002 Jun;24(1):59-66.
    PMID: 16329557
    The purpose of this study is to determine the efficiency of blood utilization for elective surgery at the University of Malaya Medical Centre (UMMC). A similar study conducted six years earlier in the same unit resulted in the introduction and implementation in December 1997 of the local Maximum Surgical Blood Order Schedule (MSBOS) and the Group Screen and Hold (GSH) procedure instead of a full crossmatch. This paper compares the findings of the current study with that conducted earlier.
  2. Prathiba R, Lopez CG, Usin FM
    Malays J Pathol, 2002 Dec;24(2):95-8.
    PMID: 12887167
    The Mi III phenotype of the Miltenberger subsystem (or GP Mur) is relatively common in Southeast Asia especially along the south-east coast lines of China and Taiwan. The term anti-"Mia" describes antibodies that react with the Mi III phenotype. Since the Peninsula Malaysian population is a multiethnic one with a significant proportion of Chinese, a study was conducted into the prevalence of anti-"Mia" in patients from its 3 major ethnic groups--Chinese, Malays and Indians, as well as the GP Mur phenotype in blood donors (healthy individuals). Blood samples from 33,716 patients (general and antenatal) were screened for anti-"Mia" from January 1999 to December 2000. The investigation for the GP Mur phenotype representing the corresponding sensitizing antigen complex was carried out in 655 blood donors. Serum anti-"Mia" antibody was found to be the third most commonly occurring antibody detected in our patients and was found in all the ethnic groups. The antibody was detected in 0.2% of 33,716 antenatal and general patients with a prevalence in Chinese of 0.3%, Malay 0.2% and Indian 0.2%. The detection of these antibodies in the ethnic groups other than the Chinese is a noteworthy finding as such information is not well documented. The GP Mur red cell phenotype was detected in 15/306 (4.9%) of Chinese blood donors, a lower prevalence than in Chinese populations in other countries in the region. More significant was its detection in the Malays (2.8%) and the Indians (3.0%). Because of the many reports of clinical problems associated with the "Mia" antibody including the causation of fetal hydrops and haemolytic transfusion reactions, it is warranted that the GP Mur red cells be included in screening panels for group and screen procedures in countries with a significant Asian population.
  3. Prathiba R, Jayaranee S, Ramesh JC, Lopez CG, Vasanthi N
    Malays J Pathol, 2001 Jun;23(1):41-6.
    PMID: 16329547
    This paper evaluates the practice of fresh frozen plasma (FFP) transfusion at the University Hospital, Kuala Lumpur, and analyses its usage by the various clinical departments. The aim of this study is to identify where it is inappropriately used and the clinical indications in which such misuse is common. A retrospective analysis of the blood bank request forms and work sheets during a 6-month period between January 1998 and June 1998 formed the basis of this study. Overall, 40% of 2665 units transfused were considered appropriate. However, out of the 931 episodes of FFP transfusions only 31% were for appropriate indications. The average FFP requirement when used for appropriate indication was about 4 units per episode, whereas for inappropriate indication it was 2.5 units per episode. Inappropriate use in terms of the number of units was highest by the surgical services (68%) and Orthopaedics (64%), while the Department of Paediatrics had the lowest incidence of inappropriate use (40%). When Paediatrics was used as the benchmark, the incidence of inappropriate use by other departments was significantly higher (p < 0.01). As for FFP usage in common clinical indications, there was a high incidence of inappropriate use in burns (82%), perioperative period (73%), cardiac surgery (68%), massive bleeding (62%) and trauma (60%). The findings in this study, specifically the use of FFP for volume support in trauma, massive bleeding and burns, routine requests without identified indication in cardiac bypass surgery, and prophylactic use in the perioperative period can be the basis for recommendations to minimize the inappropriate use of FFP in the future.
Related Terms
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links