Displaying all 2 publications

Abstract:
Sort:
  1. Donnan F, Senarathna SMDKG, Ware B, Rawlins MDM, Dontham C, Chuang VTG, et al.
    Aust N Z J Obstet Gynaecol, 2020 06;60(3):344-349.
    PMID: 31512230 DOI: 10.1111/ajo.13046
    BACKGROUND: Postpartum haemorrhage (PPH) kits containing uterotonics are used on obstetric units for the timely management of PPH. Visible discolouration of ergometrine and ergometrine-oxytocin injections was observed in PPH kits stored in medical refrigerators on the obstetric unit at our hospital.

    AIM: To investigate the stability of ergometrine and ergometrine-oxytocin injections in PPH kits under simulated clinical storage conditions and to determine the potency of ampoules quarantined from PPH kits on our obstetric unit.

    MATERIAL AND METHODS: Ergometrine and ergometrine-oxytocin injection ampoules were stored exposed to and protected from light at 4°C and room temperature (25°C) for up to three months, and assayed by high-performance liquid chromatography. Stability was based on the time for the ergometrine or oxytocin concentration to fall to 90% of the original concentration (t90 ). The potency of quarantined discoloured ampoules also was determined.

    RESULTS: Ergometrine was stable at both temperatures for >6 months, when stored protected from light in simulated clinical conditions. When exposed to light, ergometrine was stable for approximately 4 days at 25°C and 10 days at 4°C. Discoloured ergometrine and ergometrine-oxytocin injection ampoules were found to be <90% of the nominal concentration.

    CONCLUSION: Stability of ergometrine in PPH kits is largely unaffected by temperature fluctuations (at 4°C and 25°C) over 6 months when protected from light. Ergometrine and ergometrine-oxytocin ampoules should be inspected prior to use and any discoloured ampoules discarded.

  2. Hand RM, Senarathna SMDKG, Page-Sharp M, Gray K, Sika-Paotonu D, Sheel M, et al.
    Pharmacol Res Perspect, 2020 12;8(6):e00668.
    PMID: 33090729 DOI: 10.1002/prp2.668
    Benzathine penicillin G (BPG) is used as first-line treatment for most forms of syphilis and as secondary prophylaxis against rheumatic heart disease (RHD). Perceptions that poor quality of BPG is linked to reported adverse effects and therapeutic failure may impact syphilis and RHD control programs. Clinical networks and web-based advertising were used to obtain vials of BPG from a wide range of countries. The quality of BPG was assessed using a high performance liquid chromatography assay capable of detecting relevant impurities and degradation products. Tests for water content, presence of heavy metals and physical characteristics of BPG, including particle size analysis and optical microscopy, also were conducted. Thirty-five batches of BPG were sourced from 16 countries across 4 WHO regions. All batches passed the US Pharmacopeia requirements for BPG injection (content), with no evidence of breakdown products or other detected contaminants. Water content and heavy metal analysis (n = 11) indicated adherence to regulatory standards and Good Manufacturing Practice. Particle size analysis (n = 20) found two batches with aggregated particles (>400 µm) that were dispersed following sonication. Current batches of BPG were of satisfactory pharmaceutical quality but aggregated particles were found in a modest proportion of samples. Future studies should focus on the physical characteristics of BPG which may contribute to variations in plasma penicillin concentrations an observed needle blockages in clinical practice. Pharmacopeial monographs could be revised to include standards on particle size and crystal morphology of BPG.
Related Terms
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links