Displaying all 3 publications

Abstract:
Sort:
  1. Lai NM, Taylor JE, Tan K, Choo YM, Ahmad Kamar A, Muhamad NA
    Cochrane Database Syst Rev, 2016 Mar 23;3:CD011082.
    PMID: 27007217 DOI: 10.1002/14651858.CD011082.pub2
    BACKGROUND: Central venous catheters (CVCs) provide secured venous access in neonates. Antimicrobial dressings applied over the CVC sites have been proposed to reduce catheter-related blood stream infection (CRBSI) by decreasing colonisation. However, there may be concerns on the local and systemic adverse effects of these dressings in neonates.

    OBJECTIVES: We assessed the effectiveness and safety of antimicrobial (antiseptic or antibiotic) dressings in reducing CVC-related infections in newborn infants. Had there been relevant data, we would have evaluated the effects of antimicrobial dressings in different subgroups, including infants who received different types of CVCs, infants who required CVC for different durations, infants with CVCs with and without other antimicrobial modifications, and infants who received an antimicrobial dressing with and without a clearly defined co-intervention.

    SEARCH METHODS: We used the standard search strategy of the Cochrane Neonatal Review Group (CNRG). We searched the Cochrane Central Register of Controlled Trials (The Cochrane Library 2015, Issue 9), MEDLINE (PubMed), EMBASE (EBCHOST), CINAHL and references cited in our short-listed articles using keywords and MeSH headings, up to September 2015.

    SELECTION CRITERIA: We included randomised controlled trials that compared an antimicrobial CVC dressing against no dressing or another dressing in newborn infants.

    DATA COLLECTION AND ANALYSIS: We extracted data using the standard methods of the CNRG. Two review authors independently assessed the eligibility and risk of bias of the retrieved records. We expressed our results using risk difference (RD) and risk ratio (RR) with 95% confidence intervals (CIs).

    MAIN RESULTS: Out of 173 articles screened, three studies were included. There were two comparisons: chlorhexidine dressing following alcohol cleansing versus polyurethane dressing following povidone-iodine cleansing (one study); and silver-alginate patch versus control (two studies). A total of 855 infants from level III neonatal intensive care units (NICUs) were evaluated, 705 of whom were from a single study. All studies were at high risk of bias for blinding of care personnel or unclear risk of bias for blinding of outcome assessors. There was moderate-quality evidence for all major outcomes.The single study comparing chlorhexidine dressing/alcohol cleansing against polyurethane dressing/povidone-iodine cleansing showed no significant difference in the risk of CRBSI (RR 1.18, 95% CI 0.53 to 2.65; RD 0.01, 95% CI -0.02 to 0.03; 655 infants, moderate-quality evidence) and sepsis without a source (RR 1.06, 95% CI 0.75 to 1.52; RD 0.01, 95% CI -0.04 to 0.06; 705 infants, moderate-quality evidence). There was a significant reduction in the risk of catheter colonisation favouring chlorhexidine dressing/alcohol cleansing group (RR 0.62, 95% CI 0.45 to 0.86; RD -0.09, 95% CI -0.15 to -0.03; number needed to treat for an additional beneficial outcome (NNTB) 11, 95% CI 7 to 33; 655 infants, moderate-quality evidence). However, infants in the chlorhexidine dressing/alcohol cleansing group were significantly more likely to develop contact dermatitis, with 19 infants in the chlorhexidine dressing/alcohol cleansing group having developed contact dermatitis compared to none in the polyurethane dressing/povidone-iodine cleansing group (RR 43.06, 95% CI 2.61 to 710.44; RD 0.06, 95% CI 0.03 to 0.08; number needed to treat for an additional harmful outcome (NNTH) 17, 95% CI 13 to 33; 705 infants, moderate-quality evidence). The roles of chlorhexidine dressing in the outcomes reported were unclear, as the two assigned groups received different co-interventions in the form of different skin cleansing agents prior to catheter insertion and during each dressing change.In the other comparison, silver-alginate patch versus control, the data for CRBSI were analysed separately in two subgroups as the two included studies reported the outcome using different denominators: one using infants and another using catheters. There were no significant differences between infants who received silver-alginate patch against infants who received standard line dressing in CRBSI, whether expressed as the number of infants (RR 0.50, 95% CI 0.14 to 1.78; RD -0.12, 95% CI -0.33 to 0.09; 1 study, 50 participants, moderate-quality evidence) or as the number of catheters (RR 0.72, 95% CI 0.27 to 1.89; RD -0.05, 95% CI -0.20 to 0.10; 1 study, 118 participants, moderate-quality evidence). There was also no significant difference between the two groups in mortality (RR 0.55, 95% CI 0.15 to 2.05; RD -0.04, 95% CI -0.13 to 0.05; two studies, 150 infants, I² = 0%, moderate-quality evidence). No adverse skin reaction was recorded in either group.

    AUTHORS' CONCLUSIONS: Based on moderate-quality evidence, chlorhexidine dressing/alcohol skin cleansing reduced catheter colonisation, but made no significant difference in major outcomes like sepsis and CRBSI compared to polyurethane dressing/povidone-iodine cleansing. Chlorhexidine dressing/alcohol cleansing posed a substantial risk of contact dermatitis in preterm infants, although it was unclear whether this was contributed mainly by the dressing material or the cleansing agent. While silver-alginate patch appeared safe, evidence is still insufficient for a recommendation in practice. Future research that evaluates antimicrobial dressing should ensure blinding of caregivers and outcome assessors and ensure that all participants receive the same co-interventions, such as the skin cleansing agent. Major outcomes like sepsis, CRBSI and mortality should be assessed in infants of different gestation and birth weight.

  2. Lai NM, Lai NA, O'Riordan E, Chaiyakunapruk N, Taylor JE, Tan K
    Cochrane Database Syst Rev, 2016 Jul 13;7:CD010140.
    PMID: 27410189 DOI: 10.1002/14651858.CD010140.pub2
    BACKGROUND: The central venous catheter (CVC) is a device used for many functions, including monitoring haemodynamic indicators and administering intravenous medications, fluids, blood products and parenteral nutrition. However, as a foreign object, it is susceptible to colonisation by micro-organisms, which may lead to catheter-related blood stream infection (BSI) and in turn, increased mortality, morbidities and health care costs.

    OBJECTIVES: To assess the effects of skin antisepsis as part of CVC care for reducing catheter-related BSIs, catheter colonisation, and patient mortality and morbidities.

    SEARCH METHODS: In May 2016 we searched: The Cochrane Wounds Specialised Register; The Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library); Ovid MEDLINE (including In-Process & Other Non-Indexed Citations and Epub Ahead of Print); Ovid EMBASE and EBSCO CINAHL Plus. We also searched clinical trial registries for ongoing and unpublished studies. There were no restrictions with respect to language, date of publication or study setting.

    SELECTION CRITERIA: We included randomised controlled trials (RCTs) that assessed any type of skin antiseptic agent used either alone or in combination, compared with one or more other skin antiseptic agent(s), placebo or no skin antisepsis in patients with a CVC in place.

    DATA COLLECTION AND ANALYSIS: Two authors independently assessed the studies for their eligibility, extracted data and assessed risk of bias. We expressed our results in terms of risk ratio (RR), absolute risk reduction (ARR) and number need to treat for an additional beneficial outcome (NNTB) for dichotomous data, and mean difference (MD) for continuous data, with 95% confidence intervals (CIs).

    MAIN RESULTS: Thirteen studies were eligible for inclusion, but only 12 studies contributed data, with a total of 3446 CVCs assessed. The total number of participants enrolled was unclear as some studies did not provide such information. The participants were mainly adults admitted to intensive care units, haematology oncology units or general wards. Most studies assessed skin antisepsis prior to insertion and regularly thereafter during the in-dwelling period of the CVC, ranging from every 24 h to every 72 h. The methodological quality of the included studies was mixed due to wide variation in their risk of bias. Most trials did not adequately blind the participants or personnel, and four of the 12 studies had a high risk of bias for incomplete outcome data.Three studies compared different antisepsis regimens with no antisepsis. There was no clear evidence of a difference in all outcomes examined, including catheter-related BSI, septicaemia, catheter colonisation and number of patients who required systemic antibiotics for any of the three comparisons involving three different antisepsis regimens (aqueous povidone-iodine, aqueous chlorhexidine and alcohol compared with no skin antisepsis). However, there were great uncertainties in all estimates due to underpowered analyses and the overall very low quality of evidence presented.There were multiple head-to-head comparisons between different skin antiseptic agents, with different combinations of active substance and base solutions. The most frequent comparison was chlorhexidine solution versus povidone-iodine solution (any base). There was very low quality evidence (downgraded for risk of bias and imprecision) that chlorhexidine may reduce catheter-related BSI compared with povidone-iodine (RR of 0.64, 95% CI 0.41 to 0.99; ARR 2.30%, 95% CI 0.06 to 3.70%). This evidence came from four studies involving 1436 catheters. None of the individual subgroup comparisons of aqueous chlorhexidine versus aqueous povidone-iodine, alcoholic chlorhexidine versus aqueous povidone-iodine and alcoholic chlorhexidine versus alcoholic povidone-iodine showed clear differences for catheter-related BSI or mortality (and were generally underpowered). Mortality was only reported in a single study.There was very low quality evidence that skin antisepsis with chlorhexidine may also reduce catheter colonisation relative to povidone-iodine (RR of 0.68, 95% CI 0.56 to 0.84; ARR 8%, 95% CI 3% to 12%; ; five studies, 1533 catheters, downgraded for risk of bias, indirectness and inconsistency).Evaluations of other skin antiseptic agents were generally in single, small studies, many of which did not report the primary outcome of catheter-related BSI. Trials also poorly reported other outcomes, such as skin infections and adverse events.

    AUTHORS' CONCLUSIONS: It is not clear whether cleaning the skin around CVC insertion sites with antiseptic reduces catheter related blood stream infection compared with no skin cleansing. Skin cleansing with chlorhexidine solution may reduce rates of CRBSI and catheter colonisation compared with cleaning with povidone iodine. These results are based on very low quality evidence, which means the true effects may be very different. Moreover these results may be influenced by the nature of the antiseptic solution (i.e. aqueous or alcohol-based). Further RCTs are needed to assess the effectiveness and safety of different skin antisepsis regimens in CVC care; these should measure and report critical clinical outcomes such as sepsis, catheter-related BSI and mortality.

  3. Muehlenbein MP, Pacheco MA, Taylor JE, Prall SP, Ambu L, Nathan S, et al.
    Mol Biol Evol, 2015 Feb;32(2):422-39.
    PMID: 25389206 DOI: 10.1093/molbev/msu310
    Although parasitic organisms are found worldwide, the relative importance of host specificity and geographic isolation for parasite speciation has been explored in only a few systems. Here, we study Plasmodium parasites known to infect Asian nonhuman primates, a monophyletic group that includes the lineage leading to the human parasite Plasmodium vivax and several species used as laboratory models in malaria research. We analyze the available data together with new samples from three sympatric primate species from Borneo: The Bornean orangutan and the long-tailed and the pig-tailed macaques. We find several species of malaria parasites, including three putatively new species in this biodiversity hotspot. Among those newly discovered lineages, we report two sympatric parasites in orangutans. We find no differences in the sets of malaria species infecting each macaque species indicating that these species show no host specificity. Finally, phylogenetic analysis of these data suggests that the malaria parasites infecting Southeast Asian macaques and their relatives are speciating three to four times more rapidly than those with other mammalian hosts such as lemurs and African apes. We estimate that these events took place in approximately a 3-4-Ma period. Based on the genetic and phenotypic diversity of the macaque malarias, we hypothesize that the diversification of this group of parasites has been facilitated by the diversity, geographic distributions, and demographic histories of their primate hosts.
Related Terms
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links