A HPLC method was validated for quantification of (+)-calanolide A (1), a novel anti-HIV agent, in rat, dog and human plasma. The synthetic intermediate (+/-)-12-oxocalanolide A (2) was found to be a suitable internal standard. Compounds were extracted from plasma using a solid-phase C(18) cartridge and quantified over the assay range of 12.5 to 800 ng/ml. The method was utilized to determine (+)-calanolide A pharmacokinetics in rats, dogs and humans. This is the first report of a validated HPLC assay for determination of (+)-calanolide A concentrations in rat and dog plasma as well as human plasma obtained from clinical trials. There was no evidence of in vivo epimerization of (+)-calanolide A to its inactive epimer (+)-calanolide B (3).