Displaying all 2 publications

Abstract:
Sort:
  1. Mansor AA, Abdullah S, Ahmad AN, Ahmed AN, Zulkifli MFR, Jusoh SM, et al.
    Dialogues Health, 2024 Jun;4:100178.
    PMID: 38665133 DOI: 10.1016/j.dialog.2024.100178
    Sick Building Syndrome (SBS) is an illness among workers linked to time spent in a building. This study aimed to investigate the Indoor Air Quality (IAQ) and symptoms of Sick Building Syndrome (SBS) among administrative office workers. The IAQ parameters consist of ventilation performance indicators, and physical and chemical parameters were measured using specified instruments for three days during weekdays. The SBS symptoms were assessed by a questionnaire adopted from the Industry Code of Practice of Indoor Air Quality (ICOP-IAQ) 2010 among 19 employees from the office in East Coast Malaysia. Relationship between past symptoms and present symptoms which are draught (past symptoms) with feeling heavy headed (present symptoms) (r = 0.559, p 
  2. Haque J, Zulkifli MFR, Ismail N, Quraishi MA, Mohd Ghazali MS, Berdimurodov E, et al.
    ACS Omega, 2023 Jul 18;8(28):24797-24812.
    PMID: 37483193 DOI: 10.1021/acsomega.3c00366
    Three novel natural amino acid-derived sodium L-2-(1-imidazolyl) alkanoic acids (IZSs), namely, sodium 2-(1H-imidazol-1-yl)-4-methylpentanoate (IZS-L), sodium 2-(1H-imidazol-1-yl)-3-phenylpropanoate (IZS-P), and sodium 2-(1H-imidazol-1-yl)-4-(methylthio)butanoate (IZS-M), were investigated as corrosion inhibitors. The IZSs were synthesized following the green chemistry principles, and their structure was characterized using FTIR and NMR techniques. The corrosion study results reveal that a moderate concentration of IZSs (having low solution conductivity) showed potential corrosion inhibition for mild steel in artificial seawater. At longer immersion, IZS-P forms a uniform protective film and exhibits the potential inhibition efficiency of 82.46% at 8.4 mmol L-1. Tafel polarization results reveal that IZS-P and IZS-M act as mixed types with an anodic predominantly corrosion inhibitor. The electrochemical impedance spectroscopy results signify that IZSs inhibit mild steel corrosion through the formation of an inhibitor film on the metal surface, which was further confirmed by the FTIR, SEM, EDX, and XPS studies. DFT result shows that in IZS-P, the benzylic group (-CH2-Ph) has greater electron distribution compared to isobutyl (-CH2CH(CH3)2) in IZS-L and methythioethyl group (-CH2CH2SCH3) which supported the corrosion inhibition performance at longer immersion [IZS-P (82.46%) > IZS-M (67.19%) > IZS-L (24.77%)].
Related Terms
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links