Displaying all 2 publications

Abstract:
Sort:
  1. Djer MM, Latiff HA, Alwi M, Samion H, Kandavello G
    Heart Lung Circ, 2006 Feb;15(1):12-7.
    PMID: 16473785
    From November 1997 to June 2002, percutaneous transcatheter closure of muscular ventricular septal defects was attempted in seven patients. Four patients had single and three had multiple defects. Surgical closure was performed in two patients in an attempt to close a perimembranous defect, leaving behind a large apical muscular defect, which was successfully closed using a device in one patient, whilst the second patient succumbed to septicemia/endocarditis 3 weeks after failure of device implantation. One patient had previous pulmonary artery banding and in another intraoperative placement of two Clamshell devices followed by additional transcatheter closure using Gianturco coils in two different sessions was performed.
    Matched MeSH terms: Cardiac Surgical Procedures/instrumentation*
  2. Abdelbasit MA, Alwi M, Kandavello G, Che Mood M, Samion H, Hijazi ZM
    Catheter Cardiovasc Interv, 2015 Jul;86(1):94-9.
    PMID: 25675888 DOI: 10.1002/ccd.25878
    OBJECTIVES: To evaluate the feasibility, safety, and efficacy of the Occlutech® PDA occluder for closure of patent ductus arteriosus (PDA).

    BACKGROUND: The Occlutech® PDA occluder is novel, self-shaping Nitinol wire device with PET (polyethylene terephthalate) patches integrated into the shank of the device to assure a better obturation of the ductus. The Occlutech® PDA occluder has undergone two design modifications.

    METHODS: A prospective, non-randomized pilot study was started in November 2011. Thirty-three patients were included until April 2013. Patients weighing <6 kg or those with associated cardiac anomalies that required surgery were excluded. All patients were followed up by transthoracic echocardiography at 24 hr, 30 days, 90 days, 180 days, and 360 days after implantation. Residual shunt, left pulmonary artery (LPA) and descending aortic velocities were among the parameters assessed. All occluders were delivered via 6-8 F long sheaths and PDA closures were performed following standard techniques.

    RESULTS: Thirty three patients (20 female/13 male), with a median age of 2 years (6 month to 38 years), and median weight of 9.3 kg (6-69.2 kg) were included. The narrowest median PDA diameter was 3mm (1.8-5.8 mm). All the 33 patients were closed successfully using Occlutech ductal occluder, 16 patients (48.4%) had immediate and complete closure on angiography. Within 24 hr, color Doppler revealed complete closure in 27patients (81.8%), 32patients (97%) at 30 days, and in 100% of patients at 90 days. All patients with a large PDA had immediate residual shunt which was closed at the 90-day follow-up. There was no device embolization, hemolysis, or obstruction to the LPA or descending aorta.

    CONCLUSION: The new Occlutech® PDA is safe and effective. In patients with a large PDA complete closure tended to take longer time.

    Matched MeSH terms: Cardiac Surgical Procedures/instrumentation*