To determine the values for the anterior best-fit sphere (BFS) and posterior BFS in an Asian population using the Orbscan II (Bausch & Lomb) slit-scanning Placido disk corneal topographer.
To report observations of horizontal corneal diameter (HCD) and central corneal thickness (CCT) changes in premature infants with stable optic disc cupping and intraocular pressures (IOPs). The HCD and CCT at term serve as a baseline for premature infants.Sixty-three premature infants were enrolled in a prospective case series. HCD, CCT, and IOP were measured. RetCam images of the optic discs were used to evaluate the cup-disc ratio (CDR) and read by an independent masked observer. Data were collected at between preterm (32-36 weeks) and again at term (37-41 weeks) postconceptual age. Left eye measurements were used for statistical analysis. Left eye findings were combined to construct predictive models for HCD and CCT.The mean HCD was 9.1 mm (standard deviation [SD] = 0.7 mm) at preterm and 10.0 mm (SD = 0.52 mm) at term. The mean CCT preterm was 618.8 (SD = 72.9) μm and at term 563.9 (SD = 50.7) μm, respectively. The average preterm CDR was 0.31 and at maturity was 0.33. Average IOP of preterm and term was 13.1 and 14.11 mm Hg, respectively. There was significant linear correlation between HCD with the postmenstrual age (r = 0.40, P Corneal diameter correlated with gestational age at birth and head circumference.
To evaluate corneal thickness and volume in subclinical and clinical keratoconus in Asian population with the aim of discriminating between normal and ectatic cornea. Eyes were placed into one of the following three groups: normal, subclinical, and mild-moderate keratoconus. Pentacam Scheimpflug imaging (Oculus Inc., Wetzlar, Germany) was performed for each participant to record thinnest corneal thickness, central corneal thickness, corneal volume (CV), peripheral corneal thickness (PCT) and percentage thickness increase (PTI) at 2, 4, 6, and 8 mm. The data were exported to SPSS for statistical analysis. Subjects comprised 52 normal, 15 subclinical keratoconus, and 32 mild-moderate clinical keratoconus eyes. Our results indicated that corneal thickness (CT) distribution, PTI, and CV in normal eyes were significantly different compared with subclinical and clinical keratoconus (P < .05). Overall, subclinical group exhibited lower CT distribution and volume, and higher PTI in comparison with normal eyes. However, they showed higher CT distribution and volume, and lower PTI compared with keratoconus group. In addition, there was a smaller change in PCT and PTI from the thinnest point of the cornea to the periphery. The results of the present study indicate that CT parameters and CV were significantly different in normal versus subclinical group and in normal versus keratoconus group. These findings could help clinicians to better discriminate between normal and ectatic cornea.