Displaying all 5 publications

Abstract:
Sort:
  1. Azmi MI, Nair AK, Hashim SA
    Innovations (Phila), 2024;19(2):175-183.
    PMID: 38577864 DOI: 10.1177/15569845241238999
    OBJECTIVE: We evaluated the effectiveness of a consistent and structured self-practice coronary anastomosis program using a homemade low-fidelity beating-heart simulator.

    METHODS: An intermediary trainee was subjected to an 8-week structured self-practice program. The program was divided into 2 parts of nonbeating and beating practices with a minimum number of timed anastomoses. Each part was followed by an assessment using an objective skills assessment tool score. The beating-heart simulator was built using motorized toy blocks connected wirelessly to a smartphone application. This was coded to enable rate selection. A junior consultant was compared to the subject at the end of the program. Both were tasked to perform 1 coronary anastomosis for both off-pump coronary artery bypass (OPCAB) and minimally invasive CAB (MICS) setup. The primary outcomes were anastomotic time and score compared with the junior consultant. Secondary outcomes were progression of anastomotic time and score throughout the program.

    RESULTS: Overall performance of the studied subject approached the performance of the junior consultant in terms of time (OPCAB, 489 vs 605 s; MICS, 712 vs 652 s) and scores (OPCAB, 21 vs 20.7; MICS, 19 vs 20.6). There were inverse correlations between anastomosis time and number of practices for both nonbeating and beating anastomoses. Overall improvement was observed in terms of assessment scoring by 26.6%.

    CONCLUSIONS: A structured self-practice program using an affordable and accessible simulator was able to help trainees overcome the MICS anastomosis learning curve quicker when introduced earlier. This may encourage earlier adoption of MICS among surgeons.

    Matched MeSH terms: Coronary Artery Bypass, Off-Pump/education; Coronary Artery Bypass, Off-Pump/methods
  2. Abdullah F, Mazalan SL
    Heart Surg Forum, 2004;7(3):E186-8.
    PMID: 15262598
    We present an interesting but high-risk case of an obese male patient aged 56 years with dextrocardia and a left diaphragmatic hernia. Anterior myocardial infarction was diagnosed in 1994, and the patient later presented with a history of unstable angina. The diagnosis for this chronic smoker was triple-vessel disease, impaired left ventricular function, chronic renal failure, chronic bronchitis, impaired lung function, pulmonary hypertension, hypertension, diabetes, and chronic active gastritis (EuroSCORE of 10). The patient underwent successful off-pump coronary artery bypass grafting with 3 saphenous vein grafts to the left anterior descending, obtuse marginal, and right posterior descending arteries. He was discharged home 8 days later.
    Matched MeSH terms: Coronary Artery Bypass, Off-Pump*
  3. Maeba S, Nemoto S, Hamdan L, Okada T, Azhari M
    Kyobu Geka, 2006 Nov;59(12):1075-8.
    PMID: 17094543
    From April 2002 to March 2005, 18 patients having undergone bidirectional Glenn shunt (BDG) without cardiopulmonary bypass (CPB) [off-pump BDG] were retrospectively reviewed. During BDG anastomosis, a temporary bypass was established between superior vena cava (15) or innominate vein (3) and main pulmonary artery (16) or right atrium (2). Hemodynamics and oxygenation were maintained well throughout the temporary bypass time. There was no emergent use of CPB. Mean transpulmonary pressure gradient immediately after and 24 hours after the BDG were 6.7 and 5.6 mmHg, respectively. Echocardiography showed mild flow turbulence at the anastomosis in 1 case. This simple and inexpensive technique provided good surgical view with stable hemodynamics enabling satisfactory BDG in selected cases. Furthermore, it could avoid adverse effects of CPB such as lung injury and possible blood transfusion. This experience would encourage off-pump BDG combined with more challenging procedures.
    Matched MeSH terms: Coronary Artery Bypass, Off-Pump*
  4. Rahman MR, Min JO, Dimon MZ
    Heart Surg Forum, 2010 Aug;13(4):E273-4.
    PMID: 20719738 DOI: 10.1532/HSF98.20101001
    Delayed ascending aortic dissection following coronary artery bypass surgery is a rare but lethal complication. We present the case of a 54-year-old man with a delayed acute Stanford A aortic dissection following an off-pump coronary artery bypass surgery in preexisting chronic type B disease. Such a case of an iatrogenic acute aortic dissection poses a significant challenge and dilemma in choosing the best technique for coronary revascularization in this group of patients. The pathophysiology and technical options are discussed.
    Matched MeSH terms: Coronary Artery Bypass, Off-Pump/adverse effects*; Coronary Artery Bypass, Off-Pump/methods
  5. Ooi JS, Abdul Rahman MR, Shah SA, Dimon MZ
    Asian Cardiovasc Thorac Ann, 2008 Dec;16(6):468-72.
    PMID: 18984756
    A prospective study was carried out to compare the outcomes of patients with preexisting non-dialysis-dependent renal dysfunction who underwent coronary artery bypass grafting with or without cardiopulmonary bypass. Elective off-pump coronary artery bypass was performed in 29 patients with renal dysfunction. Their results were compared with those of a similar group of 35 patients who underwent the conventional on-pump coronary artery grafting. There was a significant deterioration in creatinine clearance in the on-pump group on days 1, 2, and 4 after surgery, while creatinine clearance in the off-pump group remained close to the baseline level. Both groups had improved to the preoperative creatinine clearance values on follow-up at 4 weeks. It was concluded that off-pump surgery provided better renal protection than the conventional on-pump technique in patients with preexisting non-dialysis-dependent renal dysfunction.
    Matched MeSH terms: Coronary Artery Bypass, Off-Pump/adverse effects*
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links