Displaying all 2 publications

Abstract:
Sort:
  1. Samuel ED, Griffiths GS, Petrie A
    J Clin Periodontol, 1997 May;24(5):340-5.
    PMID: 9178114
    The aim of this study was to investigate the accuracy and reproducibility of experienced and inexperienced examiners using 3 automated periodontal probes (Florida Pocket Probe, Florida Disk Probe, Peri Probe) in comparison with 3 conventional periodontal probes (Marquis, Williams and EN-15 probes). Test blocks of aluminium had 30 holes of diameter 1.10 mm and depths ranging from 2.75 to 10.0 mm. machined with a tolerance of +/- 0.01 mm. 8 experienced examiners and 8 inexperienced examiners were selected to perform duplicate measurements on the blocks over 6 visits using each of the 6 probes. 1 automated and 1 conventional probe were used at each examination. The % accuracy and reproducibility for each of the duplicate measurements was calculated and analysed using Friedman 2-way analysis of variance and the Wilcoxon matched pairs test. On average, all probes showed high reproducibility, with the Florida Disk Probe, the Florida Pocket Probe and the Williams probe ranked best and the other 3 probes were less reproducible. On average, all probes showed a high degree of accuracy, automated probes were ranked best and were significantly better than conventional probes. Experience had little effect on reproducibility, with only the Peri Probe showing significant differences at the 5% level between the groups. Experience appeared to be more important for accuracy, as experienced examiners were more accurate than inexperienced examiners, with significant differences at the 5% level for the EN-15, Florida Disk Probe and Peri Probe. However, inexperienced examiners were significantly more accurate using the Williams probe. This in vitro study has shown that automated probes offer increased accuracy over conventional probes and the Florida Pocket and disk probes compare well with conventional probes for reproducibility.
    Matched MeSH terms: Diagnosis, Oral/instrumentation*
  2. Rahman HA, Che Ani AI, Harun SW, Yasin M, Apsari R, Ahmad H
    J Biomed Opt, 2012 Jul;17(7):071308.
    PMID: 22894469 DOI: 10.1117/1.JBO.17.7.071308
    The purpose of this study is to investigate the potential of intensity modulated fiber optic displacement sensor scanning system for the imaging of dental cavity. Here, we discuss our preliminary results in the imaging of cavities on various teeth surfaces, as well as measurement of the diameter of the cavities which are represented by drilled holes on the teeth surfaces. Based on the analysis of displacement measurement, the sensitivities and linear range for the molar, canine, hybrid composite resin, and acrylic surfaces are obtained at 0.09667 mV/mm and 0.45 mm; 0.775 mV/mm and 0.4 mm; 0.5109 mV/mm and 0.5 mm; and 0.25 mV/mm and 0.5 mm, respectively, with a good linearity of more than 99%. The results also show a clear distinction between the cavity and surrounding tooth region. The stability, simplicity of design, and low cost of fabrication make it suitable for restorative dentistry.
    Matched MeSH terms: Diagnosis, Oral/instrumentation*
Related Terms
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links