Displaying all 4 publications

Abstract:
Sort:
  1. Baharuddin MY, Salleh ShH, Hamedi M, Zulkifly AH, Lee MH, Mohd Noor A, et al.
    Biomed Res Int, 2014;2014:478248.
    PMID: 24800230 DOI: 10.1155/2014/478248
    Stress shielding and micromotion are two major issues which determine the success of newly designed cementless femoral stems. The correlation of experimental validation with finite element analysis (FEA) is commonly used to evaluate the stress distribution and fixation stability of the stem within the femoral canal. This paper focused on the applications of feature extraction and pattern recognition using support vector machine (SVM) to determine the primary stability of the implant. We measured strain with triaxial rosette at the metaphyseal region and micromotion with linear variable direct transducer proximally and distally using composite femora. The root mean squares technique is used to feed the classifier which provides maximum likelihood estimation of amplitude, and radial basis function is used as the kernel parameter which mapped the datasets into separable hyperplanes. The results showed 100% pattern recognition accuracy using SVM for both strain and micromotion. This indicates that DSP could be applied in determining the femoral stem primary stability with high pattern recognition accuracy in biomechanical testing.
    Matched MeSH terms: Hip Joint/physiopathology*
  2. Shiek Ahmad B, Petty SJ, Gorelik A, O'Brien TJ, Hill KD, Christie JJ, et al.
    Osteoporos Int, 2017 Sep;28(9):2591-2600.
    PMID: 28589417 DOI: 10.1007/s00198-017-4098-9
    Changes in areal bone mineral density (aBMD) and other predictors of bone loss were evaluated in 48 same-sex twin/age-matched sibling pairs discordant for antiepileptic drug (AED) use. AED users had reduced BMD at the hip regions. Prolonged AED users had greater aBMD loss, predicting a higher risk of bone fragility.

    INTRODUCTION: To investigate the longitudinal associations of bone mineral measures with antiepileptic drug (AED) use, including enzyme-inducing (EIAED) and non-enzyme-inducing (NEIAED) types, and other predictors of bone loss in a study of 48 same-sex twin/age-matched sibling pairs (40 female, 8 male) discordant for AED use.

    METHODS: Using dual-energy X-ray absorptiometry (DXA), areal bone mineral density (aBMD) and content (BMC) at the hip regions, forearm, lumbar spine, and whole body were measured twice, at least 2 years apart. The mean within-pair difference (MWPD), MWPD%, and mean annual rate of aBMD change were adjusted for age, weight, and height. Predictors of bone loss were evaluated.

    RESULTS: AED users, compared to non-users, at baseline and follow-up, respectively, had reduced aBMD at the total hip (MWPD% 3.8, 4.4%), femoral neck (4.7, 4.5%), and trochanter regions (4.1, 4.6%) (p  0.05) regions did not differ within pairs. Nevertheless, EIAED users had greater aBMD loss than non-users (n = 20 pairs) at the total hip (1.7 vs. 0.3%, p = 0.013) and whole body regions (0.7% loss vs. 0.1% BMD gain, p = 0.019), which was not found in NEIAED-discordant pairs (n = 16). AED use >20 years predicted higher aBMD loss at the forearm (p = 0.028), whole body (p = 0.010), and whole body BMC (p = 0.031).

    CONCLUSIONS: AED users had reduced aBMD at the hip regions. Prolonged users and EIAED users had greater aBMD loss, predicting a higher risk of bone fragility. Further prospective studies of AED effects on bone microarchitecture are needed.

    Matched MeSH terms: Hip Joint/physiopathology
  3. Ling XF, Peng X, Samman N
    J Oral Maxillofac Surg, 2013 Sep;71(9):1604-12.
    PMID: 23810616 DOI: 10.1016/j.joms.2013.03.006
    This study evaluated and compared the long-term donor-site morbidity of the free fibula flap with the deep circumflex iliac artery (DCIA) flap in maxillofacial reconstruction.
    Matched MeSH terms: Hip Joint/physiopathology
Related Terms
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links