METHODS: Colonic EMRs performed for polypoid and nonpolypoid lesions at a tertiary institution were prospectively collected and analyzed for efficacy, and short and long-term complications.
RESULTS: 224 colonic neoplasms (143 flat, 65 sessile and 16 subpedunculated) were excised by the standard inject-and-cut method, with standard accessories. The median size of all lesions was 10 mm (range 2-50 mm) and 110 (49.2%) lesions were located in the proximal colon. Histological completeness of resection was achieved in 87% of cases. Of the lesions 77.2% were dysplastic, with 5 cases of carcinoma in situ and 18 severely dysplastic adenomas. Complications included bleeding in five cases (2.2 %) and a single case of perforation (0.4%). All complications were managed endoscopically. Median follow up at 24 +/- 16 months (range 12-84 months) revealed a 7.2% local recurrence rate, all of which were subsequently eradicated by repeat EMR.
CONCLUSIONS: Standard inject-and-cut colonic EMR is practical and effective in the eradication of superficial colonic neoplasia.