METHODS: We did a sequential annual cross-sectional study of 2164 children aged 8-9 years attending primary schools between 2009-10 and 2013-14 in central London, UK, following the introduction of London's LEZ in February, 2008. We examined the association between modelled pollutant exposures of nitrogen oxides (including nitrogen dioxide [NO2]) and particulate matter with a diameter of less than 2·5 μm (PM2·5) and less than 10 μm (PM10) and lung function: postbronchodilator forced expiratory volume in 1 s (FEV1, primary outcome), forced vital capacity (FVC), and respiratory or allergic symptoms. We assigned annual exposures by each child's home and school address, as well as spatially resolved estimates for the 3 h (0600-0900 h), 24 h, and 7 days before each child's assessment, to isolate long-term from short-term effects.
FINDINGS: The percentage of children living at addresses exceeding the EU limit value for annual NO2 (40 μg/m3) fell from 99% (444/450) in 2009 to 34% (150/441) in 2013. Over this period, we identified a reduction in NO2 at both roadside (median -1·35 μg/m3 per year; 95% CI -2·09 to -0·61; p=0·0004) and background locations (-0·97; -1·56 to -0·38; p=0·0013), but not for PM10. The effect on PM2·5 was equivocal. We found no association between postbronchodilator FEV1 and annual residential pollutant attributions. By contrast, FVC was inversely correlated with annual NO2 (-0·0023 L/μg per m3; -0·0044 to -0·0002; p=0·033) and PM10 (-0·0090 L/μg per m3; -0·0175 to -0·0005; p=0·038).
INTERPRETATION: Within London's LEZ, a smaller lung volume in children was associated with higher annual air pollutant exposures. We found no evidence of a reduction in the proportion of children with small lungs over this period, despite small improvements in air quality in highly polluted urban areas during the implementation of London's LEZ. Interventions that deliver larger reductions in emissions might yield improvements in children's health.
FUNDING: National Institute for Health Research Biomedical Research Centre at Guy's and St Thomas' National Health Service (NHS) Foundation Trust and King's College London, NHS Hackney, Lee Him donation, and Felicity Wilde Charitable Trust.
OBJECTIVE: To assess and compare the RQoL of the occupationally exposed (firefighters and traffic police) and the occupationally unexposed populations in Penang, Malaysia.
METHODS: We recruited male traffic police and firefighters from 5 districts of Penang by convenient sampling during June to September 2018. Participants completed the SGRQ. Scores (symptoms, activity, impacts, total) were derived using a scoring calculator. Higher scores indicate poorer RQoL. Univariate and multivariate linear regression models were fitted to explore the relationship of the independent predictive factors with participants' RQoL.
RESULTS: We recruited 706 participants---211 firefighters, 198 traffic police, and 297 from general population. Smokers had significantly higher scores than non-smokers in all SGRQ domains. Regardless of smoking status, the "occupationally exposed group" had higher symptoms score than the "occupationally unexposed group," who had higher activity and impact scores. Smoking status, comorbidity status and monthly income were significant independent predictors of SGRQ total score.
CONCLUSION: In comparison with the general population, firefighters and traffic police reported poorer RQoL; smoking further deteriorated their respiratory health. There is a need to strengthen preventive health measures against occupational disease and smoking cessation among firefighters and traffic police.
METHODS: A cross-sectional study was conducted in a steel factory in Terengganu, Malaysia to assess the metal dust exposure and its relationship to lung function values among 184 workers. Metal dust concentrations values (Co, Cr, and Ni) for each worker were collected using air personal sampling. Lung function values (FEV1, FVC, and %FEV1/FVC) were determined using spirometer.
RESULTS: Exposure to cobalt and chromium were 1-3 times higher than permissible exposure limit (PEL) while nickel was not exceeding the PEL. Cumulative of chromium was the predictor to all lung function values (FEV1, FVC, and %FEV1/FVC). Frequency of using mask was positively associated with FVC (Adj b = 0.263, P = 0.011) while past respiratory illnesses were negatively associated with %FEV1/FVC (Adj b = -1.452, P = 0.026). Only few workers (36.4%) were found to wear their masks all times during the working hours.
CONCLUSIONS: There was an exposure-response relationship of cumulative metal dust exposure with the deterioration of lung function values. Improvement of control measures as well as proper and efficient use or personal protection equipment while at work could help to protect the respiratory health of workers.