Displaying all 3 publications

Abstract:
Sort:
  1. Tsan SEH, Lim SM, Abidin MFZ, Ganesh S, Wang CY
    Anesth Analg, 2020 07;131(1):210-219.
    PMID: 31348051 DOI: 10.1213/ANE.0000000000004349
    BACKGROUND: Approximately half of all difficult tracheal intubations (DTIs) are unanticipated; hence, proper positioning during intubation is critical to increase the likelihood of success. The bed-up-head-elevated (BUHE) intubation position has been shown to improve laryngeal view, reduce airway complications, and prolong safe apneic time during intubation. In this study, we sought to determine whether the BUHE intubation position is noninferior to Glidescope (GLSC)-assisted intubation with regard to laryngeal exposure.

    METHODS: A total of 138 American Society of Anesthesiologists (ASA) I to III patients were randomly assigned into 2 groups and underwent baseline laryngoscopy in the sniffing position. Group BUHE patients (n = 69) were then intubated in the BUHE position, while group GLSC patients (n = 69) were intubated using GLSC laryngoscopy. Laryngeal exposure was measured using Percentage of Glottic Opening (POGO) score and Cormack-Lehane (CL) grading, and noninferiority will be declared if the difference in mean POGO scores between both groups do not exceed -15% at the lower limit of a 98% confidence interval (CI). Secondary outcomes measured included time required for intubation (TRI), number of intubation attempts, use of airway adjuncts, effort during laryngoscopy, and complications during intubation.

    RESULTS: Mean POGO score in group BUHE was 80.14% ± 22.03%, while in group GLSC it was 86.45% ± 18.83%, with a mean difference of -6.3% (98% CI, -13.2% to 0.6%). In both groups, there was a significant improvement in mean POGO scores when compared to baseline laryngoscopy in the sniffing position (group BUHE, 25.8% ± 4.7%; group GLSC, 30.7% ± 6.8%) (P < .0001). The mean TRI was 36.23 ± 14.41 seconds in group BUHE, while group GLSC had a mean TRI of 44.33 ± 11.53 seconds (P < .0001). In patients with baseline CL 3 grading, there was no significant difference between mean POGO scores in both groups (group BUHE, 49.2% ± 19.6% versus group GLSC, 70.5% ± 29.7%; P = .054).

    CONCLUSIONS: In the general population, BUHE intubation position provides a noninferior laryngeal view to GLSC intubation. The laryngeal views obtained in both approaches were superior to the laryngeal view obtained in the sniffing position. In view of the many advantages of the BUHE position for intubation, the lack of proven adverse effects, the simplicity, and the cost-effectiveness, we propose that clinicians should consider the BUHE position as the standard intubation position for the general population.

    Matched MeSH terms: Supine Position/physiology*
  2. Goh CH, Ng SC, Kamaruzzaman SB, Chin AV, Tan MP
    Medicine (Baltimore), 2017 Oct;96(42):e8193.
    PMID: 29049203 DOI: 10.1097/MD.0000000000008193
    The aim of this study was to determine the relationship between falls and beat-to-beat blood pressure (BP) variability.Continuous noninvasive BP measurement is as accurate as invasive techniques. We evaluated beat-to-beat supine and standing BP variability (BPV) using time and frequency domain analysis from noninvasive continuous BP recordings.A total of 1218 older adults were selected. Continuous BP recordings obtained were analyzed to determine standard deviation (SD) and root mean square of real variability (RMSRV) for time domain BPV and fast-Fourier transform low frequency (LF), high frequency (HF), total power spectral density (PSD), and LF:HF ratio for frequency domain BPV.Comparisons were performed between 256 (21%) individuals with at least 1 fall in the past 12 months and nonfallers. Fallers were significantly older (P = .007), more likely to be female (P = .006), and required a longer time to complete the Timed-Up and Go test (TUG) and frailty walk test (P ≤ .001). Standing systolic BPV (SBPV) was significantly lower in fallers compared to nonfallers (SBPV-SD, P = .016; SBPV-RMSRV, P = .033; SBPV-LF, P = .003; SBPV-total PSD, P = .012). Nonfallers had significantly higher supine to standing ratio (SSR) for SBPV-SD, SBPV-RMSRV, and SBPV-total PSD (P = .017, P = .013, and P = .009). In multivariate analyses, standing BPV remained significantly lower in fallers compared to nonfallers after adjustment for age, sex, diabetes, frailty walk, and supine systolic BP. The reduction in frequency-domain SSR among fallers was attenuated by supine systolic BP, TUG, and frailty walk.In conclusion, reduced beat-to-beat BPV while standing is independently associated with increased risk of falls. Changes between supine and standing BPV are confounded by supine BP and walking speed.
    Matched MeSH terms: Supine Position/physiology
  3. Fang SY, Wan Abdul Halim WH, Mat Baki M, Din NM
    Graefes Arch Clin Exp Ophthalmol, 2018 Apr;256(4):783-790.
    PMID: 29492688 DOI: 10.1007/s00417-018-3919-7
    PURPOSE: Obstructive sleep apnea syndrome (OSAS) patients are at risk of glaucoma but the risk increases if they have higher intraocular pressure (IOP) while sleeping. We aim to evaluate the postural effect of upright and prolong supine positions on IOP in these patients.

    METHODS: This is a cross-sectional study involving 27 patients with symptoms of OSAS seen at a tertiary institutional center and 25 normal controls performed between June 2015 and June 2016. All patients and controls underwent a polysomnography (PSG) test and were diagnosed with OSAS based on the apnea-hypopnea index (AHI). Patients are those with OSAS symptoms and had AHI > 5, whereas controls are staffs from the ophthalmology clinic without clinical criteria for OSAS and had PSG result of AHI

    Matched MeSH terms: Supine Position/physiology*
Related Terms
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links