RESULTS: Five factors with eigenvalue > 1 were identified. Pattern matrix analysis showed that all items were loaded into the factors with factor loading > 0.4. One item was subsequently removed as Cronbach's alpha > 0.9 which indicates redundancy. Confirmatory factor analysis demonstrated acceptable factor loadings except for one item which was subsequently removed. Internal consistency and discriminant validity was deemed acceptable with no significant cross-loading.
OBJECTIVES: This study aimed to compare the outcomes of patients with moderate to severe TBI treated with Sterofundin (SF) versus NS.
DESIGN, SETTINGS AND PARTICIPANTS: A double-blinded randomised controlled trial of patients aged 18 to 65 years with TBI was conducted at the University Malaya Medical Centre from February 2017 to November 2019.
INTERVENTION OR EXPOSURE: Patients were randomly assigned to receive either NS or SF. The study fluids were administered for 72 h as continuous infusions or boluses. Participants, investigators, and staff were blinded to the fluid type.
OUTCOMES MEASURE AND ANALYSIS: The primary outcome was in-hospital mortality. Relative risk (RR) with 95% confidence interval (CI) was calculated.
MAIN RESULTS: A total of 70 patients were included in the analysis, with 38 in the NS group and 32 in the SF group. The in-hospital mortality rate were 3 (7.9%) in the NS group vs. 4 (12.5%) in the SF group, RR = 1.29 (95% CI, 0.64 to 2.59; p = 0.695). No patients developed AKI and required renal replacement therapy. ICP on day 3 was significantly higher in the SF group (18.60 ± 9.26) compared to 12.77 ± 3.63 in the NS group, (95% CI, -11.46 to 0.20; p = 0.037). There were no significant differences in 3-day biochemical parameters and cerebral perfusion pressure, ventilator-free days, length of ICU stay, or Glasgow Outcome Scale-Extended (GOS-E) score at 6 months.
CONCLUSIONS: In patients with moderate to severe TBI, the use of SF was not associated with reduced in-hospital mortality, development of AKI, or improved 6-month GOS-E when compared to NS.
METHODS: This retrospective study was conducted in emergency departments of two tertiary hospitals from June 1 to August 31, 2021. Consecutive patients aged >18 years admitted for COVID-19-related HRF (World Health Organization criteria: confirmed COVID-19 pneumonia with respiratory rate > 30 breaths/min, severe respiratory distress, or peripheral oxygen saturation < 90% on room air) requiring NRB + NC or HFNC were screened for enrollment. Primary outcome was improvement of partial pressure arterial oxygen (PaO2) at two hours. Secondary outcomes were intubation rate, ventilator-free days, hospital length of stay, and 28-day mortality. Data were analyzed using linear regression with inverse probability of treatment weighting (IPTW) based on propensity score.
RESULTS: Among the 110 patients recruited, 52 (47.3%) were treated with NRB + NC, and 58 (52.7%) with HFNC. There were significant improvements in patients' PaO2, PaO2/FIO2 ratio, and respiratory rate two hours after the initiation of NRB + NC and HFNC. Comparing the two groups, after IPTW adjustment, there were no statistically significant differences in PaO2 improvement (adjusted mean ratio [MR] 2.81; 95% CI -5.82 to 11.43; p = .524), intubation rate (adjusted OR 1.76; 95% CI 0.44 to 6.92; p = .423), ventilator-free days (adjusted MR 0.00; 95% CI -8.84 to 8.85; p = .999), hospital length of stay (adjusted MR 3.04; 95% CI -2.62 to 8.69; p = .293), and 28-day mortality (adjusted OR 0.68; 95% CI 0.15 to 2.98; p = .608).
CONCLUSION: HFNC may be beneficial in COVID-19 HRF. NRB + NC is a viable alternative, especially in resource-limited settings, given similar improvement in oxygenation at two hours, and no significant differences in long-term outcomes. The effectiveness of NRB + NC needs to be investigated by a powered randomized controlled trial.
METHODS: This was a randomised cross-over study conducted between 9 April to 5 May 2020 in the ED of University Malaya Medical Centre. Postgraduate Emergency Medicine trainees performed video laryngoscope-assisted intubation on an airway manikin with and without an aerosol box in a random order. Contamination was simulated by nebulised Glo Germ. Primary outcome was number of contaminated front and back body regions pre-doffing and post-doffing of PPE of the intubator and assistant. Secondary outcomes were intubation time, Cormack-Lehane score, number of intubation attempts and participants' feedback.
RESULTS: Thirty-six trainees completed the study interventions. The number of contaminated front and back body regions pre-doffing of PPE was significantly higher without the aerosol box (all p values<0.001). However, there was no significant difference in the number of contaminations post-doffing of PPE between using and not using the aerosol box, with a median contamination of zero. Intubation time was longer with the aerosol box (42.5 s vs 35.5 s, p<0.001). Cormack-Lehane scores were similar with and without the aerosol box. First-pass intubation success rate was 94.4% and 100% with and without the aerosol box, respectively. More participants reported reduced mobility and visibility when intubating with the aerosol box.
CONCLUSIONS: An aerosol box may significantly reduce exposure to contaminations but with increased intubation time and reduced operator's mobility and visibility. Furthermore, the difference in degree of contamination between using and not using an aerosol box could be offset by proper doffing of PPE.