Displaying publications 1 - 20 of 41 in total

Abstract:
Sort:
  1. Ismail Z, Alwi M, Lim MK, Murtazam HA, Jamaluddin A
    Acta Paediatr Jpn, 1994 Feb;36(1):44-8.
    PMID: 8165907
    Nine children, aged 2.5 months to 16 years, presenting with tachyarrhythmias were treated with intravenous (i.v.) flecainide, a type 1C antiarrhythmic drug. There were four boys and five girls; seven were supraventricular and two ventricular tachycardias and three had structural cardiac abnormalities. The i.v. dose required to terminate the arrhythmias ranged from 1.0 to 2.4 mg/kg (mean 1.55 mg/kg) although a mean of 1.94 mg/kg per dose was required to maintain sustained sinus rhythm after a single i.v. dose. Eight of the patients--six supraventricular and two ventricular tachyarrhythmias, required maintenance oral flecainide. Oral dosages of 6.7-9.5 mg/kg per day (mean of 7.97 mg/kg per day in three divided doses) were required to effectively prevent the tachyarrhythmias. Intravenous and oral flecainide are safe and effective in terminating supraventricular and ventricular tachyarrhythmias. No evidence of proarrhythmia was found in the patients during follow up of between 5 and 9 months. The present limitation of performing radiofrequency ablation on infants and small children justifies the important place of medical therapy for re-entrant supraventricular tachyarrhythmias.
  2. Alwi M
    Ann Pediatr Cardiol, 2008 Jan;1(1):38-45.
    PMID: 20300236 DOI: 10.4103/0974-2069.41054
    Ductal stenting is an attractive alternative to conventional shunt surgery in duct dependent congenital heart disease as it avoids thoracotomy and its related problems. With today's generation of coronary stents which have better profile, flexibility and trackability, ductal stenting may be achieved safely and with considerably less difficulty than previously described.As in Blalock-Taussig (BT) shunt, ductal stenting is indicated mainly in duct-dependent cyanotic lesions chiefly in the neonatal period. Unlike the Patent ductus arteriosus (PDA) as an isolated lesion, the ductus in cyanotic heart disease has a remarkable morphologic variability. The ductus tends to arise more proximally under the aortic arch, giving rise to a vertical ductus or occasionally it may arise from the subclavian artery. It also tends to be long and sometimes very tortuous, rendering stent implantation technically impossible. The ductus in these patients may also insert onto one of the branch pulmonary arteries with some stenosis at the site of insertion. The ductus in Tetralogy of Fallot with pulmonary atresia (TOF-PA) tend to exhibit these morphologic features and to a lesser degree in transposition of great arteries with ventricular septal defect and pulmonary atresia (TGA-VSD-PA) and the more complex forms of univentricular hearts. In the preliminary angiographic evaluation, it is important to delineate these morphologic features as the basis for case selection.Ductal stenting may be done by the retrograde femoral artery route or the antegrade transvenous route depending on the ductus morphology and the underlying cardiac lesion. The detailed techniques and essential hardware are described. Finally, major potential complications of the procedure are described. Acute stent thrombosis is the most serious and potentially catastrophic. Emergent treatment with thrombolytic therapy and mechanical disruption of thrombus are required. With proper case selection, appropriate technique and the right hardware ductal stenting provides reasonable short-medium term palliation in duct-dependent cyanotic heart disease.
  3. Hayashi T, Akhtar S, Alwi M
    Ann Pediatr Cardiol, 2017 6 2;10(2):206-208.
    PMID: 28566833 DOI: 10.4103/0974-2069.205143
    We report our experience with a stent migration after right ventricle outflow tract stenting and converted to patent ductus arteriosus stenting in Tetralogy of Fallot (TOF) with severe infundibular stenosis. Finally, the patient achieved to TOF repair, and the migrated stent was removed without any complication.
  4. Elarabi AI, Leong MC, Alwi M
    Ann Pediatr Cardiol, 2017 6 2;10(2):203-205.
    PMID: 28566832 DOI: 10.4103/0974-2069.205157
    We report an 8-year-old male child with tetralogy of Fallot (TOF), who developed left pulmonary artery (LPA) atresia, following surgical repair of TOF and left pulmonary arterioplasty at the age of 6 years. He underwent successful radiofrequency recanalization and stenting of the LPA. The LPA exhibited satisfactory growth for 3 months, following recanalization and stenting.
  5. Lee J, Sivalingam S, Alwi M
    Ann Pediatr Cardiol, 2017 9 21;10(3):281-283.
    PMID: 28928615 DOI: 10.4103/apc.APC_168_16
    We report a case of Tetralogy of Fallot with severe cyanosis who underwent a successful right ventricular outflow tract stenting. Follow-up echocardiography revealed moderate aortic regurgitation due to the impingement of the stent on the aortic valve. The patient underwent successful surgical correction at which time the stent was removed completely with a resolution of the aortic regurgitation.
  6. Alwi M, Hamid ZA, Zambahari R
    Br Heart J, 1992 Jul;68(1):6-8.
    PMID: 1515294
    Continuous wave Doppler recordings of the turbulent jet through the restrictive orifice of a left atrial partition in a patient with corrected transposition of the great arteries and cor triatriatum showed alternate bands of high intensity diastolic and low intensity systolic signals with preservation of the normal configuration of the diastolic E and A peaks. It is thought that Doppler studies in cor triatriatum will provide useful complementary haemodynamic information in the echocardiographic diagnosis of this anomaly.
  7. Alwi M, Kandavello G, Choo KK, Aziz BA, Samion H, Latiff HA
    Cardiol Young, 2005 Apr;15(2):141-7.
    PMID: 15845156
    Some patients with pulmonary atresia with an intact ventricular septum, mild to moderate right ventricular hypoplasia, and a patent infundibulum remain duct dependent on the flow of blood through the arterial duct despite adequate relief of the obstruction within the right ventricular outflow tract. The objective of our study was to review the risk factors for stenting of the patent arterial duct, or construction of a Blalock-Taussig shunt, in the patients with pulmonary atresia and an intact ventricular septum who remain duct-dependent following radiofrequency valvotomy and dilation of the imperforate pulmonary valve. We reviewed the data from 53 patients seen between November 1995 and December 2001. Of the 47 patients who survived, 6 required stenting of the patent arterial duct, while 4 needed construction of a modified Blalock-Taussig shunt to augment the flow of blood to the lungs at a mean of 7 plus or minus 5.7 days following the initial intervention. The remaining 37 patients required no additional procedures. We compared the findings in these two groups. The mean diameter of the tricuspid valve in the patients requiring early reintervention was 8.5 plus or minus 3.7 millimetres, giving a Z-score of -1.1 plus or minus 1.47, whilst those in the group without early reintervention had values of 10.7 plus or minus 2.2 millimetres, giving a Z-score of -0.58 plus or minus 1.18 (p equal to 0.003). No statistically significant differences were found in right ventricular morphology, McGoon ratio, or residual obstruction across the right ventricular outflow tract after decompression of the right ventricle. The diameter of the tricuspid valve, therefore, appears to be the only factor predicting the need for augmentation of flow of blood to the lungs. As just over one-fifth of our survivors required such augmentation, we hypothesize that stenting of the patent arterial duct may be performed as an integral part of primary transcatheter therapy in patients with pulmonary atresia and intact ventricular septum who have moderate right ventricular hypoplasia and a small tricuspid valve.
  8. Latiff HA, Alwi M, Samion H, Kandhavel G
    Cardiol Young, 2002 May;12(3):224-8.
    PMID: 12365167
    This study reviewed the short-term outcome of transcatheter closure of the defects within the oval fossa using an Amplatzer Septal Occluder. From January 1997 to December 2000, 210 patients with defects within the oval fossa underwent successful transcatheter closure. We reviewed a total of 190 patients with left-to-right shunts, assessing the patients for possible complications and the presence of residual shunts using transthoracic echocardiogram at 24 h, 1 month, 3 months and one year. Their median age was 10 years, with a range from 2 to 64 years, and their median weight was 23.9 kg, with a range from 8.9 to 79 kg. In 5 patients, a patent arterial duct was closed, and in 2 pulmonary balloon valvoplasty performed, at the same sitting. The median size of the Amplatzer device used was 20 mm, with a range from 9 to 36 mm. The median times for the procedure and fluoroscopy were 95 min, with a range from 30 to 210 min, and 18.4 min, with a range from 5 to 144 min, respectively. Mean follow-up was 20.8 +/- 12.4 months. Complete occlusion was obtained in 168 of 190 (88%) patients at 24 h, 128 of 133 (96.2%) at 3 months, and 103 of 104 (99%) at one year. Complications occurred in 4 (2.1%) patients. In one, the device became detached, in the second the device embolized into the right ventricular outflow tract, the lower end of the device straddled in the third, and the final patient had significant bleeding from the site of venupuncture. There were no major complications noted on follow-up. We conclude that transcatheter closure of defects within the oval fossa using the Amplatzer Septal Occluder is safe and effective. Long-term follow-up is required, nonetheless, before it is recommended as a standard procedure.
  9. Latiff HA, Samion H, Kandhavel G, Aziz BA, Alwi M
    Cardiol Young, 2001 Mar;11(2):201-4.
    PMID: 11293739
    BACKGROUND: From January, 1997, as part of an international multicentric trial, we have been closing small-to-moderate atrial septal defects within the oval fossa using the Amplatzer Septal Occluder (ASO, AGA Medical).

    METHODS: All patients with defects within the oval fossa deemed potentially suitable for transcatheter closure were investigated by transesophageal echocardiography with the aim of gaining extra information that might alter the decision to use the device to close the defect. Views were obtained in transverse and longitudinal planes, permitting measurements of the diameter of the defect, and its distance from the atrioventricular valves, coronary sinus, and pulmonary veins. Additionally, we sought to identify multiple defects, and to exclude sinus venosus defects.

    RESULTS: Of 56 patients with left-to-right shunts, 41 (73.2%) were deemed suitable for closure with the Amplatzer Septal Occluder. All underwent the procedure successfully, with no complications. This includes 5 patients with multiple small defects that were sufficiently close to the main defect to be closed with a single device. Only two of these had been detected on the transthoracic study. In the remaining 15 of 56 patients, transcatheter closure was deemed unsuitable. In 9 patients, this was due to the limitation of the size of the device available during the period of study, this representing a relative contraindication. In the remaining 6 (10.7%), transcatheter closure was not performed because multiple defects were too far apart to be closed with a single device in 3 patients, two patients were noted to have a sinus venosus defect, and another was noted to have anomalous connection of the right upper pulmonary vein to the right atrium. Excluding patients contraindicated due to the size of the defect alone, transesophageal echocardiography provided extra information in one-tenth of our patients, which altered the decision regarding management.

    CONCLUSION: Transesophageal echocardiography is indispensable in the evaluation of patients undergoing transcatheter closure of atrial septal defect.

  10. Leong MC, Alwi M
    Cardiol Young, 2021 May 31.
    PMID: 34053471 DOI: 10.1017/S1047951121001980
    Device occlusion of perimembranous ventricular septal defect is gaining popularity with the emergence of newer, softer occluders and improved technical know-how. We report a 26-year-old lady with a moderate size perimembranous ventricular septal defect who had a new onset of bundle branch block shortly after device closure. The patient subsequently developed a complete atrio-ventricular heart block.
  11. Alwi M, Budi RR, Mood MC, Leong MC, Samion H
    Cardiol Young, 2013 Apr;23(2):197-202.
    PMID: 22640635 DOI: 10.1017/S1047951112000595
    Objective: To determine the feasibility and safety of the Conquest Pro wire as an alternative to radiofrequency wire for perforation of atretic pulmonary valve and subsequent balloon dilatation and patent ductus arteriosus stenting in patients with pulmonary atresia with intact ventricular septum.
    Background: Radiofrequency valvotomy and balloon dilatation has become the standard of care for pulmonary atresia with intact ventricular septum in many institutions today.
    Methods: We report eight consecutive patients in whom we used the Conquest Pro coronary guidewire, a stiff wire normally reserved for revascularisation of coronary lesions with chronic total occlusion, for perforation of atretic pulmonary valve and subsequent balloon dilatation, and stenting of the patent ductus arteriosus.
    Results: Perforation of atretic pulmonary valve was successful in seven out of eight cases. Radiofrequency valvotomy was employed after failure of perforation by the Conquest Pro wire in one case where the right ventricular outflow tract was broad based and tapered towards the pulmonary valve, and was heavily trabeculated. Failure of the Conquest Pro wire to perforate the pulmonary valve plate was mainly attributed by the failure to engage the wire at the correct position.
    Conclusion: The Conquest Pro wire for perforation and subsequent interventions in the more straightforward cases of pulmonary atresia with intact ventricular septum is effective and safe, simplifying the entire procedure. However, the radiofrequency generator and wires remain essential tools in the paediatric interventional catheter laboratory.
  12. Abdul Latiff H, Gopal AR, Hidayat ZF, Haranal M, Borhanuddin BK, Alwi M, et al.
    Cardiol Young, 2023 Nov;33(11):2243-2251.
    PMID: 36651340 DOI: 10.1017/S1047951122004218
    BACKGROUND: The objective was to study the ductus arteriosus morphology in duct-dependent pulmonary circulation and its pattern in different ventricle morphology using CT angiography.

    METHOD: From January 2013 to December 2015, patients aged 6 months and below with duct-dependent pulmonary circulation underwent CT angiography to delineate the ductus arteriosus origin, tortuosity, site of insertion, and pulmonary artery anatomy. The ductus arteriosus were classified into type I, IIa, IIb, and III based on its site of origin, either from descending aorta, distal arch, proximal arch, or subclavian artery, respectively.

    RESULTS: A total of 114 patients and 116 ductus arteriosus (two had bilateral ductus arteriosus) were analysed. Type I, IIa, IIb, and III ductus arteriosus were seen in 13 (11.2 %), 71 (61.2%), 21 (18.1%), and 11 (9.5%), respectively. Tortuous ductus arteriosus was found in 38 (32.7%), which was commonly seen in single ventricular lesions. Ipsilateral and bilateral branch pulmonary artery stenosis was seen in 68 (59.6%) and 6 (5.3%) patients, respectively. The majority of patients with pulmonary atresia intact ventricular septum had type I (54.4%) and non-tortuous ductus arteriosus, while those with single and biventricular lesions had type II ductus arteriosus (84.9% and 89.7%, respectively). Type III ductus arteriosus was more common in biventricular lesions (77.8%).

    CONCLUSIONS: Ductus arteriosus in duct-dependent pulmonary circulation has a diverse morphology with a distinct origin and tortuosity pattern in different types of ventricular morphology. CT may serve as an important tool in case selection and pre-procedural planning for ductal stenting.

  13. Kishi K, Jarutach J, Ooi YK, Wong NL, Che Mood M, Kandhavello G, et al.
    Cardiol Young, 2023 Aug;33(8):1359-1366.
    PMID: 35950412 DOI: 10.1017/S104795112200244X
    INTRODUCTION: Current guidelines discourage shunt closure in patients with pulmonary vascular resistance index >8 Wood units x m2. The study examined the long-term outcome of patients over 15 years old, with pulmonary vascular resistance index >8 Wood units x m2 and patent ductus arteriosus.

    MATERIALS AND METHODS: This was a multi-institutional, retrospective study involving all consecutive patients (>15 years old) with patent ductus arteriosus and severe pulmonary hypertension. Patients who had patent ductus arteriosus closure were divided into the Good (no death or hospital admissions due to worsening pulmonary hypertension) and the Poor Outcome groups and these groups were compared.

    RESULTS: Thirty-seven patients [male: 9 (24.3%); mean age: 30.49 ± 9.56 years; median follow-up: 3 (IQR: 1.5,10) years] were included from four centers. Twenty-two patients who underwent patent ductus arteriosus closure, 15 (71.4%) had good outcomes while 7 (28.6%) had poor outcomes. Pulmonary vascular resistance index and pulmonary to systemic resistance ratio (Rp:Rs) were lower in the Good Outcome Group (14.35 ± 1.66 Wood units x m2 vs. 20.07 ± 2.44; p = 0.033 and 0.44 ± 0.16 vs. 1.08 ± 1.21; p = 0.042). Haemoglobin concentrations (<14.3 g/dL) were associated with good long-term outcomes in the Closed Group.

    CONCLUSIONS: Patients with patent ductus arteriosus with severe pulmonary hypertension have a dismal outcome with or without closure. High haemoglobin levels at the time of occlusion predict a worse outcome for patients with patent ductus arteriosus and pulmonary hypertension.

  14. Leong MC, Hoo XY, Alwi M
    Cardiol Young, 2024 Jan;34(1):228-231.
    PMID: 38073568 DOI: 10.1017/S1047951123004055
    Amplatzer Vascular Plug IV (Abbott, USA) is usually used for the occlusion of abnormal tortuous vessels and has not been tried for the transcatheter closure of perimembranous ventricular septal defects with wind-sock morphology. Here, we report on three successful cases of perimembranous ventricular septal defect transcatheter closure using Amplatzer Vascular Plug IV. We did not observe residual shunting or new onset of complications during follow up. These preliminary positive results advocate the application and suitability of Amplatzer Vascular Plug IV for closing wind-sock-like perimembranous ventricular septal defects.
  15. Abdelbasit MA, Alwi M, Kandavello G, Che Mood M, Samion H, Hijazi ZM
    Catheter Cardiovasc Interv, 2015 Jul;86(1):94-9.
    PMID: 25675888 DOI: 10.1002/ccd.25878
    OBJECTIVES: To evaluate the feasibility, safety, and efficacy of the Occlutech® PDA occluder for closure of patent ductus arteriosus (PDA).

    BACKGROUND: The Occlutech® PDA occluder is novel, self-shaping Nitinol wire device with PET (polyethylene terephthalate) patches integrated into the shank of the device to assure a better obturation of the ductus. The Occlutech® PDA occluder has undergone two design modifications.

    METHODS: A prospective, non-randomized pilot study was started in November 2011. Thirty-three patients were included until April 2013. Patients weighing <6 kg or those with associated cardiac anomalies that required surgery were excluded. All patients were followed up by transthoracic echocardiography at 24 hr, 30 days, 90 days, 180 days, and 360 days after implantation. Residual shunt, left pulmonary artery (LPA) and descending aortic velocities were among the parameters assessed. All occluders were delivered via 6-8 F long sheaths and PDA closures were performed following standard techniques.

    RESULTS: Thirty three patients (20 female/13 male), with a median age of 2 years (6 month to 38 years), and median weight of 9.3 kg (6-69.2 kg) were included. The narrowest median PDA diameter was 3mm (1.8-5.8 mm). All the 33 patients were closed successfully using Occlutech ductal occluder, 16 patients (48.4%) had immediate and complete closure on angiography. Within 24 hr, color Doppler revealed complete closure in 27patients (81.8%), 32patients (97%) at 30 days, and in 100% of patients at 90 days. All patients with a large PDA had immediate residual shunt which was closed at the 90-day follow-up. There was no device embolization, hemolysis, or obstruction to the LPA or descending aorta.

    CONCLUSION: The new Occlutech® PDA is safe and effective. In patients with a large PDA complete closure tended to take longer time.

  16. Abdul Aziz B, Alwi M
    Catheter Cardiovasc Interv, 1999 Oct;48(2):191-3.
    PMID: 10506777
    We report a case of a 14-month-old-infant with severe congenital mitral stenosis who presented with pulmonary oedema, acute renal failure and haemodynamic instability. Balloon dilatation was successfully performed under fluoroscopic and transesophageal echocardiographic guidance. Cathet. Cardiovasc. Intervent. 48:191-193, 1999.
  17. Tan JWY, Alwi M, Siew ELL, Samion H
    Catheter Cardiovasc Interv, 2021 Oct;98(4):738-742.
    PMID: 34143549 DOI: 10.1002/ccd.29838
    Ductal stenting in patients with duct-dependent pulmonary circulation has allowed growth of pulmonary arteries prior to definitive surgical procedures. Intraprocedural stent thrombosis (IPST) of the arterial duct is a life-threatening complication as it leads to total circulatory collapse. Previous reports have described use of tissue plasminogen activators in infants for less emergent settings. We report three infants with IPST and the use of tenecteplase to overcome this. Also discussed are the predisposing mechanisms in each scenario and a possibility of direct catheter-guided tenecteplase administration. Judicious use of tenecteplase can be life-saving and rapid access to this drug may obviate the need for emergency extracorporeal life support.
  18. Alwi M
    Catheter Cardiovasc Interv, 2006 May;67(5):679-86.
    PMID: 16572430 DOI: 10.1002/ccd.20672
    Pulmonary atresia with intact ventricular septum (PAIVS) is a disease with remarkable morphologic variability, affecting not only the pulmonary valve but also the tricuspid valve, the RV cavity and coronary arteries. With advances in interventional techniques and congenital heart surgery, the management of PAIVS continues to evolve. This review is an attempt at providing a practical approach to the management of this disease. The basis of our approach is morphologic classification as derived from echocardiography and angiography. Group A, patients with good sized RV and membranous atresia, the primary procedure at presentation is radiofrequency (RF) valvotomy. Often it is the only procedure required in this group with the most favourable outcome. Patients with severely hypoplastic RV (Group C) are managed along the lines of hearts with single ventricle physiology. The treatment at presentation is patent ductus arteriosus (PDA) stenting with balloon atrial septostomy or conventional modified Blalock Taussig (BT) shunt. Bidirectional Glenn shunt may be done 6-12 months later followed by Fontan completion after a suitable interval. Patients in Group B, the intermediate group, are those with borderline RV size, usually with attenuated trabecular component but well developed infundibulum. The treatment at presentation is RF valvotomy and PDA stenting +/- balloon atrial septostomy. Surgical re-interventions are not uncommonly required viz. bidirectional Glenn shunt when the RV fails to grow adequately (11/2 - ventricle repair) and right ventricular outflow tract (RVOT) reconstruction for subvalvar obstruction or small pulmonary annulus. Catheter based interventions viz. repeat balloon dilatation or device closure of patent foramen ovale (PFO) may also be required in some patients.
  19. Gowda ST, Latson L, Sivakumar K, Hiremath G, Crystal M, Law M, et al.
    Circ Cardiovasc Interv, 2021 12;14(12):e009750.
    PMID: 34903033 DOI: 10.1161/CIRCINTERVENTIONS.120.009750
    BACKGROUND: Coronary artery fistulas (CAFs) presenting in infancy are rare, and data regarding postclosure sequelae and follow-up are limited.

    METHODS: A retrospective review of all the neonates and infants (<1 year) was conducted from the CAF registry for CAF treatment. The CAF type (proximal or distal), size, treatment method, and follow-up angiography were reviewed to assess outcomes and coronary remodeling.

    RESULTS: Forty-eight patients were included from 20 centers. Of these, 30 were proximal and 18 had distal CAF; 39 were large, 7 medium, and 2 had small CAF. The median age and weight was 0.16 years (0.01-1) and 4.2 kg (1.7-10.6). Heart failure was noted in 28 of 48 (58%) patients. Transcatheter closure was performed in 24, surgical closure in 18, and 6 were observed medically. Procedural success was 92% and 94 % for transcatheter closure and surgical closure, respectively. Follow-up data were obtained in 34 of 48 (70%) at a median of 2.9 (0.1-18) years. Angiography to assess remodeling was available in 20 of 48 (41%). I. Optimal remodeling (n=10, 7 proximal and 3 distal CAF). II. Suboptimal remodeling (n=7) included (A) symptomatic coronary thrombosis (n=2, distal CAF), (B) asymptomatic coronary thrombosis (n=3, 1 proximal and 2 distal CAF), and (C) partial thrombosis with residual cul-de-sac (n=1, proximal CAF) and vessel irregularity with stenosis (n=1, distal CAF). Finally, (III) persistent coronary artery dilation (n=4). Antiplatelets and anticoagulation were used in 31 and 7 patients post-closure, respectively. Overall, 7 of 10 (70%) with proximal CAF had optimal remodeling, but 5 of 11 (45%) with distal CAF had suboptimal remodeling. Only 1 of 7 patients with suboptimal remodeling were on anticoagulation.

    CONCLUSIONS: Neonates/infants with hemodynamically significant CAF can be treated by transcatheter or surgical closure with excellent procedural success. Patients with distal CAF are at higher risk for suboptimal remodeling. Postclosure anticoagulation and follow-up coronary anatomic evaluation are warranted.

Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links