OBJECTIVES: To determine the diagnostic accuracy (sensitivity and specificity) of ultrasound estimated fetal weight discordance (EFWD) of 20% and 25% using different estimated biometric ultrasound measurements compared with the actual BWD as the reference standard in twin pregnancies.
SEARCH METHODS: The search for this review was performed on 15 March 2019. We searched CENTRAL, MEDLINE (Ovid), Embase (Ovid), seven other databases, conference proceedings, reference lists and contacted experts. There were no language or date restrictions applied to the electronic searches, and no methodological filters to maximize sensitivity.
SELECTION CRITERIA: We selected cohort-type studies with delayed verification that evaluated the accuracy of biometric measurements at ultrasound scanning of twin pregnancies that had been proposed for the diagnosis of estimated BWD, compared to BWD measurements after birth as a reference standard. In addition, we only selected studies that considered twin pregnancies and applied a reference standard for EFWD for the target condition of BWD.
DATA COLLECTION AND ANALYSIS: We screened all titles generated by electronic database searches. Two review authors independently assessed the abstracts of all potentially relevant studies. We assessed the identified full papers for eligibility, and extracted data to create 2 × 2 tables. Two review authors independently performed quality assessment using the QUADAS-2 tool. We excluded studies that did not report data in sufficient detail to construct 2 × 2 tables, and where this information was not available from the primary investigators. We assessed the certainty of the evidence using the GRADE approach.
MAIN RESULTS: We included 39 eligible studies with a median study sample size of 140. In terms of risk of bias, there were many unclear statements regarding patient selection, index test and use of proper reference standard. Twenty-one studies (53%) were of methodological concern due to flow and timing. In terms of applicability, most studies were of low concern. Ultrasound for diagnosis of BWD in twin pregnancies at 20% cut-off Twenty-two studies provided data for a BWD of 20% and the summary estimate of sensitivity was 0.51 (95% CI 0.42 to 0.60), and the summary estimate of specificity was 0.91 (95% CI 0.89 to 0.93) (8005 twin pregnancies; very low-certainty evidence). Ultrasound for diagnosis of BWD in twin pregnancies at 25% cut-off Eighteen studies provided data using a BWD discordance of 25%. The summary estimate of sensitivity was 0.46 (95% CI 0.26 to 0.66), and the summary estimate of specificity was 0.93 (95% CI 0.89 to 0.96) (6471 twin pregnancies; very low-certainty evidence). Subgroup analyses were possible for both BWD of 20% and 25%. The diagnostic accuracy did not differ substantially between estimation by abdominal circumference and femur length but femur length had a trend towards higher sensitivity and specificity. Subgroup analyses were not possible by sex of twins, chorionicity or gestational age due to insufficient data.
AUTHORS' CONCLUSIONS: Very low-certainty evidence suggests that EFWD identified by ultrasound has low sensitivity but good specificity in detecting BWD in twin pregnancies. There is uncertain diagnostic value of EFWD; this review suggests there is insufficient evidence to support this index as the sole measure for clinical decision making to evaluate the prognosis of twins with growth discordance. The diagnostic accuracy of other measures including amniotic fluid index and umbilical artery Doppler resistive indices in combination with ultrasound for clinical intervention requires evaluation. Future well-designed studies could also evaluate the impact of chorionicity, sex and gestational age in the diagnostic accuracy of ultrasound for EFWD.
OBJECTIVES: To assess the effect of mother-infant rooming-in versus separation on the duration of breastfeeding (exclusive and total duration of breastfeeding).
SEARCH METHODS: We searched the Cochrane Pregnancy and Childbirth Group's Trials Register (30 May 2016) and reference lists of retrieved studies.
SELECTION CRITERIA: Randomised or quasi-randomised controlled trials (RCTs) investigating the effect of mother-infant rooming-in versus separate care after hospital birth or at home on the duration of breastfeeding, proportion of breastfeeding at six months and adverse neonatal and maternal outcomes.
DATA COLLECTION AND ANALYSIS: Two review authors independently assessed the studies for inclusion and assessed trial quality. Two review authors extracted data. Data were checked for accuracy. We assessed the quality of the evidence using the GRADE approach.
MAIN RESULTS: We included one trial (involving 176 women) in this review. This trial included four groups with a factorial design. The factorial design took into account two factors, i.e. infant location in relation to the mother and the type of infant apparel. We combined three of the groups as the intervention (rooming-in) group and the fourth group acted as the control (separate care) and we analysed the results as a single pair-wise comparison. Primary outcomesThe primary outcome, duration of any breastfeeding, was reported by authors as median values because the distribution was found to be skewed. They reported the overall median duration of any breastfeeding to be four months, with no difference found between groups. Duration of exclusive breastfeeding and the proportion of infants being exclusively breastfed at six months of age was not reported in the trial. There was no difference found between the two groups in the proportion of infants receiving any breastfeeding at six months of age (risk ratio (RR) 0.84, 95% confidence interval (CI) 0.51 to 1.39; one trial; 137 women; low-quality evidence). Secondary outcomesThe mean frequency of breastfeeds per day on day four postpartum for the rooming-in group was 8.3 (standard deviation (SD) 2.2), slightly higher than the separate care group, i.e. seven times per day. However, between-group comparison of this outcome was not appropriate since every infant in the separate care group was breastfed at a fixed schedule of seven times per day (SD = 0) resulting in no estimable comparison. The rate of exclusive breastfeeding on day four postpartum before discharge from hospital was significantly higher in the rooming-in group 86% (99 of 115) compared with separate care group, 45% (17 of 38), (RR 1.92; 95% CI 1.34 to 2.76; one trial, 153 women; low-quality evidence). None of our other pre-specified secondary outcomes were reported.
AUTHORS' CONCLUSIONS: We found little evidence to support or refute the practice of rooming-in versus mother-infant separation. Further well-designed RCTs to investigate full mother-infant rooming-in versus partial rooming-in or separate care including all important outcomes are needed.
OBJECTIVES: To evaluate all randomized controlled trials (RCTs) that have assessed strategies for treatment and prevention of heavy menstrual bleeding or pain associated with IUD use, for example, pharmacotherapy and alternative therapies.
SEARCH METHODS: We searched CENTRAL, MEDLINE, Embase and CINAHL to January 2021.
SELECTION CRITERIA: We included RCTs in any language that tested strategies for treatment or prevention of heavy menstrual bleeding or pain associated with IUD (Cu IUD, LNG IUD or other IUD) use. The comparison could be no intervention, placebo or another active intervention.
DATA COLLECTION AND ANALYSIS: Two review authors independently assessed trials for inclusion and risk of bias, and extracted data. Primary outcomes were volume of menstrual blood loss, duration of menstruation and painful menstruation. We used a random-effects model in all meta-analyses. Review authors assessed the certainty of evidence using GRADE.
MAIN RESULTS: This review includes 21 trials involving 3689 participants from middle- and high-income countries. Women were 18 to 45 years old and either already using an IUD or had just had one placed for contraception. The included trials examined NSAIDs and other interventions. Eleven were treatment trials, of these seven were on users of the Cu IUD, one on LNG IUD and three on an unknown type. Ten were prevention trials, six focused on Cu IUD users, and four on LNG IUD users. Sixteen trials had high risk of detection bias due to subjective assessment of pain and bleeding. Treatment of heavy menstrual bleeding Cu IUD Vitamin B1 resulted in fewer pads used per day (mean difference (MD) -7.00, 95% confidence interval (CI) -8.50 to -5.50) and fewer bleeding days (MD -2.00, 95% CI -2.38 to -1.62; 1 trial; 110 women; low-certainty evidence) compared to placebo. The evidence is very uncertain about the effect of naproxen on the volume of menstruation compared to placebo (odds ratio (OR) 0.09, 95% CI 0.00 to 1.78; 1 trial, 40 women; very low-certainty evidence). Treatment with mefenamic acid resulted in less volume of blood loss compared to tranexamic acid (MD -64.26, 95% CI -105.65 to -22.87; 1 trial, 94 women; low-certainty evidence). However, there was no difference in duration of bleeding with treatment of mefenamic acid or tranexamic acid (MD 0.08 days, 95% CI -0.27 to 0.42, 2 trials, 152 women; low-certainty evidence). LNG IUD The use of ulipristal acetate in LNG IUD may not reduce the number of bleeding days in 90 days in comparison to placebo (MD -9.30 days, 95% CI -26.76 to 8.16; 1 trial, 24 women; low-certainty evidence). Unknown IUD type Mefenamic acid may not reduce volume of bleeding compared to Vitex agnus measured by pictorial blood assessment chart (MD -2.40, 95% CI -13.77 to 8.97; 1 trial; 84 women; low-certainty evidence). Treatment of pain Cu IUD Treatment with tranexamic acid and sodium diclofenac may result in little or no difference in the occurrence of pain (OR 1.00, 95% CI 0.06 to 17.25; 1 trial, 38 women; very low-certainty evidence). Unknown IUD type Naproxen may reduce pain (MD 4.10, 95% CI 0.91 to 7.29; 1 trial, 33 women; low-certainty evidence). Prevention of heavy menstrual bleeding Cu IUD We found very low-certainty evidence that tolfenamic acid may prevent heavy bleeding compared to placebo (OR 0.54, 95% CI 0.34 to 0.85; 1 trial, 310 women). There was no difference between ibuprofen and placebo in blood volume reduction (MD -14.11, 95% CI -36.04 to 7.82) and duration of bleeding (MD -0.2 days, 95% CI -1.40 to 1.0; 1 trial, 28 women, low-certainty evidence). Aspirin may not prevent heavy bleeding in comparison to paracetamol (MD -0.30, 95% CI -26.16 to 25.56; 1 trial, 20 women; very low-certainty evidence). LNG IUD Ulipristal acetate may increase the percentage of bleeding days compared to placebo (MD 9.50, 95% CI 1.48 to 17.52; 1 trial, 118 women; low-certainty evidence). There were insufficient data for analysis in a single trial comparing mifepristone and vitamin B. There were insufficient data for analysis in the single trial comparing tranexamic acid and mefenamic acid and in another trial comparing naproxen with estradiol. Prevention of pain Cu IUD There was low-certainty evidence that tolfenamic acid may not be effective to prevent painful menstruation compared to placebo (OR 0.71, 95% CI 0.44 to 1.14; 1 trial, 310 women). Ibuprofen may not reduce menstrual cramps compared to placebo (OR 1.00, 95% CI 0.11 to 8.95; 1 trial, 20 women, low-certainty evidence).
AUTHORS' CONCLUSIONS: Findings from this review should be interpreted with caution due to low- and very low-certainty evidence. Included trials were limited; the majority of the evidence was derived from single trials with few participants. Further research requires larger trials and improved trial reporting. The use of vitamin B1 and mefenamic acid to treat heavy menstruation and tolfenamic acid to prevent heavy menstruation associated with Cu IUD should be investigated. More trials are needed to generate evidence for the treatment and prevention of heavy and painful menstruation associated with LNG IUD.
OBJECTIVES: To assess the effect of restricted versus unrestricted pacifier use in healthy full-term newborns whose mothers have initiated breastfeeding and intend to exclusively breastfeed, on the duration of breastfeeding, other breastfeeding outcomes and infant health.
SEARCH METHODS: We searched the Cochrane Pregnancy and Childbirth Group's Trials Register (30 June 2016) and reference lists of retrieved studies.
SELECTION CRITERIA: Randomised and quasi-randomised controlled trials comparing restricted versus unrestricted pacifier use in healthy full-term newborns who have initiated breastfeeding.
DATA COLLECTION AND ANALYSIS: Two review authors independently assessed trials for inclusion and risk of bias, extracted data and checked them for accuracy. The quality of the evidence was assessed using the GRADE approach.
MAIN RESULTS: We found three trials (involving 1915 babies) for inclusion in the review, but have included only two trials (involving 1302 healthy full-term breastfeeding infants) in the analysis. Meta-analysis of the two combined studies showed that pacifier use in healthy breastfeeding infants had no significant effect on the proportion of infants exclusively breastfed at three months (risk ratio (RR) 1.01; 95% confidence interval (CI) 0.96 to 1.07, two studies, 1228 infants), and at four months of age (RR 1.01; 95% CI 0.94 to 1.09, one study, 970 infants, moderate-quality evidence), and also had no effect on the proportion of infants partially breastfed at three months (RR 1.00; 95% CI 0.98 to 1.02, two studies, 1228 infants), and at four months of age (RR 0.99; 95% CI 0.97 to 1.02, one study, 970 infants). None of the included trials reported data on the other primary outcomes, i.e. duration of partial or exclusive breastfeeding, or secondary outcomes: breastfeeding difficulties (mastitis, cracked nipples, breast engorgement); infant's health (dental malocclusion, otitis media, oral candidiasis; sudden infant death syndrome (SIDS)); maternal satisfaction and level of confidence in parenting. One study reported that avoidance of pacifiers had no effect on cry/fuss behavior at ages four, six, or nine weeks and also reported no effect on the risk of weaning before age three months, however the data were incomplete and so could not be included for analysis.
AUTHORS' CONCLUSIONS: Pacifier use in healthy term breastfeeding infants, started from birth or after lactation is established, did not significantly affect the prevalence or duration of exclusive and partial breastfeeding up to four months of age. Evidence to assess the short-term breastfeeding difficulties faced by mothers and long-term effect of pacifiers on infants' health is lacking.