Affiliations 

  • 1 MPH Program, Department of Public Health and Community Medicine, Tufts University School of Medicine, Michigan, USA
  • 2 Department of Paediatrics, RCSI & UCD Malaysia Campus (formerly Penang Medical College), George Town, Malaysia
  • 3 Department of Obstetrics and Gynaecology, Regency Specialist Hospital, Johor Bahru, Malaysia
  • 4 Servizio Immunotrasfusionale, Azienda Unita' Sanitaria Locale Umbria 2, Foligno (PG), Italy
  • 5 Department of Midwifery/Nursing, Golestan University of Medical Sciences, Gorgan, Iran
  • 6 School of Health Sciences, Central Michigan University, Mt. Pleasant, Michigan, USA
  • 7 Section of Neonatology, Department of Pediatrics, Baylor College of Medicine, Houston, Texas, USA
Cochrane Database Syst Rev, 2021 03 09;3:CD012553.
PMID: 33686672 DOI: 10.1002/14651858.CD012553.pub2

Abstract

BACKGROUND: There is a need to standardize monitoring in obstetric research of twin pregnancies. Identification of birth weight discordance (BWD), defined as a difference in the birth weights of twins, is a well-documented phenomenon in twin pregnancies. Ultrasound for the diagnosis of BWD informs complex decision making including whether to intervene medically (via laser photo coagulation) or deliver the twins to avoid fetal morbidities or even death. The question is, how accurate is this measurement?

OBJECTIVES: To determine the diagnostic accuracy (sensitivity and specificity) of ultrasound estimated fetal weight discordance (EFWD) of 20% and 25% using different estimated biometric ultrasound measurements compared with the actual BWD as the reference standard in twin pregnancies.

SEARCH METHODS: The search for this review was performed on 15 March 2019. We searched CENTRAL, MEDLINE (Ovid), Embase (Ovid), seven other databases, conference proceedings, reference lists and contacted experts. There were no language or date restrictions applied to the electronic searches, and no methodological filters to maximize sensitivity.

SELECTION CRITERIA: We selected cohort-type studies with delayed verification that evaluated the accuracy of biometric measurements at ultrasound scanning of twin pregnancies that had been proposed for the diagnosis of estimated BWD, compared to BWD measurements after birth as a reference standard. In addition, we only selected studies that considered twin pregnancies and applied a reference standard for EFWD for the target condition of BWD.

DATA COLLECTION AND ANALYSIS: We screened all titles generated by electronic database searches. Two review authors independently assessed the abstracts of all potentially relevant studies. We assessed the identified full papers for eligibility, and extracted data to create 2 × 2 tables. Two review authors independently performed quality assessment using the QUADAS-2 tool. We excluded studies that did not report data in sufficient detail to construct 2 × 2 tables, and where this information was not available from the primary investigators. We assessed the certainty of the evidence using the GRADE approach.

MAIN RESULTS: We included 39 eligible studies with a median study sample size of 140. In terms of risk of bias, there were many unclear statements regarding patient selection, index test and use of proper reference standard. Twenty-one studies (53%) were of methodological concern due to flow and timing. In terms of applicability, most studies were of low concern. Ultrasound for diagnosis of BWD in twin pregnancies at 20% cut-off Twenty-two studies provided data for a BWD of 20% and the summary estimate of sensitivity was 0.51 (95% CI 0.42 to 0.60), and the summary estimate of specificity was 0.91 (95% CI 0.89 to 0.93) (8005 twin pregnancies; very low-certainty evidence). Ultrasound for diagnosis of BWD in twin pregnancies at 25% cut-off Eighteen studies provided data using a BWD discordance of 25%. The summary estimate of sensitivity was 0.46 (95% CI 0.26 to 0.66), and the summary estimate of specificity was 0.93 (95% CI 0.89 to 0.96) (6471 twin pregnancies; very low-certainty evidence). Subgroup analyses were possible for both BWD of 20% and 25%. The diagnostic accuracy did not differ substantially between estimation by abdominal circumference and femur length but femur length had a trend towards higher sensitivity and specificity. Subgroup analyses were not possible by sex of twins, chorionicity or gestational age due to insufficient data.

AUTHORS' CONCLUSIONS: Very low-certainty evidence suggests that EFWD identified by ultrasound has low sensitivity but good specificity in detecting BWD in twin pregnancies. There is uncertain diagnostic value of EFWD; this review suggests there is insufficient evidence to support this index as the sole measure for clinical decision making to evaluate the prognosis of twins with growth discordance. The diagnostic accuracy of other measures including amniotic fluid index and umbilical artery Doppler resistive indices in combination with ultrasound for clinical intervention requires evaluation. Future well-designed studies could also evaluate the impact of chorionicity, sex and gestational age in the diagnostic accuracy of ultrasound for EFWD.

* Title and MeSH Headings from MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine.