Displaying all 2 publications

Abstract:
Sort:
  1. Gabrielle Sutanto L, Sabilla S, Wardhana BY, Ramadani A, Sari AP, Anjani QK, et al.
    RSC Adv, 2024 Sep 04;14(39):28927-28942.
    PMID: 39263434 DOI: 10.1039/d4ra03585b
    Theophylline (TP) is a methylxanthine derivative, which serves as a valuable compound in treating respiratory disorders and acts as a bronchodilator agent. However, TP has a limited therapeutic range (20-100 μmol L-1), demanding precise monitoring to prevent potential drug toxicity even with slight level fluctuations during treatment. Thus, to overcome this limitation, electrochemical methods have been extensively used due to their efficacy in achieving sensitivity, selectivity, and accuracy. In the context of electrochemical sensors, nanocarbon-based materials have gained widespread recognition for their extensive applications. Therefore, this review aims to explore the latest advancements in carbon-based electrodes particularly used for the precise determination of TP through electrochemical methods. The results are expected to provide insights into the profound significance of the methods in enhancing the accuracy and sensitivity for the detection of TP.
  2. Jiwanti PK, Putri IH, Kadja GTM, Einaga Y, Sutanto LG, Wafiroh S, et al.
    J Food Drug Anal, 2024 Sep 13;32(3):348-357.
    PMID: 39636777 DOI: 10.38212/2224-6614.3517
    Overuse of levofloxacin (LEV) is often associated with bacterial resistance and serious health problems, underscoring the need for reliable sensing and monitoring of LEV molecules. Therefore, this study aimed to investigate LEV using boron-doped diamond (BDD) and boron-doped diamond modified with MXene (Ti3C2TX) (BDD-MXene) electrode. The successful deposition of MXene on the BDD surface was confirmed using scanning electron microscope (SEM). Cyclic voltammetry (CV) and square wave voltammetry (SWV) methods were also applied to evaluate the electrochemical behavior. The results showed that both electrodes had a linear response in the range of 30-100 μM. The limit of detection (LOD) and limit of quantitation (LOQ) were found to be 1.0 × 10-6 M and 3.37 × 10-6 M for bare-BDD, while on BDD-MXene, the values were 3.90 × 10-7 M and 1.30 × 10-6 M, respectively. Furthermore, both electrodes showed good responses on selectivity tests with glucose and another fluoroquinolone antibiotic such as ciprofloxacin. The results also indicated good precision with %RSD less than 5%. In real sample applications using wastewater, bare-BDD and BDD-MXene produced excellent %recovery of 92.96% and 101.29%, respectively.
Related Terms
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links