Displaying all 2 publications

Abstract:
Sort:
  1. Kandar MZ, Bhari IB
    Mutat Res, 1996 Apr 13;351(2):157-61.
    PMID: 8622709
    The usefulness of peripheral human lymphocytes as a bioindicator for ionizing radiation effect was tested in a survey of Malaysian workers in two industries producing technologically enhanced naturally occurring radioactive material (TENORM). Workers in amang processing plants who have been with the plant for an average of 12.9 years and who were exposed to radioactive dust showed significantly higher frequencies of chromosomal aberration compared to control and even ilmenite-processing workers. Such frequency was not significantly different between workers in ilmenite-processing plant and control. The differences in duration of employment, occupational hygiene, together with the difference in the percentage of 'old' and 'new' aberrations among the groups sampled were used to explain the high chromosomal aberration frequency among amang workers. The presence of significantly high chromosome damage (dicentrics and fragments) in workers who were chronically exposed to doses below 50 mSv per year or 20 mSv per year averaged over 5 years (ICRP, 1991) provided additional experimental data on the dose-effect relationship at these low-dose ranges. The results confirm the usefulness of using human lymphocytes as a bioindicator for chronic exposure to ionizing radiation and in cases where physical radiation detectors are not available.
  2. Kandar MZ, Nimlyat PS, Abdullahi MG, Dodo YA
    Heliyon, 2019 Jul;5(7):e02077.
    PMID: 31360788 DOI: 10.1016/j.heliyon.2019.e02077
    External shading geometry on buildings has been found to contribute substantially to reducing energy consumption for cooling. This study examines the effect of inclined wall self-shading strategy on heat gain in an office building. Field measurement of environmental variables such as ambient temperature, relative humidity, dew point, and wet bulb temperature was carried out in a case study inclined wall self-shading office building located in Putrajaya, Malaysia. The results of the validation of ApacheSim simulation software tool against the measured environmental variables indicated significant reliability having Pearson correlations ranging from 0.56 to 0.90. In establishing the relationship between different inclined wall strategies to the amount of heat gain, modification of the inclined wall self-shading projection (SSP) was modelled and experimented using ApacheSim simulation. Findings from the analysis revealed a relationship between heat gains into a building space and self-shading projection (SSP), as heat gains tend to reduce with increased SSP. From the findings, the optimum inclination angle of self-shading for effective heat gain reduction is based on a 45% self-shading projection. The application of inclined wall self-shading strategy in buildings would, therefore, bring about a reduction in heat gain, which invariably reduces energy consumption for cooling.
Related Terms
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links