Displaying all 2 publications

Abstract:
Sort:
  1. Mohd Norsuddin N, Mello-Thoms C, Reed W, Lewis S
    Asian Pac J Cancer Prev, 2019 Feb 26;20(2):537-543.
    PMID: 30803217
    Rationale and objectives: Target recall rates are often used as a performance indicator in mammography screening
    programs with the intention of reducing false positive decisions, over diagnosis and anxiety for participants. However,
    the relationship between target recall rates and cancer detection is unclear, especially when readers are directed to
    adhere to a predetermined rate. The purpose of this study was to explore the effect of setting different recall rates on
    radiologist’s performance. Materials and Methods: Institutional ethics approval was granted and informed consent
    was obtained from each participating radiologist. Five experienced breast imaging radiologists read a single test set
    of 200 mammographic cases (20 abnormal and 180 normal). The radiologists were asked to identify each case that
    they required to be recalled in three different recall conditions; free recall, 15% and 10% and mark the location of any
    suspicious lesions. Results: Wide variability in recall rates was observed when reading at free recall, ranging from
    18.5% to 34.0%. Readers demonstrated significantly reduced performance when reading at prescribed recall rates,
    with lower sensitivity (H=12.891, P=0.002), case location sensitivity (H=12.512, P=0.002) and ROC AUC (H=11.601,
    P=0.003) albeit with an increased specificity (H=12.704, P=0.002). However, no significant changes were evident in
    lesion location sensitivity (H=1.982, P=0.371) and JAFROC FOM (H=1.820, P=0.403). Conclusion: In this laboratory
    study, reducing the number of recalled cases to 10% significantly reduced radiologists’ performance with lower detection
    sensitivity, although a significant improvement in specificity was observed.
  2. Mohd Norsuddin N, Mello-Thoms C, Reed W, Rickard M, Lewis S
    Br J Radiol, 2017 Aug;90(1076):20170048.
    PMID: 28621548 DOI: 10.1259/bjr.20170048
    OBJECTIVE: This study investigated whether certain mammographic appearances of breast cancer are missed when radiologists read at lower recall rates.

    METHODS: 5 radiologists read 1 identical test set of 200 mammographic (180 normal cases and 20 abnormal cases) 3 times and were requested to adhere to 3 different recall rate conditions: free recall, 15% and 10%. The radiologists were asked to mark the locations of suspicious lesions and provide a confidence rating for each decision. An independent expert radiologist identified the various types of cancers in the test set, including the presence of calcifications and the lesion location, including specific mammographic density.

    RESULTS: Radiologists demonstrated lower sensitivity and receiver operating characteristic area under the curve for non-specific density/asymmetric density (H = 6.27, p = 0.04 and H = 7.35, p = 0.03, respectively) and mixed features (H = 9.97, p = 0.01 and H = 6.50, p = 0.04, respectively) when reading at 15% and 10% recall rates. No significant change was observed on cancer characterized with stellate masses (H = 3.43, p = 0.18 and H = 1.23, p = 0.54, respectively) and architectural distortion (H = 0.00, p = 1.00 and H = 2.00, p = 0.37, respectively). Across all recall conditions, stellate masses were likely to be recalled (90.0%), whereas non-specific densities were likely to be missed (45.6%).

    CONCLUSION: Cancers with a stellate mass were more easily detected and were more likely to continue to be recalled, even at lower recall rates. Cancers with non-specific density and mixed features were most likely to be missed at reduced recall rates. Advances in knowledge: Internationally, recall rates vary within screening mammography programs considerably, with a range between 1% and 15%, and very little is known about the type of breast cancer appearances found when radiologists interpret screening mammograms at these various recall rates. Therefore, understanding the lesion types and the mammographic appearances of breast cancers that are affected by readers' recall decisions should be investigated.