Displaying 1 publication

Abstract:
Sort:
  1. Leman, A.M., Supaat Zakaria, Jamaludin, M.F.Z., Feriyanto, D., Azmarini A. Nazri, Rahman, K.A.
    MyJurnal
    Local Exhaust Ventilation (LEV) is required to absorbed the chemical and at the same time to maintain the air quality. This
    study is purposed to create new design of LEV system that believe can remove air contaminants in the chemical store buildings. This
    research was conducted using two (2) types of LEV system which are 4 air-inlets LEV (type 1) and 3 air-inlets LEV (type 2). That LEV
    has been simulated using ANSYS FLUENT software for their air flow performances. LEV material and the cost of production were
    considered parameter for fabricating and effectiveness of LEV system. Results show that air velocity in LEV type 1 was gradually
    uniform throughout its ducting network but it increased at the 90º bend section with a maximum air velocity of 31.054 m/s. In the LEV
    type 2, the air flow simulations depicted uniformity velocity values of 8.12 m/s, 8.58 m/s and 7.69 m/s at every inlet respectively. The
    finding suggests that LEV type 2 was more efficient compared to LEV type 1 due to increasing streamline air velocity.
Related Terms
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links