Displaying publications 1 - 20 of 30 in total

Abstract:
Sort:
  1. Hsien YM, Mustapha M, Hamzah JC, Maskon O, Ken CC, Hamdi CH
    BMC Ophthalmol, 2016;16:32.
    PMID: 27013074 DOI: 10.1186/s12886-016-0209-1
    The purpose of this study was to report case series of retinal artery occlusion (RAO) as one of the significant complication post cardiac intervention.
  2. Lam CK, Sundaraj K, Sulaiman MN, Qamarruddin FA
    BMC Ophthalmol, 2016;16:88.
    PMID: 27296449 DOI: 10.1186/s12886-016-0269-2
    Computer based surgical training is believed to be capable of providing a controlled virtual environment for medical professionals to conduct standardized training or new experimental procedures on virtual human body parts, which are generated and visualised three-dimensionally on a digital display unit. The main objective of this study was to conduct virtual phacoemulsification cataract surgery to compare performance by users with different proficiency on a virtual reality platform equipped with a visual guidance system and a set of performance parameters.
  3. Premsenthil M, Manju R, Thanaraj A, Rahman SA, Kah TA
    BMC Ophthalmol, 2013;13:16.
    PMID: 23601160 DOI: 10.1186/1471-2415-13-16
    To screen for visual impairment in Malaysian preschool children.
  4. Md-Muziman-Syah MM, Muzir NS, Abdul Mutalib H, Ab Halim N
    BMC Ophthalmol, 2021 Oct 25;21(1):378.
    PMID: 34696755 DOI: 10.1186/s12886-021-02145-5
    BACKGROUND: The Quality of Life Impact Refractive Correction (QIRC) questionnaire is a Rasch-validated instrument to assess the quality of life of ametropes with refractive correction. The original QIRC was validated in the United Kingdom. This study aimed to validate the Malay version of the QIRC among refractive correction wearers in Malaysia using Rasch analysis.

    METHODS: The original 20-item QIRC was forward-backward translated into Malay in preparation for the Pilot Malay QIRC. The pilot version was pre-tested on 105 spectacle/contact lens-corrected myopes, and the results were reviewed and cross-culturally adapted to produce the Final Malay QIRC. The final version was self-administered to a new sample of 304 participants. A Rasch analysis was conducted to evaluate the items and response categories of the Pilot and the Final Malay QIRC. Test-retest reliability was also analysed on the Final Malay QIRC.

    RESULTS: Based on the pre-test findings, Rasch analysis revealed a multidimensional scale (functional scale [Items 1 to 13] and emotional scale [Items 14 to 20], which were separated in subsequent analysis), unordered response categories for the functional scale (Category 3 was collapsed into Category 2), one misfit item (Item 3 was removed) and six items required modification (Items 4, 6 to 9, and 12 were reworded and cross-culturally adapted). In the Final Malay QIRC, both the functional and emotional scales had ordered response categories, good person reliability (functional, 0.80; emotional, 0.81) and separation index (functional, 2.01; emotional, 2.06), well-targeted items (targeting precision: functional, 0.28 logits; emotional, 0.08 logits), and satisfactory fit statistics (infit and outfit mean square were less than 1.50 for all items). A noticeable differential item functioning (DIF) between genders was found in Item 18 (DIF contrast, 0.40 logits; p = 0.04). Test-retest reliability analysis demonstrated a high intraclass correlation coefficient (0.94) and Cronbach's alpha (0.97) with a coefficient of repeatability of ±8.14 units.

    CONCLUSIONS: The Malay-translated version of the QIRC has good psychometric characteristics for assessing the quality of life of refractive correction wearers in Malaysia. This translated and cross-culturally adapted Malay QIRC is a valid and reliable instrument that can be used in routine clinical practice.

  5. Lai CC, Wu AL, Chou HD, Teh WM, Chen KJ, Chen YP, et al.
    BMC Ophthalmol, 2020 Mar 21;20(1):116.
    PMID: 32199465 DOI: 10.1186/s12886-020-01393-1
    BACKGROUND: To evaluate the feasibility of a surgical technique using a sub-perfluoro-n-octane (PFO) injection of ocular viscoelastic device (OVD) to stabilize inverted internal limiting membrane (ILM) flap for the treatment of macular hole retinal detachment (MHRD).

    METHODS: This study was a retrospective, consecutive, interventional case series. Patients who underwent MHRD surgery with sub-PFO injection of OVD to stabilize inverted ILM flap onto the macular hole (MH) were reviewed. The color fundus and optical coherence tomography (OCT) images were collected and evaluated. The best-corrected visual acuity (BCVA) before and after surgery were compared as the functional outcome.

    RESULTS: The study included 8 eyes of 8 consecutive patients (mean age: 61.8 ± 7.1 years; mean follow-up period: 9.0 ± 2.5 months). All eyes (100%) achieved successful MH closure; 7 eyes (87.5%) demonstrated complete retinal reattachment, and 1 eye (12.5%) had minimal residual subretinal fluid parafoveally. Of the 8 patients, 7 patients (87.5%) had achieved improvement in BCVA after the primary surgery, whereas 1 eye remained stable. The average BCVA before and after the surgery at the last visit improved from 20/843 (1.63 ± 0.48 logMAR) to 20/200 (1.00 ± 0.39 logMAR) (P = 0.016). Anatomically, near-normal foveal contour was noted in five (62.5%) eyes at the final follow-up.

    CONCLUSIONS: The use of sub-PFO injection of OVD in MHRD surgery could stabilize inverted ILM flaps, achieve good anatomical results and improve postoperative BCVA.

  6. Premsenthil M, Salowi MA, Siew CM, ak Gudom I, Kah T
    BMC Ophthalmol, 2012;12:64.
    PMID: 23241197 DOI: 10.1186/1471-2415-12-64
    To report a case of spontaneous malignant glaucoma in an Asian female. To propose the term "positive vitreous pressure glaucoma" to reflect the pathophysiology, treatment and prognosis of the condition.
  7. Khaw KW, Lam HH, Khang TF, Wan Ab Kadir AJ, Subrayan V
    BMC Ophthalmol, 2014;14:16.
    PMID: 24533465 DOI: 10.1186/1471-2415-14-16
    To report the rate of cystoid macular oedema (CMO) as detected by spectral-domain optical coherence tomography (SD-OCT) after intraoperative complication during phacoemulsification. The secondary objectives include comparing mean macular thickness and best-corrected visual acuity (BCVA) between those who developed postoperative CMO against those who did not.
  8. Embong Z, Wan Hitam WH, Yean CY, Rashid NH, Kamarudin B, Abidin SK, et al.
    BMC Ophthalmol, 2008;8:7.
    PMID: 18445283 DOI: 10.1186/1471-2415-8-7
    The sensitivity and specificity of 18S rRNA polymerase chain reaction (PCR) in the detection of fungal aetiology of microbial keratitis was determined in thirty patients with clinical diagnosis of microbial keratitis.
  9. Pee XK, Low A, Ab Kahar MEPI, Mohamed SO, Chong YJ
    BMC Ophthalmol, 2023 Nov 07;23(1):444.
    PMID: 37932684 DOI: 10.1186/s12886-023-03186-8
    BACKGROUND: To report a rare case of pulmonary and ocular complications with visual loss due to bilateral Purtscher-like retinopathy and paracentral acute middle maculopathy (PAMM) following a hyaluronic acid (HA) filler injection to the breast. Systemic and visual recovery was attained following corticosteroid therapy.

    CASE PRESENTATION: A 27-year-old lady presented with painless blurring of vision in both eyes for 2 weeks following hyaluronic acid breast filler injections by a non-medical practitioner. She was initially admitted to the medical ward for diffuse alveolar haemorrhage and altered sensorium. The presenting visual acuity was counting fingers in both eyes. Bilateral dilated fundus examination showed hyperaemic discs, concentric rim of retinal whitening around macula with patches of polygonal-shaped retinal whitening, generalised cotton-wool spots, tortuous veins, and flame-shaped haemorrhages. Spectral-domain optical coherence tomography (SD-OCT) macula revealed hyper-reflective bands at the inner nuclear layer (INL). Fluorescein angiography demonstrated hot discs, delayed arm-to-retina time, arterial filling, and arterio-venous transit time with staining of the vessels at the posterior pole. She was managed with a tapering dose of systemic corticosteroids. The visual acuity improved to 6/12 over 8 weeks with significant anatomical and functional improvement. Dilated fundus examination showed resolution of initial funduscopy findings. The hyper-reflective bands on the OCT had resolved with subsequent thinning of the INL and disorganisation of retinal inner layers.

    CONCLUSION: Filler injections are in increasing demand and are frequently being performed by non-medical practitioners. Visual loss from non-facial HA fillers is rare. Inadvertent entry of HA into a blood vessel may potentially cause systemic and sight-threatening ocular complications. Good anatomical knowledge and proper injection technique are vital in preventing this unfortunate sequela. There are limited reports on successful visual recovery following various treatment approaches and we hope this case provides valuable insights.

  10. Ho H, Foo J, Li YC, Bobba S, Go C, Chandra J, et al.
    BMC Ophthalmol, 2021 Apr 10;21(1):173.
    PMID: 33838650 DOI: 10.1186/s12886-021-01929-z
    BACKGROUND: To identify prognostic factors determining final visual outcome following open globe injuries.

    METHODS: Retrospective case series of patients presenting to Westmead Hospital, Sydney, Australia with open globe injuries from 1st January 2005 to 31st December 2017. Data collected included demographic information, ocular injury details, management and initial and final visual acuities.

    RESULTS: A total of 104 cases were identified. Predictors of poor final visual outcomes included poor presenting visual acuity (p 

  11. Jasman AA, Shaharuddin B, Noor RA, Ismail S, Ghani ZA, Embong Z
    BMC Ophthalmol, 2010;10:20.
    PMID: 20738840 DOI: 10.1186/1471-2415-10-20
    Despite growing number of intraocular lens power calculation formulas, there is no evidence that these formulas have good predictive accuracy in pediatric, whose eyes are still undergoing rapid growth and refractive changes. This study is intended to compare the prediction error and the accuracy of predictability of intraocular lens power calculation in pediatric patients at 3 month post cataract surgery with primary implantation of an intraocular lens using SRK II versus Pediatric IOL Calculator for pediatric intraocular lens calculation. Pediatric IOL Calculator is a modification of SRK II using Holladay algorithm. This program attempts to predict the refraction of a pseudophakic child as he grows, using a Holladay algorithm model. This model is based on refraction measurements of pediatric aphakic eyes. Pediatric IOL Calculator uses computer software for intraocular lens calculation.
  12. Kashiwagi K, Chono E, Koesters S, Yap PS
    BMC Ophthalmol, 2020 Jun 10;20(1):223.
    PMID: 32522181 DOI: 10.1186/s12886-020-01508-8
    BACKGROUND: Poor persistence with glaucoma therapy can lead to disease progression and subsequent blindness. Persistence with second-line glaucoma combination treatment in a Japanese real-world setting and whether it differed from fixed and unfixed combination drugs was investigated.

    METHODS: This was a retrospective, non-interventional, cohort study using data from a Japanese medical claims database. Patients with glaucoma aged ≥20 years with a first drug claim for glaucoma treatment between 01 July 2005 and 30 October 2014 and with data for > 6 months before and after this first prescription were included. The primary endpoint was duration of drug persistence among glaucoma patients with and without the use of fixed combination drugs in the year following initiation of second-line combination treatment.

    RESULTS: Of 1403 patients included in the analysis, 364 (25.94%) received fixed combination drugs and 1039 (74.06%) received unfixed combination drugs as second-line treatment. Baseline characteristics were generally comparable between the groups. A total of 39.01% of patients on fixed combination drugs, compared with 41.67% of patients on unfixed combination drugs, persisted on their glaucoma drugs 12 months post second-index date. Median persistence durations for the fixed combination drugs and unfixed combination drugs groups were 6 (95% confidence interval [CI]: 5-8) and 7 months (95% CI 6-9), respectively. Patients who received prostaglandin analogs (PGAs) were the most persistent with their treatment (n = 99, 12.84%). Patients diagnosed with primary open-angle glaucoma were less likely to experience treatment modification (hazard ratio [HR]: 0.800, 95% CI 0.649-0.986, P = 0.036), while those diagnosed with secondary glaucoma were more likely to experience treatment modification (HR: 1.678, 95% CI 1.231-2.288, P = 0.001) compared with glaucoma suspects.

    CONCLUSIONS: In this retrospective claims database study, the persistence rate of second-line glaucoma combination treatment was low, with no difference in persistence between glaucoma patients receiving unfixed combination drugs compared with fixed combination drugs. Patients on PGA showed greater persistence rates compared with other treatments.

  13. Lim CW, Cheng J, Tay ELT, Teo HY, Wong EPY, Yong VKY, et al.
    BMC Ophthalmol, 2018 Dec 10;18(1):315.
    PMID: 30526537 DOI: 10.1186/s12886-018-0976-y
    BACKGROUND: Despite the potential usefulness of optical coherence tomography angiography in retinal and optic disc conditions, the reliability of the imaging modality remains unclear. This study set out to measure the microvascular density of macula and optic disc by mean of optical coherence tomography angiography and report the repeatability of the vessel density measurements.

    METHODS: Cross sectional observational cohort study. Subjects with normal eyes were recruited. Two sets of optical coherence tomography angiography images of macula and optic nerve head were acquired during one visit. Novel in-house developed software was used to count the pixels in each images and to compute the microvessel density of the macula and optic disc. Data were analysed to determine the measurement repeatability.

    RESULTS: A total of 176 eyes from 88 consecutive normal subjects were recruited. For macular images, the mean vessel density at superficial retina, deep retina, outer retina and choriocapillaries segment was OD 0.113 and OS 0.111, OD 0.239 and OS 0.230, OD 0.179 and OS 0.164, OD 0.237 and OS 0.215 respectively. For optic disc images, mean vessel density at vitreoretinal interface, radial peripapillary capillary, superficial nerve head and disc segment at the level of choroid were OD 0.084 and OS 0.085, OD 0.140 and OS 0.138, OD 0.216 and OS 0.209, OD 0.227 and OS 0.236 respectively. The measurement repeatability tests showed that the coefficient of variation of macular scans, for right and left eyes, ranged from 6.4 to 31.1% and 5.3 to 59.4%. Likewise, the coefficient of variation of optic disc scans, for right and left eyes, ranged from 14.3 to 77.4% and 13.5 to 75.3%.

    CONCLUSIONS: Optical coherence tomography angiography is a useful modality to visualise the microvasculature plexus of macula and optic nerve head. The vessel density measurement of macular scan by mean of optical coherence tomography angiography demonstrated good repeatability. The optic disc scan, on the other hand, showed a higher coefficient of variation indicating a lower measurement repeatability than macular scan. Interpretation of optical coherence tomography angiography should take into account test-retest repeatability of the imaging system.

    TRIAL REGISTRATION: National Healthcare Group Domain Specific Review Board ( NHG DSRB ) Singapore. DSRB Reference: 2015/00301.

  14. Loon NW, Gendeh BS, Zakaria R, Hamzah JC, Din NM
    BMC Ophthalmol, 2017 Jun 15;17(1):92.
    PMID: 28619056 DOI: 10.1186/s12886-017-0490-7
    BACKGROUND: Embozene® is a new neuroembolizing microsphere used to reduce intraoperative bleeding for head and neck tumours. We report a case of iatrogenic ophthalmic artery occlusion after Embozene® embolization of the external carotid artery (ECA).

    CASE PRESENTATION: A 22-year-old African gentleman presented with left nasal obstruction and epistaxis for 2 years and was diagnosed with nasopharyngeal carcinoma. He subsequently underwent embolization of the maxillary branch of the left ECA using Embozene® Microspheres - 250 μm in size before endoscopic tumour excision to reduce intra-operative bleeding. He complained of sudden painless profound visual loss in the left eye (LE) two hours after embolization. Visual acuity in LE was no light perception. Fundus examination showed pale retina with no cherry red spot. Arterial narrowing and segmentation were seen in all quadrants. A diagnosis of left ophthalmic artery occlusion was made. Despite immediate management including ocular massage and lowering of intraocular pressure, the visual loss remained. Retrospective review of digital subtraction angiogram showed an anastomosis between the left ophthalmic artery and anterior deep temporal artery as a potential route for microspheres migration.

    CONCLUSION: Pre-operative angio-architecture understanding and diligent selection of embolic material are helpful in preventing this adverse event. The use of newer agents for embolotherapy may cause migration of embolic material from the external to the internal carotid system leading to ophthalmic artery occlusion and blindness.

  15. Samsudin A, Isaacs N, Tai ML, Ramli N, Mimiwati Z, Choo MM
    BMC Ophthalmol, 2016;16:39.
    PMID: 27079202 DOI: 10.1186/s12886-016-0215-3
    Vascular insufficiency has been reported to be a cause of normal tension glaucoma (NTG). The aim of this study was to compare ocular perfusion pressure (OPP) and ophthalmic artery flow (OAF) between patients with NTG and those without glaucoma.
  16. Teow Kheng Leong K, Abu Kassim SNA, Sidhu JK, Zohari Z, Sivalingam T, Ramasamy S, et al.
    BMC Ophthalmol, 2021 Mar 09;21(1):128.
    PMID: 33750348 DOI: 10.1186/s12886-021-01882-x
    BACKGROUND: The current practice for new-born eye examination by an Ophthalmologist in Malaysian hospitals is limited to only preterm new-borns, syndromic or ill infants. Healthy term new-borns are usually discharged without a thorough eye examination. This study is aimed at determining the proportion and types of ocular abnormalities detected in purportedly healthy term new-borns.

    METHOD: This cross-sectional study is comprised of 203 participants, all purportedly healthy term new-born infants from the Obstetrics and Gynaecology ward at Hospital Kuala Lumpur over a 6 months period. The examination list includes external eye examination, red reflex test, and fundus imaging using a wide-field digital retinal imaging system (Phoenix Clinical ICON Paediatric Retinal Camera) by a trained Investigator. The pathologies detected were documented. The results were compared and correlated with similar studies published in the literature previously.

    RESULTS: Total ocular abnormalities were detected in 34% of the infants. The most common finding was retinal haemorrhage in 29.6% of the infants, of which 53.3% occurred bilaterally. Spontaneous vaginal delivery (SVD) remained the greatest risk factor which has nearly 3.5 times higher risk of new-borns developing retinal haemorrhage compared to Lower Segment Caesarean Section (LSCS). There was a 6% increased likelihood of developing retinal haemorrhage for every 1-min increment in the duration of 2nd stage of labour.

    CONCLUSION: Universal eye screening for all new-borns using a wide-field digital imaging system is realistically possible, safe, and useful in detecting posterior segment disorders. The most common abnormality detected is retinal haemorrhage.

  17. Nga AD, Yap SL, Samsudin A, Abdul-Rahman PS, Hashim OH, Mimiwati Z
    BMC Ophthalmol, 2014;14:33.
    PMID: 24655889 DOI: 10.1186/1471-2415-14-33
    Altered levels of specific matrix metalloproteinases (MMPs) and tissue inhibitors of metalloproteinases (TIMPs) in the aqueous humour of primary open-angle glaucoma (POAG) eyes have been described. In this study, levels of specific MMPs and TIMPs in the aqueous humour of primary angle-closure glaucoma (PACG) eyes were measured and compared with those of POAG as well as non-glaucoma control eyes.
  18. Norlaili M, Bakiah S, Zunaina E
    BMC Ophthalmol, 2011;11:36.
    PMID: 22111945 DOI: 10.1186/1471-2415-11-36
    BACKGROUND: Diabetic macular oedema is the leading causes of blindness. Laser photocoagulation reduces the risk of visual loss. However recurrences are common and despite laser treatment, patients with diabetic macular oedema experienced progressive loss of vision. Stabilization of the blood retinal barrier introduces a rationale for intravitreal triamcinolone treatment in diabetic macular oedema. This study is intended to compare the best corrected visual acuity (BCVA) and the macular oedema index (MEI) at 3 month of primary treatment for diabetic macular oedema between intravitreal triamcinolone acetonide (IVTA) and laser photocoagulation.
    METHODS: This comparative pilot study consists of 40 diabetic patients with diabetic macular oedema. The patients were randomized into two groups using envelope technique sampling procedure. Treatment for diabetic macular oedema was based on the printed envelope technique selected for every patient. Twenty patients were assigned for IVTA group (one injection of IVTA) and another 20 patients for LASER group (one laser session). Main outcome measures were mean BCVA and mean MEI at three months post treatment. The MEI was quantified using Heidelberg Retinal Tomography II.
    RESULTS: The mean difference for BCVA at baseline [IVTA: 0.935 (0.223), LASER: 0.795 (0.315)] and at three months post treatment [IVTA: 0.405 (0.224), LASER: 0.525 (0.289)] between IVTA and LASER group was not statistically significant (p = 0.113 and p = 0.151 respectively). The mean difference for MEI at baseline [IVTA: 2.539 (0.914), LASER: 2.139 (0.577)] and at three months post treatment [IVTA: 1.753 (0.614), LASER: 1.711 (0.472)] between IVTA and LASER group was also not statistically significant (p = 0.106 and p = 0.811 respectively).
    CONCLUSIONS: IVTA demonstrates good outcome comparable to laser photocoagulation as a primary treatment for diabetic macular oedema at three months post treatment.
    TRIAL REGISTRATION: ISRCTN05040192 (http://www.controlled-trial.com).
  19. Yusoff M, Alwi AA, Said MM, Zakariah S, Ghani ZA, Zunaina E
    BMC Ophthalmol, 2011;11:15.
    PMID: 21679403 DOI: 10.1186/1471-2415-11-15
    Live intraocular nematode is a rare occurrence. Nematode can migrate actively within the eye, creating visual symptoms and damaging ocular tissue.
  20. Chen X, Zhao Y, Zhang A, Zhou Y, Li M, Cheng X, et al.
    BMC Ophthalmol, 2024 Apr 25;24(1):195.
    PMID: 38664615 DOI: 10.1186/s12886-024-03464-z
    BACKGROUND: Analyzing the glaucoma burden in "Belt and Road" (B&R) countries based on age, gender, and risk factors from 1990 to 2019 in order to provide evidence for future prevention strategies.

    METHODS: We applied global burden of disease(GBD) 2019 to compare glaucoma prevalence and Years lived with disabilities (YLDs) from 1990 to 2019 in the B&R countries. Trends of disease burden between 1990 and 2019 were evaluated using the average annual percent change and the 95% uncertainty interval (UI) were reported.

    RESULTS: From 1990 to 2019, most B&R countries showed a downward trend in age-standardized prevalence and YLDs (all P  85 years), Malaysia(75-84 years), Brunei Darussalam(45-49 years), Afghanistan(70-79 years). Finally, in all Central Asian countries, the age-standardized YLDs due to glaucoma caused by fasting hyperglycemia demonstrated have an increase between 1990 and 2019 (all P 

Related Terms
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links