METHODS: This was a cross-sectional observational study. From 2013 to 2014, we recruited inhabitants aged 50 years or older in Guangzhou, China. Among 1,117 participants in the study, data from 1,015 phakic right eyes were used for analyses. Ocular parameters including axial length (AL), anterior chamber depth (ACD), and corneal curvature (K) were measured using an IOL Master.
RESULTS: The mean AL, ACD, and K were 23.48 mm [95 % confidence interval (CI), 23.40-23.55], 3.03 mm (CI, 3.01-3.05), and 44.20 mm (CI, 44.11-44.29), respectively. A mean reduction in ACD with age was observed (P = 0.002) in male subjects but not in female subjects (P = 0.558). Male subjects had significantly longer ALs (23.68 mm versus 23.23 mm, P
METHODS: Cross sectional observational cohort study. Subjects with normal eyes were recruited. Two sets of optical coherence tomography angiography images of macula and optic nerve head were acquired during one visit. Novel in-house developed software was used to count the pixels in each images and to compute the microvessel density of the macula and optic disc. Data were analysed to determine the measurement repeatability.
RESULTS: A total of 176 eyes from 88 consecutive normal subjects were recruited. For macular images, the mean vessel density at superficial retina, deep retina, outer retina and choriocapillaries segment was OD 0.113 and OS 0.111, OD 0.239 and OS 0.230, OD 0.179 and OS 0.164, OD 0.237 and OS 0.215 respectively. For optic disc images, mean vessel density at vitreoretinal interface, radial peripapillary capillary, superficial nerve head and disc segment at the level of choroid were OD 0.084 and OS 0.085, OD 0.140 and OS 0.138, OD 0.216 and OS 0.209, OD 0.227 and OS 0.236 respectively. The measurement repeatability tests showed that the coefficient of variation of macular scans, for right and left eyes, ranged from 6.4 to 31.1% and 5.3 to 59.4%. Likewise, the coefficient of variation of optic disc scans, for right and left eyes, ranged from 14.3 to 77.4% and 13.5 to 75.3%.
CONCLUSIONS: Optical coherence tomography angiography is a useful modality to visualise the microvasculature plexus of macula and optic nerve head. The vessel density measurement of macular scan by mean of optical coherence tomography angiography demonstrated good repeatability. The optic disc scan, on the other hand, showed a higher coefficient of variation indicating a lower measurement repeatability than macular scan. Interpretation of optical coherence tomography angiography should take into account test-retest repeatability of the imaging system.
TRIAL REGISTRATION: National Healthcare Group Domain Specific Review Board ( NHG DSRB ) Singapore. DSRB Reference: 2015/00301.
METHODS: This was a retrospective, non-interventional, cohort study using data from a Japanese medical claims database. Patients with glaucoma aged ≥20 years with a first drug claim for glaucoma treatment between 01 July 2005 and 30 October 2014 and with data for > 6 months before and after this first prescription were included. The primary endpoint was duration of drug persistence among glaucoma patients with and without the use of fixed combination drugs in the year following initiation of second-line combination treatment.
RESULTS: Of 1403 patients included in the analysis, 364 (25.94%) received fixed combination drugs and 1039 (74.06%) received unfixed combination drugs as second-line treatment. Baseline characteristics were generally comparable between the groups. A total of 39.01% of patients on fixed combination drugs, compared with 41.67% of patients on unfixed combination drugs, persisted on their glaucoma drugs 12 months post second-index date. Median persistence durations for the fixed combination drugs and unfixed combination drugs groups were 6 (95% confidence interval [CI]: 5-8) and 7 months (95% CI 6-9), respectively. Patients who received prostaglandin analogs (PGAs) were the most persistent with their treatment (n = 99, 12.84%). Patients diagnosed with primary open-angle glaucoma were less likely to experience treatment modification (hazard ratio [HR]: 0.800, 95% CI 0.649-0.986, P = 0.036), while those diagnosed with secondary glaucoma were more likely to experience treatment modification (HR: 1.678, 95% CI 1.231-2.288, P = 0.001) compared with glaucoma suspects.
CONCLUSIONS: In this retrospective claims database study, the persistence rate of second-line glaucoma combination treatment was low, with no difference in persistence between glaucoma patients receiving unfixed combination drugs compared with fixed combination drugs. Patients on PGA showed greater persistence rates compared with other treatments.
METHODS: A cross-sectional observational study was performed on healthy and glaucoma subjects, on whom two sets of OCTA images of optic disc and macula were acquired using both AngioVue (Optovue, USA) and Swept Source (Topcon, Japan) OCTA devices during one visit. A novel in-house software was used to calculate the vessel densities. Diagnostic accuracy of the machines in differentiating healthy versus glaucomatous eyes was determined using area under the receiver operating characteristic curve (AUROC) and test-retest repeatability of the machines was also evaluated.
RESULTS: A total of 80 healthy and 38 glaucomatous eyes were evaluated. Glaucomatous eyes had reduced mean vessel density compared to healthy controls in all segmented layers of the optic disc and macula using AngioVue (p ≤ 0.001). However, glaucomatous eyes had higher mean vessel density on optic disc scans using Swept Source, with lack of statistically significant difference between healthy and glaucomatous eyes. The AUROC showed better diagnostic accuracy of AngioVue (0.761-1.000) compared to Swept Source (0.113-0.644). The test-retest reliability indices were generally better using AngioVue than Swept Source.
CONCLUSIONS: AngioVue showed better diagnostic capability and test-retest reliability compared to Swept Source. Further studies need to be undertaken to evaluate if there is any significant difference between the various machines in diagnosing and monitoring glaucoma.
CASE PRESENTATION: A 67-year old male presented with left Cogan's anterior internuclear ophthalmoplegia (INO), left appendicular ataxia and bilateral upgaze palsy. A Magnetic Resonance Imaging (MRI) and Magnetic Resonance Angiography (MRA) brain showed a left dorsal tegmental infarct at the level of pontomesencephalic junction.
CONCLUSIONS: This case highlights the clinical importance of Cogan's anterior INO in combination with upgaze palsy and ataxia, and report possible site of lesion in patients with such constellation. Clinicians should consider looking for cerebellar signs in cases of Cogan's anterior INO, apart from just considering localizing the lesion at the midbrain.
METHODS: Retrospective case series of patients presenting to Westmead Hospital, Sydney, Australia with open globe injuries from 1st January 2005 to 31st December 2017. Data collected included demographic information, ocular injury details, management and initial and final visual acuities.
RESULTS: A total of 104 cases were identified. Predictors of poor final visual outcomes included poor presenting visual acuity (p
METHOD: This cross-sectional study is comprised of 203 participants, all purportedly healthy term new-born infants from the Obstetrics and Gynaecology ward at Hospital Kuala Lumpur over a 6 months period. The examination list includes external eye examination, red reflex test, and fundus imaging using a wide-field digital retinal imaging system (Phoenix Clinical ICON Paediatric Retinal Camera) by a trained Investigator. The pathologies detected were documented. The results were compared and correlated with similar studies published in the literature previously.
RESULTS: Total ocular abnormalities were detected in 34% of the infants. The most common finding was retinal haemorrhage in 29.6% of the infants, of which 53.3% occurred bilaterally. Spontaneous vaginal delivery (SVD) remained the greatest risk factor which has nearly 3.5 times higher risk of new-borns developing retinal haemorrhage compared to Lower Segment Caesarean Section (LSCS). There was a 6% increased likelihood of developing retinal haemorrhage for every 1-min increment in the duration of 2nd stage of labour.
CONCLUSION: Universal eye screening for all new-borns using a wide-field digital imaging system is realistically possible, safe, and useful in detecting posterior segment disorders. The most common abnormality detected is retinal haemorrhage.
METHODS: The Malay version was translated by two independent translators who were well versed in both languages. We carried out a cross-sectional study collecting data between June 2017 and March 2018 in the pre-operative Eye Clinic of Hospital Melaka with 224 respondents (mean age 66.8 years) and another 204 respondents (mean age 64.3 years) participating in the English version and Malay version of the Questionnaire respectively. Methods used to validate the standard questionnaire included the use of construct validity via factor analysis and the deployment of reliability test through assessment of internal consistency via Cronbach's alpha.
RESULTS: We observed both English and Bahasa Malaysia versions to have high reliability with Cronbach's alpha values of 0.90 and above in factors on difficulty with activities and responses to vision problems. Exploratory factor analysis performed revealed that the three-factor model fits the data well for the English version of the questionnaire - difficulty with activities (23.81 % of variance), responses to vision problem (22.22 % of variance) and general health and vision (14.68 % of variance). The Bahasa Malaysia version of the questionnaire produced three factors with two of the factors resembling the factors from the original version of the questionnaire - difficulty with activities (24.3 % of variance) and responses to vision problem (23.7 % of variance). Item response theory analysis revealed that these factors for both English and Bahasa Malaysia versions comprised of adequately fitted items.
CONCLUSION: The present study observed that both the English and Bahasa Malaysia versions of the NEI VFQ-25 have comparable construct validity to the original American version. With high validity and reliability, the tool shall be able to provide health care providers the assessment of impact due to cataract and other ophthalmic conditions on the vision-related quality of life of ophthalmic patients.