  1. Dharmendran R, Zainal AA
    Med J Malaysia, 2003 Mar;58(1):135-8.
    PMID: 14556341
    This is a case report of an elderly male, who presented with duodenal obstruction caused by abdominal aortic aneurysm. An axillo-bifemoral shunting with an infra renal straight inlay graft together with a feeding jejunostomy was performed. This is rare presentation with only a few cases reported.
    Matched MeSH terms: Aortic Aneurysm, Abdominal/complications*
  2. Goh ZNL, Seak JC, Seak CK, Wu CT, Seak CJ
    Medicine (Baltimore), 2019 Aug;98(31):e16645.
    PMID: 31374036 DOI: 10.1097/MD.0000000000016645
    RATIONALE: Abdominal aortic aneurysm is an extremely rare cause of deep vein thrombosis. Here we report an elderly gentleman who presented with deep vein thrombosis and was found to have concomitant abdominal aortic aneurysm upon ultrasonographic screening. It illustrates the possibility of such an aetiology, and the importance of screening for such aneurysms in a select patient population before heparinization.

    PATIENT CONCERNS: A 73-year-old Asian gentleman with underlying hypertension, hyperlipidaemia, chronic renal failure, and history of chronic smoking presented to the emergency department with acute left lower limb swelling of 1 day. On examination, the patient was tachycardic (110 beats/minute) and hypertensive (168/84 millimeters mercury (mmHg)). The entire left lower limb was swollen with notable pitting oedema, tenderness, and warmth; left calf swelling was measured to be 4 centimeters (cm).

    DIAGNOSES: The patient's Wells score of 4 placed him in the high-risk group for deep vein thrombosis. Serum D-dimer was subsequently found to be elevated at 926 nanograms/milliliter (ng/ml). Compression ultrasonography revealed a thrombus in the left deep femoral vein, confirming the diagnosis of deep vein thrombosis. The ultrasonographic evaluation was extended to the abdominal aorta due to the patient's high risk of abdominal aortic aneurysm, and a 7-cm aneurysm was indeed found. Further computed tomography and magnetic resonance imaging localized it to the infrarenal region, with left common iliac vein compression resulting in stagnant venous return.

    INTERVENTIONS: Emergency endovascular repair was performed with insertion of an inferior vena cava filter.

    OUTCOMES: The patient was subsequently monitored in the intensive care unit and uneventfully discharged after 2 weeks.

    LESSONS: Such clinical presentations of deep vein thrombosis are rare, but physicians are reminded to consider screening for abdominal aneurysms and other anatomical causes before heparinization in patients who seemingly do not have thromboembolic risk factors. This is especially so for the high risk group of male deep vein thrombosis patients aged 65-75 years with a history of smoking who have yet to be screened for abdominal aortic aneurysms, in line with United States Preventive Services Task Force recommendations.

    Matched MeSH terms: Aortic Aneurysm, Abdominal/complications*
  3. Teoh MK, Ramasamy D, Wong KP
    Aust N Z J Surg, 1992 Nov;62(11):862-5.
    PMID: 20169704
    Ultrasound examination of the abdominal aorta was performed on 100 patients with cardiovascular disease and a control group of 100 subjects. The objectives were to define the normal aortic size of Malaysians, to screen for aneurysms and to compare the aorta size of the different population groups. In the study group the mean anteroposterior (AP) diameter of the non-aneurysmal aortas at the level of the renal arteries was 1.82 cm (range 0.9-2.6 cm) in men and 1.83 cm (range 1.5-2.3 cm) in women. This compares with 1.61 cm (range 1.1-2.2 cm) in men and 1.50 cm (range 0.8-2.4 cm) in women in the control group. The dimensions of the infrarenal aorta show a similar relationship between the two groups. These AP diameters were significantly smaller than the published figures from studies done on Western populations and are consistent with the smaller stature of Malaysians. Five aneurysms and one ectasia were found (mean size 5 cm, range 3.5-6.0 cm), all in men aged 50-75 years in the study group, and none in the control group. All the aneurysms were easily palpable in these patients who were thinner than the average Caucasian. Given the lower incidence of aortic aneurysms in Malaysians there is no role for routine ultrasound screening of the population. High risk groups can be adequately screened by clinical examination alone.
    Matched MeSH terms: Aortic Aneurysm, Abdominal/complications