  1. Lai NM, Lai NA, O'Riordan E, Chaiyakunapruk N, Taylor JE, Tan K
    Cochrane Database Syst Rev, 2016 Jul 13;7:CD010140.
    PMID: 27410189 DOI: 10.1002/14651858.CD010140.pub2
    BACKGROUND: The central venous catheter (CVC) is a device used for many functions, including monitoring haemodynamic indicators and administering intravenous medications, fluids, blood products and parenteral nutrition. However, as a foreign object, it is susceptible to colonisation by micro-organisms, which may lead to catheter-related blood stream infection (BSI) and in turn, increased mortality, morbidities and health care costs.

    OBJECTIVES: To assess the effects of skin antisepsis as part of CVC care for reducing catheter-related BSIs, catheter colonisation, and patient mortality and morbidities.

    SEARCH METHODS: In May 2016 we searched: The Cochrane Wounds Specialised Register; The Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library); Ovid MEDLINE (including In-Process & Other Non-Indexed Citations and Epub Ahead of Print); Ovid EMBASE and EBSCO CINAHL Plus. We also searched clinical trial registries for ongoing and unpublished studies. There were no restrictions with respect to language, date of publication or study setting.

    SELECTION CRITERIA: We included randomised controlled trials (RCTs) that assessed any type of skin antiseptic agent used either alone or in combination, compared with one or more other skin antiseptic agent(s), placebo or no skin antisepsis in patients with a CVC in place.

    DATA COLLECTION AND ANALYSIS: Two authors independently assessed the studies for their eligibility, extracted data and assessed risk of bias. We expressed our results in terms of risk ratio (RR), absolute risk reduction (ARR) and number need to treat for an additional beneficial outcome (NNTB) for dichotomous data, and mean difference (MD) for continuous data, with 95% confidence intervals (CIs).

    MAIN RESULTS: Thirteen studies were eligible for inclusion, but only 12 studies contributed data, with a total of 3446 CVCs assessed. The total number of participants enrolled was unclear as some studies did not provide such information. The participants were mainly adults admitted to intensive care units, haematology oncology units or general wards. Most studies assessed skin antisepsis prior to insertion and regularly thereafter during the in-dwelling period of the CVC, ranging from every 24 h to every 72 h. The methodological quality of the included studies was mixed due to wide variation in their risk of bias. Most trials did not adequately blind the participants or personnel, and four of the 12 studies had a high risk of bias for incomplete outcome data.Three studies compared different antisepsis regimens with no antisepsis. There was no clear evidence of a difference in all outcomes examined, including catheter-related BSI, septicaemia, catheter colonisation and number of patients who required systemic antibiotics for any of the three comparisons involving three different antisepsis regimens (aqueous povidone-iodine, aqueous chlorhexidine and alcohol compared with no skin antisepsis). However, there were great uncertainties in all estimates due to underpowered analyses and the overall very low quality of evidence presented.There were multiple head-to-head comparisons between different skin antiseptic agents, with different combinations of active substance and base solutions. The most frequent comparison was chlorhexidine solution versus povidone-iodine solution (any base). There was very low quality evidence (downgraded for risk of bias and imprecision) that chlorhexidine may reduce catheter-related BSI compared with povidone-iodine (RR of 0.64, 95% CI 0.41 to 0.99; ARR 2.30%, 95% CI 0.06 to 3.70%). This evidence came from four studies involving 1436 catheters. None of the individual subgroup comparisons of aqueous chlorhexidine versus aqueous povidone-iodine, alcoholic chlorhexidine versus aqueous povidone-iodine and alcoholic chlorhexidine versus alcoholic povidone-iodine showed clear differences for catheter-related BSI or mortality (and were generally underpowered). Mortality was only reported in a single study.There was very low quality evidence that skin antisepsis with chlorhexidine may also reduce catheter colonisation relative to povidone-iodine (RR of 0.68, 95% CI 0.56 to 0.84; ARR 8%, 95% CI 3% to 12%; ; five studies, 1533 catheters, downgraded for risk of bias, indirectness and inconsistency).Evaluations of other skin antiseptic agents were generally in single, small studies, many of which did not report the primary outcome of catheter-related BSI. Trials also poorly reported other outcomes, such as skin infections and adverse events.

    AUTHORS' CONCLUSIONS: It is not clear whether cleaning the skin around CVC insertion sites with antiseptic reduces catheter related blood stream infection compared with no skin cleansing. Skin cleansing with chlorhexidine solution may reduce rates of CRBSI and catheter colonisation compared with cleaning with povidone iodine. These results are based on very low quality evidence, which means the true effects may be very different. Moreover these results may be influenced by the nature of the antiseptic solution (i.e. aqueous or alcohol-based). Further RCTs are needed to assess the effectiveness and safety of different skin antisepsis regimens in CVC care; these should measure and report critical clinical outcomes such as sepsis, catheter-related BSI and mortality.

    Matched MeSH terms: Central Venous Catheters/microbiology
  2. Tiwari S, Sahu M, Rautaraya B, Karuna T, Mishra SR, Bhattacharya S
    J Indian Med Assoc, 2011 Nov;109(11):800-1.
    PMID: 22666934
    Methicillin-resistant Staphylococcus aureus (MRSA) emerged as a nosocomial pathogen in early 1960s, causing Increasing number of outbreaks in 19708, first reported in a teaching hospital in Malaysia in 1972, causing increased mortality, morbidity, and healthcare costs. Aim of this study is to screen out MRSA from various clinical samples and to see their antibiotic susceptibility pattern. From May 2008 to May 2009, 204 S aureus strains were isolated, out of which 114 (55.8%) were MRSA, and rest methicillin-sensitive Staphylococcus aureus (MSSA). Most of the MRSA strains were obtained from pus (45%) followed by urine (20.5%). Frequency of isolating MRSA were maximum in catheter tip (80%) followed by blood (66.7%) and pus (58.7%). MRSA strains were showing 100% sensitivity to vancomycin and Iinezolid, whereas 92.9% to teicoplanin. Therefore it is concluded that antibiotics other than vancomycin can be used as anti-MRSA agents after sensitivity test, as well as irrational and indiscriminate use of antibiotics can be avoided.
    Matched MeSH terms: Catheters/microbiology
  3. Chung PY
    FEMS Microbiol Lett, 2016 10;363(20).
    PMID: 27664057
    Klebsiella pneumoniae is an opportunistic pathogen that commonly causes nosocomial infections in the urinary tract, respiratory tract, lung, wound sites and blood in individuals with debilitating diseases. Klebsiella pneumoniae is still a cause of severe pneumonia in alcoholics in Africa and Asia, and the predominant primary pathogen of primary liver abscess in Taiwan and Southeast Asia, particularly in Asian and Hispanic patients, and individuals with diabetes mellitus. In the United States and Europe, K. pneumoniae infections are most frequently associated with nosocomial infections. The emergence of antibiotic-resistant strains of K. pneumoniae worldwide has become a cause of concern where extended-spectrum β-lactamases (ESBLs) and carbapenemase-producing strains have been isolated with increasing frequency. The pathogen's ability to form biofilms on inserted devices such as urinary catheter has been proposed as one of the important mechanisms in nosocomially acquired and persistent infections, adding to the increased resistance to currently used antibiotics. In this review, infections caused by K. pneumoniae, antibiotic resistance and formation of biofilm will be discussed.
    Matched MeSH terms: Urinary Catheters/microbiology
  4. Jassim SA, Abdulamir AS, Abu Bakar F
    World J Microbiol Biotechnol, 2012 Jan;28(1):47-60.
    PMID: 22806779 DOI: 10.1007/s11274-011-0791-6
    To explore new approaches of phage-based bio-process of specifically pathogenic Escherichia coli bacteria in food products within a short period. One hundred and forty highly lytic designed coliphages were used. Escherichia coli naturally contaminated and Enterohemorrhagic Escherichia coli experimentally inoculated samples of lettuce, cabbage, meat, and egg were used. In addition, experimentally produced biofilms of E. coli were tested. A phage concentration of 10(3) PFU/ml was used for food products immersion, and for spraying of food products, 10(5) PFU/ml of a phage cocktail was used by applying a 20-s optimal dipping time in a phage cocktail. Food samples were cut into pieces and were either sprayed with or held in a bag immersed in lambda buffer containing a cocktail of 140 phages. Phage bio-processing was successful in eliminating completely E. coli in all processed samples after 48 h storage at 4°C. Partial elimination of E. coli was observed in earlier storage periods (7 and 18 h) at 24° and 37°C. Moreover, E. coli biofilms were reduced >3 log cycles upon using the current phage bio-processing. The use of a phage cocktail of 140 highly lytic designed phages proved highly effective in suppressing E. coli contaminating food products. Proper decontamination/prevention methods of pathogenic E. coli achieved in this study can replace the current chemically less effective decontamination methods.
    Matched MeSH terms: Urinary Catheters/microbiology