Displaying all 3 publications

Abstract:
Sort:
  1. Tan WJ, Kwan MK, Deepak AS, Saw A, Peng BC, Jalalullah W
    Med J Malaysia, 2006 Dec;61 Suppl B:18-22.
    PMID: 17600988
    Fracture of the femur is most commonly treated with interlocking nailing. We conducted this study to describe and analyze the size of femoral interlocking nails used in our local population. This is a retrospective study on reamed intramedullary interlocking nailing procedures performed between 1st July 1998 and 30th June 2003. Demographic data, the diameter and length of femoral nails used were obtained from patient's medical record. A total of 267 procedures were included. The most common diameter used was 10 mm (56.9%), followed by 11 mm (27.0%) and 12 mm (13.1%). Only 2.6% of the nails were less than 10 mm in diameter. The most common nail length was 38 cm (31.1%), followed by 36 cm (24.9%) and 40 cm (19.5%). The longest nail used was 46 cm while the shortest 32 cm. The most commonly used femoral nails were of 10 mm diameter with the length ranging from 36 to 40 cm, which is smaller than those reported in the English literature. Nails with diameter smaller than 10 mm were required in 2.6% of patients.
    Matched MeSH terms: Diaphyses/injuries*
  2. Zainudin M, Razak M, Shukur SH
    Med J Malaysia, 2000 Sep;55 Suppl C:59-67.
    PMID: 11200046
    We present the results of our experience in treating comminuted tibial shaft fractures with reamed interlocking intramedullary nail from September 1993 to December 1995. In this retrospective study, there were fifty patients with an average follow-up of 14.3 months (range six to twenty-eight months). Ninety-eight percent of the fractures were due to motor-vehicle accident with majority of the patients being motorcyclist (96%). Thirty-eight fractures were closed and twelve were open (Gustilo grade I--8; grade II--4); 44% of them had additional fractures or other injuries. According to Winquist-Hansen classification of diaphyseal fracture comminution, there were 24% type I; 18% type II; 26% type III and 32% type IV. The union rate was 98%. There were 6 infections, 2 superficial and 4 deep. All these infections arose from closed fractures, which was possibly due to the long operative time. No patients with open fractures, which underwent delayed nailing, had infection. One of the patient had severe deep infection which required early nail removal before union. Anterior knee pain following nailing occurred in 6% of the patients. The average hospital stay after operation was 3.4 days. Ninety-four percent of the patients had excellent to good functional outcome after nailing. The mean time to regain full range of movement of knee and ankle was 8.4 weeks. Patients were allowed full weight bearing in the average time of 10.7 weeks and the mean time to return to work was 24.7 weeks.
    Matched MeSH terms: Diaphyses/injuries*
  3. Ling HT, Kwan MK, Chua YP, Deepak AS, Ahmad TS
    Med J Malaysia, 2006 Dec;61 Suppl B:8-12.
    PMID: 17600986
    Treatment of radius or ulna nonunion requires both osteogenic environment and mechanical stability. We would like to report three radial and six ulnar diaphyseal nonunions treated with 3.5 mm locking compression plate (LCP) fixation. To assess the effectiveness of 3.5 mm LCP in treating diaphyseal nonunion of the forearm bones, we prospectively reviewed nine patients with the mean age of 33 years with diaphyseal nonunion of the radius or ulna. All patients were treated with 3.5 mm LCP. Bone grafting was only performed for atrophic nonunion. Surgical and functional outcome were evaluated. There were three atrophic nonunion of the radius, four atrophic nonunion of the ulna and two hypertrophic nonunion of the ulna. All nonunion united successfully with satisfactory functional outcome. 3.5 mm LCP is effective in the treatment of nonunion of ulna or radius.
    Matched MeSH terms: Diaphyses/injuries
Related Terms
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links