Displaying all 3 publications

Abstract:
Sort:
  1. Noor Khairiah AK, Mohamad Nazrulhisham MN, Hazman MN
    Med J Malaysia, 2018 12;73(6):407-409.
    PMID: 30647215
    Malignant intrathoracic disease is the commonest cause of superior vena cava (SVC) obstruction. Life threatening SVC obstruction with intense dyspnoea requires urgent treatment. SVC stenting has been developed in recent years which results in rapid relief of the obstruction. The Yconfiguration technique has been reported to provide support for all three limbs of the bifurcation to prevent restenosis. At present, there are limited reports on the use of Y-configuration stent in stent techniques for endovascular stenting in malignant SVC obstruction. We share our clinical experience of two patients who received balloon-mounted stents using this technique.
    Matched MeSH terms: Endovascular Procedures/instrumentation
  2. Promphan W, Han Siang K, Prachasilchai P, Jarutach J, Makonkawkeyoon K, Siwaprapakorn W, et al.
    Catheter Cardiovasc Interv, 2020 09 01;96(3):E310-E316.
    PMID: 32299151 DOI: 10.1002/ccd.28892
    OBJECTIVES: To assess feasibility and early outcomes of using BeGraft Aortic stent in the treatment of aortic coarctation (CoA).

    BACKGROUND: BeGraft Aortic stent (Bentley InnoMed, Hechingen, Germany) allows large postdilation diameter up to 30 mm. With availability of lengths of 19-59 mm and lower stent profile, they can be used in native and recurrent CoA in adults and in pediatric patients.

    MATERIALS AND METHODS: This is a multicentre retrospective analysis of 12 implanted BeGraft Aortic stents in CoA between May 2017 and April 2019.

    RESULTS: Twelve patients aged 7.7-38 years (median 18.3 years) with body weight of 19.9-56 kg (median 45.5 kg). Eight patients (66%) had native juxtaductal CoA while four had recurrent CoA after previous surgical or transcatheter treatments. The stents were implanted successfully in all the patients with no serious adverse events. The length of the stents ranged from 27 to 59 mm and the implanted stent diameter varied from 12 to 18 mm. The median intraprocedural CoA pressure gradient decreased from 25 mmHg (range 16-66 mmHg) to 2 mmHg (range 0-13 mmHg). The mean follow-up duration was 10.2 months. Two patient (16.6%) had residual stent narrowing requiring staged redilation. One patient (8%) had pseudoaneurysm formation at 1 year cardiac CT follow-up.

    CONCLUSIONS: The BeGraft Aortic stent may be considered to be safe and effective in the short term in treatment of CoA from childhood to adulthood. Long-term follow-up is needed.

    Matched MeSH terms: Endovascular Procedures/instrumentation*
  3. Yew KL, Anderson S, Farah R, Lim SH
    Asian Cardiovasc Thorac Ann, 2014 Oct;22(8):979-80.
    PMID: 24887840 DOI: 10.1177/0218492313491583
    Central vein stenosis is not uncommon in hemodialysis-dependent patients as a result of mechanical damage to the vessel walls from prior cannulation. It can cause ipsilateral upper limb swelling and pain, resulting in suboptimal hemodialysis. It is unfortunate for bilateral central vein stenosis to develop concomitantly, and rare in the setting of an in-situ pacemaker. This case illustrates the successful ligation of a nondependent left arteriovenous fistula and stenting of the right subclavian vein with functioning ipsilateral arteriovenous fistula, to overcome the problem of symptomatic bilateral upper limb swelling.
    Matched MeSH terms: Endovascular Procedures/instrumentation