Displaying all 8 publications

Abstract:
Sort:
  1. Pang T
    Med J Malaysia, 1979 Dec;34(2):91-4.
    PMID: 398437
    Matched MeSH terms: Immunologic Techniques*
  2. Syed Azim SM, Muhamad NA, Leong CF, Hussin NH
    Malays J Pathol, 2015 Aug;37(2):109-14.
    PMID: 26277667 MyJurnal
    Antibody screening is important for the antenatal screening and pre-transfusion tests. This study aimed to compare the MUT/Mur kodecytesAbtectcell III (CSL Abtectcell III) red cell antibody screening kit with DiaMed ID-Dia Cell I-II-III Asia that was then used in our laboratory. In this study, 125 samples were randomly chosen, with 67 samples of known antibody specificities and 58 samples identified as negative for antibody, as the negative control. Concordant negative results were obtained in 57 out of 58 antibody negative samples. Concordant antibody positive results with both reagents were seen in 49 out of 67 samples. There were 18 discrepant results of antibody screening with CSL Abtetcell III (16/18 for vMNS antibodies). The sensitivity and specificity for CSL Abtectcell III were 73.0% and 98.3% respectively. In conclusion, the CSL Abtectcell III reagent would be an acceptable alternative for screening of red cell alloantibodies. It was able to detect all the clinically significant alloantibodies.
    Matched MeSH terms: Immunologic Techniques*
  3. Kumarasamy V, Zuridah H, Hani AW, Mariam M, Chua KB
    Med J Malaysia, 2007 Mar;62(1):85-6.
    PMID: 17682584 MyJurnal
    The performance of a commercial rapid immunochromatographic dengue IgG/IgM assay device was evaluated against an in-place dengue IgM-capture ELISA in the National Public Health laboratory. Of the 239 serum samples from patients with clinical diagnosis of acute dengue illness, 140 and 99 samples were tested positive and negative respectively for anti-dengue IgM by the in-placed ELISA. Comparatively, 72 and 76 samples were tested positive and negative respectively, and 91 samples gave equivocal results by the rapid dengue test device. The rapid immunochromatographic assay device gave a relative sensitivity of 49.3% and a relative specificity of 62.6%. Though the rapid immunochromatographic assay device has the advantages of rapid testing which simultaneously detects both IgG and IgM and can also be performed with whole blood, serum or plasma, the user has to exercise extreme caution with the interpretation of the test result.
    Matched MeSH terms: Immunologic Techniques*
  4. Cardosa MJ
    Malays J Pathol, 1989 Aug;11:7-10.
    PMID: 2698983
    Matched MeSH terms: Immunologic Techniques/trends
  5. Lim EJ, Lopez CG, Veera SN, Menaka N, Aminah A
    Malays J Pathol, 1996 Dec;18(2):107-12.
    PMID: 10879231
    Provision of quality care, service and blood products to patients while containing costs and the amount of blood used should be the aim of every blood bank. Therefore a prospective audit was carried out over three months to determine how efficiently blood was being used in elective surgery in the University Hospital, Kuala Lumpur. Every case with blood crossmatched was monitored to determine the amount transfused and the posttransfusion haemoglobin level. Overcrossmatching of varying degrees was noted in almost all surgical procedures and overtransfusion in 45.5% of patients transfused. The rate of case postponement was 18.1%. These indicate inefficient utilization of blood and other resources. The transfusion index (TI) and range of units transfused were calculated for each procedure. They can be used as indicators of blood requirement and potential severity of hemorrhage. Suggestions to improve efficiency of blood utilization include the introduction and ongoing monitoring of guidelines on crossmatching and transfusion based on the data obtained here, by the hospital blood transfusion committee; the "group, screen and hold" practice for surgical procedures with high crossmatch transfusion ratios, low transfusion indices and a small range of units transfused could also be adopted.
    Matched MeSH terms: Immunologic Techniques/utilization
  6. Musalmah M, Normah J, Wan Mohamad WB, Salwah ON, Fatah HA, Nik Zahari NA
    Med J Malaysia, 2000 Sep;55(3):352-6.
    PMID: 11200716
    The effect of HbE, a hemoglobin variant, on the determination of HbA1/HbA1c using 4 commercial kits based on cation-exchange resin, cation-exchange column chromatography and specific antibody techniques was studied. Fifty-eight normal and 63 HbE heterozygous subjects were tested for HbA1 and HbA1c using 4 commercial kits i.e. Eagles Diagnostics, Boehringer Mannehim (BM), Diastat and Ames DCA 2000. Analyses of the samples by the 4 kits were done within one week and samples were stored at 4 degrees C before analysis. The results showed that HbE affects the determination of glycosylated hemoglobin using cation-exchange based and not kits based on specific antibody techniques.
    Matched MeSH terms: Immunologic Techniques
  7. Noruddin NA, Saim AB, Chua KH, Idrus R
    Laryngoscope, 2007 Dec;117(12):2139-45.
    PMID: 17891046
    OBJECTIVE: To compare a co-culture system with a conventional dispase-dissociation method for obtaining functional human respiratory epithelial cells from the nasal turbinates for tissue engineering application.

    METHODS: Human respiratory epithelial cells were serially passaged using a co-culture system and a conventional dispase-dissociation technique. The growth kinetics and gene expression levels of the cultured respiratory epithelial cells were compared. Four genes were investigated, namely cytokeratin-18, a marker for ciliated and secretory epithelial cells; cytokeratin-14, a marker for basal epithelial cells; MKI67, a proliferation marker; and MUC5B, a marker for mucin secretion. Immunocytochemical analysis was performed using monoclonal antibodies against the high molecular-weight cytokeratin 34 beta E12, cytokeratin 18, and MUC5A to investigate the protein expression from cultured respiratory epithelial cells.

    RESULTS: Respiratory epithelial cells cultured using both methods maintained polygonal morphology throughout the passages. At passage 1, co-cultured respiratory epithelial showed a 2.6-times higher growth rate compared to conventional dispase dissociation technique, and 7.8 times higher at passage 2. Better basal gene expression was observed by co-cultured respiratory epithelial cells compared to dispase dissociated cells. Immunocytochemical analyses were positive for the respiratory epithelial cells cultured using both techniques.

    CONCLUSION: Co-culture system produced superior quality of cultured human respiratory epithelial cells from the nasal turbinates as compared to dispase dissociation technique.

    Matched MeSH terms: Immunologic Techniques*
  8. Joseph PG, Hedger RS
    Vet Rec, 1984 May 19;114(20):494-6.
    PMID: 6330961
    In Malaysia, where vaccination campaigns against foot-and-mouth disease and haemorrhagic septicaemia are routinely carried out, it was desirable to determine whether it was safe and efficacious to administer both vaccines simultaneously. A trial group of 104 cattle was divided into three groups; group 1 animals received both vaccines simultaneously, group 2 animals received only foot-and-mouth disease vaccine and group 3 animals received only haemorrhagic septicaemia vaccine. The serological response to vaccinations was monitored at 0, 21 and 35 days by the virus neutralisation test for foot-and-mouth disease and the mouse-protection and indirect haemagglutination tests for haemorrhagic septicaemia. The simultaneous administration of the two inactivated vaccines produced no adverse effects and the serological response did not differ from the response to either vaccine given separately, thus indicating that cattle may be safely and effectively vaccinated simultaneously in this way.
    Matched MeSH terms: Immunologic Techniques
Related Terms
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links