Displaying all 2 publications

Abstract:
Sort:
  1. Al-Saffar Y, Moo EK, Pingguan-Murphy B, Matyas J, Korhonen RK, Herzog W
    Connect Tissue Res, 2023 May;64(3):294-306.
    PMID: 36853960 DOI: 10.1080/03008207.2023.2166500
    Cartilage cracks disrupt tissue mechanics, alter cell mechanobiology, and often trigger tissue degeneration. Yet, some tissue cracks heal spontaneously. A primary factor determining the fate of tissue cracks is the compression-induced mechanics, specifically whether a crack opens or closes when loaded. Crack deformation is thought to be affected by tissue structure, which can be probed by quantitative polarized light microscopy (PLM). It is unclear how the PLM measures are related to deformed crack morphology. Here, we investigated the relationship between PLM-derived cartilage structure and mechanical behavior of tissue cracks by testing if PLM-derived structural measures correlated with crack morphology in mechanically indented cartilages.

    METHODS: Knee joint cartilages harvested from mature and immature animals were used for their distinct collagenous fibrous structure and composition. The cartilages were cut through thickness, indented over the cracked region, and processed histologically. Sample-specific birefringence was quantified as two-dimensional (2D) maps of azimuth and retardance, two measures related to local orientation and degree of alignment of the collagen fibers, respectively. The shape of mechanically indented tissue cracks, measured as depth-dependent crack opening, were compared with azimuth, retardance, or "PLM index," a new parameter derived by combining azimuth and retardance.

    RESULTS: Of the three parameters, only the PLM index consistently correlated with the crack shape in immature and mature tissues.

    CONCLUSION: In conclusion, we identified the relative roles of azimuth and retardance on the deformation of tissue cracks, with azimuth playing the dominant role. The applicability of the PLM index should be tested in future studies using naturally-occurring tissue cracks.

    Matched MeSH terms: Microscopy, Polarization/methods
  2. Zain E, Zakian CM, Chew HP
    J Dent, 2018 04;71:31-37.
    PMID: 29378225 DOI: 10.1016/j.jdent.2018.01.009
    OBJECTIVE: The main objective of this study was to evaluate the accuracy of optical coherence tomography (OCT) in detecting naturally occurring non-cavitated fissure caries (NCFC) in totality and at different loci by visually assessing cross-sectional OCT scans (B-scan) with an interpretation criterion. The secondary objective was to evaluate the agreement between dimensions of NCFC measured with OCT and polarized light microscopy (PLM).

    METHODS: 71 investigation sites of sound fissure and naturally occurring NCFC on human extracted premolars were identified and scanned with a swept-source OCT. The teeth were then sectioned bucco-lingually at the investigation sites and imaged using PLM. Two calibrated examiners trained on the B-scan NCFC visual interpretation criteria established for this study, assessed the investigation sites and results were validated against PLM.

    RESULTS: Detection sensitivity of B-scan for NCFC when fissures were assessed in totality, or on the slopes or walls separately are 0.98, 0.95, 0.94 and specificity are 0.95, 0.90, and 0.95. One-way ANOVA showed that width measurements of wall loci done with OCT and PLM were not statistically different. However, OCT height measurements of slope loci were statistically bigger with a constant bias of 0.08 mm (of which is not clinically significant) and OCT height measurements of wall loci were statistically smaller (0.57 mm) and Bland-Altman plots indicated presence of proportionate bias.

    CONCLUSION: Visual assessment of B-scans with the interpretation criteria resulted in both high specificity and sensitivity and were not affected by loci location. OCT width measurement of wall loci is in agreement with PLM.

    CLINICAL SIGNIFICANCE: Unanimous high sensitivity in this and previous studies indicate that visual assessment of B-scans reliably rule out NCFC. Detection accuracy was not affected by loci location. Width of wall loci and/or height of slope loci in OCT B-scan are to be used for monitoring NCFC but not height of wall loci.

    Matched MeSH terms: Microscopy, Polarization/methods
Related Terms
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links