Displaying publications 1 - 20 of 169 in total

Abstract:
Sort:
  1. Keun Seon J, Anwar Ayob K, Giun Noh M, Yeol Yang H
    Acta Orthop Traumatol Turc, 2024 Jan;58(1):68-72.
    PMID: 38525513 DOI: 10.5152/j.aott.2024.23115
    Oxidized zirconium (OxiniumTM) prostheses, made up of a metallic alloy of zirconium with a ceramic surface formed by oxidizing the outer layer, were developed as an alternative bearing surface to reduce polyethylene wear and decrease failure of total knee arthroplasty (TKA). We report a unique catastrophic failure of an Oxinium TKA with consequent accelerated wear and severe metallosis. Intraoperatively, we observed extensive wear grooving of the femoral component with exposure of the underlying silver layers and the complete wear of polyethylene on the medial side. Metallic debris had a peculiar arthrogram appearance, noted within the cut surface of the femur and tibia, indicative of the osteolysis that occurred, leading up to the failure of the implants. The histopathologic examination revealed a collection of macrophages with foreign-body reactions and black-pigmented metal-induced wear particles. Oxinium has clear benefits regarding superior wear properties; however, surgeons need to be aware that there is a risk of exposure to the underlying layers that may precede accelerated wear, deformation, and metallosis. Uncovering the deeper layers could result in the appearance of an arthrogram on plain radiographs. Early identification of polyethylene wear and prompt revision is crucial to avoid the rapid progression of subsequent metallosis and catastrophic implant failure, specifically when using oxidized zirconium components for TKA. To the best of our knowledge, this is the first report presenting a detailed histologic analysis to provide insight into the mechanisms of the failed Oxinium components.
    Matched MeSH terms: Prosthesis Design
  2. Eshraghi A, Abu Osman NA, Gholizadeh H, Ali S, Abas WA
    Am J Phys Med Rehabil, 2015 Jan;94(1):1-10.
    PMID: 24919079 DOI: 10.1097/PHM.0000000000000134
    This study aimed to compare the effects of different suspension methods on the interface stress inside the prosthetic sockets of transtibial amputees when negotiating ramps and stairs.
    Matched MeSH terms: Prosthesis Design
  3. Gholizadeh H, Abu Osman NA, Eshraghi A, Ali S
    Am J Phys Med Rehabil, 2014 Sep;93(9):809-23.
    PMID: 24743451 DOI: 10.1097/PHM.0000000000000094
    The purpose of this study was to find the scientific evidence pertaining to various transfemoral suspension systems to provide selection criteria for clinicians. To this end, databases of PubMed, Web of Science, and ScienceDirect were explored. The following key words, as well as their combinations and synonyms, were used for the search: transfemoral prosthesis, prosthetic suspension, lower limb prosthesis, above-knee prosthesis, prosthetic liner, transfemoral, and prosthetic socket. The study design, research instrument, sampling method, outcome measures, and protocols of articles were reviewed. On the basis of the selection criteria, 16 articles (11 prospective studies and 5 surveys) were reviewed. The main causes of reluctance to prosthesis, aside from energy expenditure, were socket-related problems such as discomfort, perspiration, and skin problems. Osseointegration was a suspension option, yet it is rarely applied because of several drawbacks, such as extended rehabilitation process, risk for fracture, and infection along with excessive cost. In conclusion, no clinical evidence was found as a "standard" system of suspension and socket design for all transfemoral amputees. However, among various suspension systems for transfemoral amputees, the soft insert or double socket was favored by most users in terms of function and comfort.
    Matched MeSH terms: Prosthesis Design*
  4. Abd Razak NA, Abu Osman NA, Kamyab M, Wan Abas WA, Gholizadeh H
    Am J Phys Med Rehabil, 2014 May;93(5):437-44.
    PMID: 24429510 DOI: 10.1097/PHM.0b013e3182a51fc2
    This report compares wrist supination and pronation and flexion and extension movements with the common body-powered prosthesis and a new biomechatronics prosthesis with regard to patient satisfaction and problems experienced with the prosthesis. Fifteen subjects with traumatic transradial amputation who used both prosthetic systems participated in this study. Each subject completed two questionnaires to evaluate their satisfaction and problems experienced with the two prosthetic systems. Satisfaction and problems with the prosthetic's wrist movements were analyzed in terms of the following: supination and pronation; flexion and extension; appearance; sweating; wounds; pain; irritation; pistoning; smell; sound; durability; and the abilities to open a door, hold a cup, and pick up or place objects. This study revealed that the respondents were more satisfied with the biomechatronics wrist prosthesis with regard to supination and pronation, flexion and extension, pain, and the ability to open a door. However, satisfaction with the prosthesis showed no significant differences in terms of sweating, wounds, irritation, pistoning, smell, sound, and durability. The abilities to hold a cup and pick up or place an object were significantly better with the body-powered prosthesis. The results of the survey suggest that satisfaction and problems with wrist movements in persons with transradial amputation can be improved with a biomechatronics wrist prosthesis compared with the common body-powered prosthesis.
    Matched MeSH terms: Prosthesis Design*
  5. Gholizadeh H, Abu Osman NA, Kamyab M, Eshraghi A, Lúvíksdóttir AG, Wan Abas WA
    Am J Phys Med Rehabil, 2012 Oct;91(10):894-8.
    PMID: 22173083
    The effects of Seal-In X5 and Dermo liner (Össur) on suspension and patient's comfort in lower limb amputees are unclear. In this report, we consider the case of a 51-yr-old woman with bilateral transtibial amputation whose lower limbs were amputated because of peripheral vascular disease. The subject had bony and painful residual limbs, especially at the distal ends. Two prostheses that used Seal-In X5 liners and a pair of prostheses with Dermo liners were fabricated, and the subject wore each for a period of 2 wks. Once the 2 wks had passed, the pistoning within the socket was assessed and the patient was questioned as to her satisfaction with both liners. This study revealed that Seal-In X5 liner decreased the residual limb pain experienced by the patient and that 1-2 mm less pistoning occurred within the socket compared with the Dermo liner. However, the patient needed to put in extra effort for donning and doffing the prosthesis. Despite this, it is clear that the Seal-In X5 liner offers a viable alternative for individuals with transtibial amputations who do not have enough soft tissue around the bone, especially at the end of the residual limb.
    Matched MeSH terms: Prosthesis Design/instrumentation*; Prosthesis Design/methods
  6. Eshraghi A, Abu Osman NA, Karimi MT, Gholizadeh H, Ali S, Wan Abas WA
    Am J Phys Med Rehabil, 2012 Dec;91(12):1028-38.
    PMID: 23168378 DOI: 10.1097/PHM.0b013e318269d82a
    The objectives of this study were to compare the effects of a newly designed magnetic suspension system with that of two existing suspension methods on pistoning inside the prosthetic socket and to compare satisfaction and perceived problems among transtibial amputees.
    Matched MeSH terms: Prosthesis Design*
  7. Noorsal E, Sooksood K, Bihr U, Becker J, Ortmanns M
    PMID: 23366775 DOI: 10.1109/EMBC.2012.6346814
    This paper describes how to employ distributed clock gating to achieve an overall low power design of a programmable waveform generator intended for a neural stimulator. The power efficiency is enabled using global timing control combined with local amplitude distribution over a bus to the local stimulator frontends. This allows the combination of local and global clock gating for complete sub-blocks of the design. A counter and a shifter employed at the local digital stimulator reduce the design complexity for the waveform generation and thus the overall power consumptions. The average power results indicate that 63% power can be saved for the global stimulator control unit and 89-96% power can be saved for the local digital stimulator by using the proposed approach. The circuit has been implemented and successfully tested in a 0.35 µm AMS HVCMOS technology.
    Matched MeSH terms: Prosthesis Design*
  8. Oshkour AA, Talebi H, Seyed Shirazi SF, Yau YH, Tarlochan F, Abu Osman NA
    Artif Organs, 2015 Feb;39(2):156-64.
    PMID: 24841371 DOI: 10.1111/aor.12315
    This study aimed to assess the performance of different longitudinal functionally graded femoral prostheses. This study was also designed to develop an appropriate prosthetic geometric design for longitudinal functionally graded materials. Three-dimensional models of the femur and prostheses were developed and analyzed. The elastic modulus of these prostheses in the sagittal plane was adjusted along a gradient direction from the distal end to the proximal end. Furthermore, these prostheses were composed of titanium alloy and hydroxyapatite. Results revealed that strain energy, interface stress, and developed stress in the femoral prosthesis and the bone were influenced by prosthetic geometry and gradient index. In all of the prostheses with different geometries, strain energy increased as gradient index increased. Interface stress and developed stress decreased. The minimum principal stress and the maximum principal stress of the bone slightly increased as gradient index increased. Hence, the combination of the femoral prosthetic geometry and functionally graded materials can be employed to decrease stress shielding. Such a combination can also be utilized to achieve equilibrium in terms of the stress applied on the implanted femur constituents; thus, the lifespan of total hip replacement can be prolonged.
    Matched MeSH terms: Prosthesis Design
  9. Baharuddin MY, Salleh ShH, Suhasril AA, Zulkifly AH, Lee MH, Omar MA, et al.
    Artif Organs, 2014 Jul;38(7):603-8.
    PMID: 24404766 DOI: 10.1111/aor.12222
    Total hip arthroplasty is a flourishing orthopedic surgery, generating billions of dollars of revenue. The cost associated with the fabrication of implants has been increasing year by year, and this phenomenon has burdened the patient with extra charges. Consequently, this study will focus on designing an accurate implant via implementing the reverse engineering of three-dimensional morphological study based on a particular population. By using finite element analysis, this study will assist to predict the outcome and could become a useful tool for preclinical testing of newly designed implants. A prototype is then fabricated using 316L stainless steel by applying investment casting techniques that reduce manufacturing cost without jeopardizing implant quality. The finite element analysis showed that the maximum von Mises stress was 66.88 MPa proximally with a safety factor of 2.39 against endosteal fracture, and micromotion was 4.73 μm, which promotes osseointegration. This method offers a fabrication process of cementless femoral stems with lower cost, subsequently helping patients, particularly those from nondeveloped countries.
    Matched MeSH terms: Prosthesis Design
  10. Salamonsen RF, Lim E, Moloney J, Lovell NH, Rosenfeldt FL
    Artif Organs, 2015 Aug;39(8):681-90.
    PMID: 26146861 DOI: 10.1111/aor.12550
    This study in five large greyhound dogs implanted with a VentrAssist left ventricular assist device focused on identification of the precise site and physiological changes induced by or underlying the complication of left ventricular suction. Pressure sensors were placed in left and right atria, proximal and distal left ventricle, and proximal aorta while dual perivascular and tubing ultrasonic flow meters measured blood flow in the aortic root and pump outlet cannula. When suction occurred, end-systolic pressure gradients between proximal and distal regions of the left ventricle on the order of 40-160 mm Hg indicated an occlusive process of variable intensity in the distal ventricle. A variable negative flow difference between end systole and end diastole (0.5-3.4 L/min) was observed. This was presumably mediated by variable apposition of the free and septal walls of the ventricle at the pump inlet cannula orifice which lasted approximately 100 ms. This apposition, by inducing an end-systolic flow deficit, terminated the suction process by relieving the imbalance between pump requirement and delivery from the right ventricle. Immediately preceding this event, however, unnaturally low end-systolic pressures occurred in the left atrium and proximal left ventricle which in four dogs lasted for 80-120 ms. In one dog, however, this collapse progressed to a new level and remained at approximately -5 mm Hg across four heart beats at which point suction was relieved by manual reduction in pump speed. Because these pressures were associated with a pulmonary capillary wedge pressure of -5 mm Hg as well, they indicate total collapse of the entire pulmonary venous system, left atrium, and left ventricle which persisted until pump flow requirement was relieved by reducing pump speed. We suggest that this collapse caused the whole vascular region from pulmonary capillaries to distal left ventricle to behave as a Starling resistance which further reduced right ventricular output thus contributing to a major reduction in pump flow. We contend that similar complications of manual speed control also occur in the human subject and remain a major unsolved problem in the clinical management of patients implanted with rotary blood pumps.
    Matched MeSH terms: Prosthesis Design
  11. Abbas SS, Nasif MS, Al-Waked R, Meor Said MA
    Artif Organs, 2020 Feb;44(2):E20-E39.
    PMID: 31378963 DOI: 10.1111/aor.13536
    Platelet activation induced by shear stresses and non-physiological flow field generated by bileaflet mechanical heart valves (BMHVs) leads to thromboembolism, which can cause fatal consequences. One of the causes of platelet activation could be intermittent regurgitation, which arises due to asynchronous movement and rebound of BMHV leaflets during the valve closing phase. In this numerical study, the effect of intermittent regurgitation on the platelet activation potential of BMHVs was quantified by modeling a BMHV in the straight and anatomic aorta at implantation tilt angles 0°, 5°, 10°, and 20°. A fully implicit Arbitrary Lagrangian-Eulerian-based Fluid-Structure Interaction formulation was adopted with blood modeled as a multiphase, non-Newtonian fluid. Results showed that the intermittent regurgitation and consequently the platelet activation level increases with the increasing implantation tilt of BMHV. For the straight aorta, the leaflet of the 20° tilted BMHV underwent a rebound of approximately 20° after initially closing, whereas the leaflet of the 10°, 5°, and 0° tilted BMHVs underwent a rebound of 8.5°, 3°, and 0°, respectively. For the anatomic aorta, the leaflet of the 20° tilted BMHV underwent a rebound of approximately 24° after initially closing, whereas the leaflet of the 10°, 5°, and 0° tilted BMHVs underwent a rebound of 14°, 10°, and 7°, respectively. For all the implantation orientations of BMHVs, intermittent regurgitation and platelet activation were always higher in the anatomic aorta than in the straight aorta. The study concludes that the pivot axis of BMHV must be implanted parallel to the aortic root's curvature to minimize intermittent regurgitation and platelet activation.
    Matched MeSH terms: Prosthesis Design
  12. Alkhatib SE, Tarlochan F, Mehboob H, Singh R, Kadirgama K, Harun WSBW
    Artif Organs, 2019 Jul;43(7):E152-E164.
    PMID: 30805945 DOI: 10.1111/aor.13444
    The mismatch between stiffness of the femoral dense stem and host bone causes complications to patients, such as aseptic loosening and bone resorption. Three-dimensional finite-element models of homogeneous porous (HGP) and functionally graded porous (FGP) stems incorporating body-centered cubic (BCC) structures are proposed in this article as an alternative to the dense stems. The relationship between the porosity and strut thickness of the BCC structure was developed to construct the finite-element models. Three levels of porosities (20%, 50%, and 80%) were modeled in HGP and FGP stems. The porosity of the stems was decreased distally according to the sigmoid function (n = 0.1, n = 1 and n = 10) with 3 grading exponents. The results showed that FGP stems transferred 120%-170% higher stresses to the femur (Gruen zone 7) as compared to the solid stem. Conversely, the stresses in HGP and FGP stems were 12%-34% lower than the dense stem. The highest micromotions (105-147 µm) were observed for stems of 80% overall porosity, and the lowest (42-46 µm) was for stems of 20% overall porosity. Finally, FGP stems with a grading exponent of n = 10 resulted in an 11%-28% reduction in micromotions.
    Matched MeSH terms: Prosthesis Design
  13. Ng KL, Nawawi O, Lim BK, Htun TH, Dublin N, Razack AH
    Asian J Surg, 2017 Apr;40(2):171-174.
    PMID: 24210538 DOI: 10.1016/j.asjsur.2013.09.012
    Ureteric strictures are common and can be due to benign or malignant causes. Various surgical treatments can be used from minimally invasive endoscopic retrograde JJ stent insertion, balloon dilatation, ureterolithotomy, to open surgical exploration and repair. Memokath 051 stent is a metallic stent designed for long-term ureteral stenting in the management of ureteral strictures. The insertion of this device is usually a straightforward procedure performed endoscopically in a retrograde fashion via cystoscopy. However, this procedure can be difficult in complicated scenarios when the bladder has been removed with neoureteral reimplantations or high-grade strictures. Here, we report a case of Memokath stent insertion complicated by placement difficulties in a lady with ileal conduit due to previous ovarian cancer complicated by vesicovaginal fistula, who presented with malignant stricture of the ureteroileal anastomosis. We describe a simple yet effective antegrade technique to precisely reposition the malpositioned Memokath stent, along with illustrations.
    Matched MeSH terms: Prosthesis Design
  14. Al-Hashedi AA, Taiyeb-Ali TB, Yunus N
    Aust Dent J, 2016 06;61(2):208-18.
    PMID: 25966305 DOI: 10.1111/adj.12337
    BACKGROUND: Short dental implants can be an alternative to bone augmentation procedures at sites of reduced alveolar bone. Most studies on short implants are retrospective or multicentre reports that lack controlled and consistent comparison between different systems. This study aimed to compare clinical and radiographic outcomes of short implants in two different systems in the posterior mandible.

    METHODS: Twenty patients with two adjacent missing posterior teeth were recruited. Patients were assigned equally and randomly into two groups; Bicon(®) (6 or 8 mm) and Ankylos(®) (8 mm) implants. A two-stage surgical approach and single crowns were used for implant placement and loading. Outcomes included peri-implant clinical parameters, implant stability (Periotest values; PTVs) and peri-implant bone changes, which were assessed at baseline, 2, 6 and 12 months post-loading.

    RESULTS: No implant loss was encountered up to 12 months post-loading. No significant difference in the clinical or radiographic parameters was observed except for PTVs (p < 0.05) that was lower in Ankylos(®) implants.

    CONCLUSIONS: The use of short dental implants was associated with excellent 12 months clinical and radiographic outcomes. Ankylos(®) and Bicon(®) implants demonstrated similar peri-implant soft tissue and alveolar bone changes. However, Ankylos(®) implants demonstrated better implant stability at all evaluation intervals.

    Matched MeSH terms: Dental Prosthesis Design
  15. Baharuddin MY, Salleh ShH, Zulkifly AH, Lee MH, Noor AM, A Harris AR, et al.
    PMID: 24484753 DOI: 10.1186/1471-2474-15-30
    Minimal available information concerning hip morphology is the motivation for several researchers to study the difference between Asian and Western populations. Current use of a universal hip stem of variable size is not the best option for all femur types. This present study proposed a new design process of the cementless femoral stem using a three dimensional model which provided more information and accurate analysis compared to conventional methods.
    Matched MeSH terms: Prosthesis Design*
  16. Choy WJ, Phan K, Diwan AD, Ong CS, Mobbs RJ
    BMC Musculoskelet Disord, 2018 Aug 16;19(1):290.
    PMID: 30115053 DOI: 10.1186/s12891-018-2213-5
    BACKGROUND: Lumbar intervertebral disc herniation is a common cause of lower back and leg pain, with surgical intervention (e.g. discectomy to remove the herniated disc) recommended after an appropriate period of conservative management, however the existing or increased breach of the annulus fibrosus persists with the potential of reherniation. Several prosthesis and techniques to reduce re-herniation have been proposed including implantation of an annular closure device (ACD) - Barricaid™ and an annular tissue repair system (AR) - Anulex-Xclose™. The aim of this meta-analysis is to assist surgeons determine a potential approach to reduce incidences of recurrent lumbar disc herniation and assess the current devices regarding their outcomes and complications.

    METHODS: Four electronic full-text databases were systematically searched through September 2017. Data including outcomes of annular closure device/annular repair were extracted. All results were pooled utilising meta-analysis with weighted mean difference and odds ratio as summary statistics.

    RESULTS: Four studies met inclusion criteria. Three studies reported the use of Barricaid (ACD) while one study reported the use of Anulex (AR). A total of 24 symptomatic reherniation were reported among 811 discectomies with ACD/AR as compared to 51 out of 645 in the control group (OR: 0.34; 95% CI: 0.20,0.56; I2 = 0%; P 

    Matched MeSH terms: Prosthesis Design
  17. Kaur K
    BMJ Case Rep, 2023 Feb 14;16(2).
    PMID: 36787931 DOI: 10.1136/bcr-2022-251154
    Long-term prognosis of complicated traumatic injuries depends on precise treatment planning. Establishing a balance between a patient's age, prognosis, financial hurdles, and treatment needs is challenging. This case highlights the need for meticulous and realistic treatment planning to achieve long-term favourable outcomes in traumatic injuries in young adults.A young child sustained a traumatic injury that caused avulsion of #21 and intrusion along with palatal luxation of #11. The child reported to the dental clinic with intraoral swelling and pain a week after the injury. Socket preservation was done so that uniform bone contour could be achieved for implant placement at a later stage. We modified a 'Hollywood appliance' as an interim prosthesis to ensure that the ridge was not immediately loaded where socket preservation was done.After a follow-up of 3 years, there is significant bone deposition and the child is satisfied with aesthetics.
    Matched MeSH terms: Prosthesis Design
  18. Baharuddin MY, Salleh ShH, Zulkifly AH, Lee MH, Mohd Noor A
    Biomed Res Int, 2014;2014:692328.
    PMID: 25025068 DOI: 10.1155/2014/692328
    A morphology study was essential to the development of the cementless femoral stem because accurate dimensions for both the periosteal and endosteal canal ensure primary fixation stability for the stem, bone interface, and prevent stress shielding at the calcar region. This paper focused on a three-dimensional femoral model for Asian patients that applied preoperative planning and femoral stem design. We measured various femoral parameters such as the femoral head offset, collodiaphyseal angle, bowing angle, anteversion, and medullary canal diameters from the osteotomy level to 150 mm below the osteotomy level to determine the position of the isthmus. Other indices and ratios for the endosteal canal, metaphyseal, and flares were computed and examined. The results showed that Asian femurs are smaller than Western femurs, except in the metaphyseal region. The canal flare index (CFI) was poorly correlated (r < 0.50) to the metaphyseal canal flare index (MCFI), but correlated well (r = 0.66) with the corticomedullary index (CMI). The diversity of the femoral size, particularly in the metaphyseal region, allows for proper femoral stem design for Asian patients, improves osseointegration, and prolongs the life of the implant.
    Matched MeSH terms: Prosthesis Design/methods
  19. Baharuddin MY, Salleh ShH, Hamedi M, Zulkifly AH, Lee MH, Mohd Noor A, et al.
    Biomed Res Int, 2014;2014:478248.
    PMID: 24800230 DOI: 10.1155/2014/478248
    Stress shielding and micromotion are two major issues which determine the success of newly designed cementless femoral stems. The correlation of experimental validation with finite element analysis (FEA) is commonly used to evaluate the stress distribution and fixation stability of the stem within the femoral canal. This paper focused on the applications of feature extraction and pattern recognition using support vector machine (SVM) to determine the primary stability of the implant. We measured strain with triaxial rosette at the metaphyseal region and micromotion with linear variable direct transducer proximally and distally using composite femora. The root mean squares technique is used to feed the classifier which provides maximum likelihood estimation of amplitude, and radial basis function is used as the kernel parameter which mapped the datasets into separable hyperplanes. The results showed 100% pattern recognition accuracy using SVM for both strain and micromotion. This indicates that DSP could be applied in determining the femoral stem primary stability with high pattern recognition accuracy in biomechanical testing.
    Matched MeSH terms: Prosthesis Design