Displaying all 2 publications

Abstract:
Sort:
  1. Rijal OM, Ebrahimian H, Noor NM, Hussin A, Yunus A, Mahayiddin AA
    Comput Math Methods Med, 2015;2015:424970.
    PMID: 25918551 DOI: 10.1155/2015/424970
    A novel procedure using phase congruency is proposed for discriminating some lung disease using chest radiograph. Phase congruency provides information about transitions between adjacent pixels. Abrupt changes of phase congruency values between pixels may suggest a possible boundary or another feature that may be used for discrimination. This property of phase congruency may have potential for deciding between disease present and disease absent where the regions of infection on the images have no obvious shape, size, or configuration. Five texture measures calculated from phase congruency and Gabor were shown to be normally distributed. This gave good indicators of discrimination errors in the form of the probability of Type I Error (δ) and the probability of Type II Error (β). However, since 1 -  δ is the true positive fraction (TPF) and β is the false positive fraction (FPF), an ROC analysis was used to decide on the choice of texture measures. Given that features are normally distributed, for the discrimination between disease present and disease absent, energy, contrast, and homogeneity from phase congruency gave better results compared to those using Gabor. Similarly, for the more difficult problem of discriminating lobar pneumonia and lung cancer, entropy and homogeneity from phase congruency gave better results relative to Gabor.
    Matched MeSH terms: Pulmonary Medicine/methods
  2. Boo NY, Cheong KB, Cheong SK, Lye MS, Zulfiqar MA
    J Paediatr Child Health, 1997 Aug;33(4):329-34.
    PMID: 9323622
    OBJECTIVES: To compare the overall accuracy of the stable microbubble test (SM test) with measurement of level of surfactant protein A (SP-A) of tracheal aspirate for the diagnosis of respiratory distress syndrome (RDS).

    METHODOLOGY: Tracheal aspirates were obtained from neonates on ventilatory support. The SM test was carried out on specimens of tracheal aspirate immediately after collection. Levels of SP-A in tracheal aspirates were determined by enzyme-linked immunosorbent assay (ELISA) method. The results of the SM test and SP-A level of the tracheal aspirates were compared against the clinical diagnosis of RDS based on clinical, radiological and bacteriological findings.

    RESULTS: Both the median microbubble counts (6 microbubbles/mm2, range = 0-90) and median SP-A levels (100 micrograms/L, range = 0-67447) of infants with RDS were significantly lower than those of infants with no obvious lung pathology (P < 0.0001), and pneumonia (P < 0.0001). The SM test of tracheal aspirates had higher overall accuracy for the diagnosis of RDS than measurement of SP-A levels (94.6% vs 82.4%). When the receiver operating characteristic (ROC) curves of both tests for RDS were compared, the area under the ROC curve of the SM test was larger (0.9689) than that of the SP-A method (0.8965).

    CONCLUSIONS: This study showed that the SM test of tracheal aspirate was a useful bedside diagnostic test for RDS. It could be carried out at any time after birth on infants requiring ventilatory support.

    Matched MeSH terms: Pulmonary Medicine/methods
Related Terms
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links