PURPOSE: To investigate the relationship between tear ferning patterns (TFP) and non-invasive tear break-up time (NIBUT) in normal Asian subjects.
METHODS: One hundred and forty-five adults with no ocular surface disorders were recruited. TFP and NIBUT were determined. Tears were collected using a capillary tube and allowed to air dry at room temperature for 10min. TFP was later observed using a light microscope and classified according to Rolando's classification. Measurement for NIBUT was obtained using a Tearscope with the slit lamp magnification.
RESULTS: It was found that there is no significant difference between gender in TFP (Z=-1.77, P>.05) and NIBUT (Z=-1.475, P>.05). There is also no significant difference between Malay, Chinese, Indian, and other races in TFP, (H(3)=4.85, P>.05) and NIBUT (H(3)=2.18, P>.05). However, there is a significant difference between age groups of 20-29, 30-39, 40-49,and 50-60 years old in both TFP (H(3)=28.25, P
Tear stability in normal Malays with consideration of gender and age has not been reported. In this study, we measured tear stability in normal Malays using the non-invasive tear break-up time (NIBUT).