METHODS: A retrospective, non-comparative, analytical case series of all patients who received SL-TSCPC treatment from October 2018 to April 2019 at Hospital Tengku Ampuan Afzan, Pahang, Malaysia. Data was collected during the second week, sixth week, third month and sixth month follow-up. The primary outcome measure gave success rate at six months post-treatment. Secondary measures were changes in visual acuity, mean IOP reduction, mean number of IOP lowering medications reduced and ocular side effects noted during follow-up.
RESULTS: The success rate was 43.8% (seven eyes out of sixteen eyes) at six months post-treatment. The mean IOP reduced from 43.0mmHg±14.8mmHg pre-treatment to 24.7mmHg±12.0mmHg at two weeks post treatment with 42.6% reduction. Subsequently, mean IOP at sixth week, third month and sixth month were 33.8mmHg±16.9mmHg, 35.2mmHg±14.9mmHg, and 29.0mmHg±16.2mmHg respectively. Vision maintained in 13 patients, two patients had improvement in vision however, five patients had deterioration in vision. No serious ocular side effects were noted.
CONCLUSION: Subliminal TSCPC is a safe and alternative method of lowering IOP in moderate to advanced glaucoma over 6 months duration of follow-up. As it has good safety profile and repeatability, it is a good treatment option for patients with uncontrolled glaucoma.
METHODS: This prospective clinical study included consecutive Asian patients with dark irides and confirmed for glaucoma. Only one eye of each patient was treated. Diode laser contact transscleral cyclophotocoagulation treatment was performed with the center of the probe placed 1.5 mm behind the limbus. About 30 pulses of 810-mm laser radiation (power, 1.8 to 2.0 W; duration, 0.3 to 0.5 second) were applied around the eye. Patients were examined at fixed postoperative intervals. Intraocular pressure levels and postoperative complications were recorded. The relation between patient and disease characteristics, total laser energy delivered, and intraocular pressure effects were analyzed.
RESULTS: Thirty-three patients were studied, with a mean follow-up period of 9.4 months. An average 56% of patients showed a 30% or greater drop in intraocular pressure. About 38% of patients achieved sustained intraocular pressure lowering to below 22 mm Hg at 18 months. Complications were few and included transient hypotony and iritis.
CONCLUSIONS: In Asian patients with refractory glaucoma or painful glaucomatous eyes with poor visual acuity (defined for this study as worse than 20/200), low-energy-setting diode laser contact transscleral cyclophotocoagulation by means of the glass ball probe is relatively effective and safe.