Displaying all 12 publications

Abstract:
Sort:
  1. Marconi G, Gopalai AA, Chauhan S
    Med Eng Phys, 2023 Feb;112:103951.
    PMID: 36842774 DOI: 10.1016/j.medengphy.2023.103951
    Powered ankle-foot orthoses can be utilised to overcome gait abnormalities such as foot drop; however, normal gait is rarely restored with compensatory gait patterns arising and prevalence of gait asymmetry. Therefore, this study aims to determine the effect of orthosis mass and mass distribution on the swing phase of gait, to understand residual gait asymmetry with orthosis use. Using a triple compound pendulum model, which accounts for mass distribution of the limb and orthosis, the swing phase of gait is simulated in terms of natural dynamics and the effect of an orthosis on kinematic parameters is quantitatively determined. It was found that additional mass causes faster and shorter steps on the affected side due to rapid knee extension and reduced hip flexion, with particular actuator positions and natural cadence causing varying severity of these effects. Our study suggests that this model could be used as a preliminary design tool to identify subject specific optimum orthosis mass distribution of a powered ankle-foot orthosis, without the need for motion data or experimental trials. This optimisation intends to more accurately mimic natural swing phase kinematics, consequently allowing for the reduction in severity of gait asymmetry and the potential to improve rehabilitative outcomes.
    Matched MeSH terms: Foot Orthoses*
  2. Abbott CA, Chatwin KE, Foden P, Hasan AN, Sange C, Rajbhandari SM, et al.
    Lancet Digit Health, 2019 10;1(6):e308-e318.
    PMID: 33323253 DOI: 10.1016/S2589-7500(19)30128-1
    BACKGROUND: Prevention of diabetic foot ulcer recurrence in high risk patients, using current standard of care methods, remains a challenge. We hypothesised that an innovative intelligent insole system would be effective in reducing diabetic foot ulcer recurrence in such patients.

    METHODS: In this prospective, randomised, proof-of-concept study, patients with diabetes, and with peripheral neuropathy and a recent history of plantar foot ulceration were recruited from two multidisciplinary outpatient diabetic foot clinics in the UK, and were randomly assigned to either intervention or control. All patients received an insole system, which measured plantar pressure continuously during daily life. The intervention group received audiovisual alerts via a smartwatch linked to the insole system and offloading instructions when aberrant pressures were detected; the control group did not receive any alerts. The primary outcome was plantar foot ulcer occurrence within 18 months. This trial is registered with ISRCTN, ISRCTN05585501, and is closed to accrual and complete.

    FINDINGS: Between March 18, 2014, and Dec 20, 2016, 90 patients were recruited and consented to the study, and 58 completed the study. At follow-up, ten ulcers from 8638 person-days were recorded in the control group and four ulcers from 11 835 person-days in the intervention group: a 71% reduction in ulcer incidence in the intervention group compared with the control group (incidence rate ratio 0·29, 95% CI, 0·09-0·93; p=0·037). The number of patients who ulcerated was similar between groups (six of 26 [control group] vs four of 32 [intervention group]; p=0·29); however, individual plantar sites ulcerated more often in the control group (ten of 416) than in the intervention group (four of 512; p=0·047). In an exploratory analysis of good compliers (n=40), ulcer incidence was reduced by 86% in the intervention group versus control group (incidence rate ratio 0·14, 95% CI 0·03-0·63; p=0·011). In the exploratory analysis, plantar callus severity (change from baseline to 6 months) was greater in re-ulcerating patients (6·5, IQR 4·0-8·3) than non-re-ulcerating patients (2·0, 0·0-4·8; p=0·040).

    INTERPRETATION: To our knowledge, this study is the first to show that continuous plantar pressure monitoring and dynamic offloading guidance, provided by an innovative intelligent insole system, can lead to a reduction in diabetic foot ulcer site recurrence.

    FUNDING: Diabetes UK and Orpyx Medical Technologies.

    Matched MeSH terms: Foot Orthoses*
  3. Marconi G, Gopalai AA, Chauhan S
    Med Biol Eng Comput, 2023 May;61(5):1167-1182.
    PMID: 36689083 DOI: 10.1007/s11517-023-02778-2
    This simulation study aimed to explore the effects of mass and mass distribution of powered ankle-foot orthoses, on net joint moments and individual muscle forces throughout the lower limb. Using OpenSim inverse kinematics, dynamics, and static optimization tools, the gait cycles of ten subjects were analyzed. The biomechanical models of these subjects were appended with ideal powered ankle-foot orthoses of different masses and actuator positions, as to determine the effect that these design factors had on the subject's kinetics during normal walking. It was found that when the mass of the device was distributed more distally and posteriorly on the leg, both the net joint moments and overall lower limb muscle forces were more negatively impacted. However, individual muscle forces were found to have varying results which were attributed to the flow-on effect of the orthosis, the antagonistic pairing of muscles, and how the activity of individual muscles affect each other. It was found that mass and mass distribution of powered ankle-foot orthoses could be optimized as to more accurately mimic natural kinetics, reducing net joint moments and overall muscle forces of the lower limb, and must consider individual muscles as to reduce potentially detrimental muscle fatigue or muscular disuse. OpenSim modelling method to explore the effect of mass and mass distribution on muscle forces and joint moments, showing potential mass positioning and the effects of these positions, mass, and actuation on the muscle force integral.
    Matched MeSH terms: Foot Orthoses*
  4. Shahar FS, Hameed Sultan MT, Lee SH, Jawaid M, Md Shah AU, Safri SNA, et al.
    J Mech Behav Biomed Mater, 2019 11;99:169-185.
    PMID: 31357064 DOI: 10.1016/j.jmbbm.2019.07.020
    Since ancient Egypt, orthosis was generally made from wood and then later replaced with metal and leather which are either heavy, bulky, or thick decreasing comfort among the wearers. After the age of revolution, the manufacturing of products using plastics and carbon composites started to spread due to its low cost and form-fitting feature whereas carbon composite were due to its high strength/stiffness to weight ratio. Both plastic and carbon composite has been widely applied into medical devices such as the orthosis and prosthesis. However, carbon composite is also quite expensive, making it the less likely material to be used as an Ankle-Foot Orthosis (AFO) material whereas plastics has low strength. Kenaf composite has a high potential in replacing all the current materials due to its flexibility in controlling the strength to weight ratio properties, cost-effectiveness, abundance of raw materials, and biocompatibility. The aim of this review paper is to discuss on the possibility of using kenaf composite as an alternative material to fabricate orthotics and prosthetics. The discussion will be on the development of orthosis since ancient Egypt until current era, the existing AFO materials, the problems caused by these materials, and the possibility of using a Kenaf fiber composite as a replacement of the current materials. The results show that Kenaf composite has the potential to be used for fabricating an AFO due to its tensile strength which is almost similar to polypropylene's (PP) tensile strength, and the cheap raw material compared to other type of materials.
    Matched MeSH terms: Foot Orthoses/history*; Foot Orthoses/trends*
  5. Abdul Yamin NAA, Basaruddin KS, Salleh AF, Salim MS, Wan Muhamad WZA
    Appl Bionics Biomech, 2021;2021:8842591.
    PMID: 33603827 DOI: 10.1155/2021/8842591
    Objective: The aim of this study was to investigate the effects of surface stiffness on multisegment foot kinematics and temporal parameters during running.

    Methods: Eighteen male subjects ran on three different surfaces (i.e., concrete, artificial grass, and rubber) in both heeled running shoes (HS) and minimal running shoes (MS). Both these shoes had dissimilar sole profiles. The heeled shoes had a higher sole at the heel, a thick base, and arch support, whereas the minimal shoes had a flat base sole. Indeed, the studied biomechanical parameters responded differently in the different footwear during running. Subjects ran in recreational mode speed while 3D foot kinematics (i.e., joint rotation and peak medial longitudinal arch (MLA) angle) were determined using a motion capture system (Qualysis, Gothenburg, Sweden). Information on stance time and plantar fascia strain (PFS) was also collected.

    Results: Running on different surface stiffness was found to significantly affect the peak MLA angles and stance times for both HS and MS conditions. However, the results showed that the joint rotation angles were not sensitive to surface stiffness. Also, PFS showed no relationship with surface stiffness, as the results were varied as the surface stiffness was changed.

    Conclusion: The surface stiffness significantly contributed towards the effects of peak MLA angle and stance time. These findings may enhance the understanding of biomechanical responses on various running surfaces stiffness in different shoe conditions.

    Matched MeSH terms: Foot Orthoses
  6. Bagherzadeh Cham M, Ghasemi MS, Forogh B, Sanjari MA, Zabihi Yeganeh M, Eshraghi A
    Prosthet Orthot Int, 2014 Aug;38(4):310-5.
    PMID: 23986467 DOI: 10.1177/0309364613498537
    BACKGROUND: Rheumatoid arthritis is a chronic inflammatory joint disease which affects the joints and soft tissues of the foot and ankle. Rocker shoes may be prescribed for the symptomatic foot in rheumatoid arthritis; however, there is a limited evidence base to support the use of rocker shoes in these patients.
    OBJECTIVES: The aim of this study was to evaluate the effectiveness of heel-to-toe rocker shoes on pain, disability, and activity limitation in patients with rheumatoid arthritis.
    STUDY DESIGN: Clinical trial.
    METHODS: Seventeen female patients with rheumatoid arthritis of 1 year or more duration, disease activity score of less than 2.6, and foot and ankle pain were recruited. Heel-to-toe rocker shoe was made according to each patient's foot size. All the patients were evaluated immediately, 7 and 30 days after their first visit. Foot Function Index values were recorded at each appointment.
    RESULTS: With the use of rocker shoes, Foot Function Index values decreased in all subscales. This reduction was noted in the first visit and was maintained throughout the trials.
    CONCLUSION: Rocker shoe can improve pain, disability, and activity limitation in patients with rheumatoid foot pain. All the subjects reported improved comfort levels.
    CLINICAL RELEVANCE: The results of this study showed that high-top, heel-to-toe rocker shoe with wide toe box was effective at reducing foot and ankle pain. It was also regarded as comfortable and acceptable footwear by the patients with rheumatoid foot problems.
    KEYWORDS: Foot Function Index questionnaire; Rheumatoid arthritis; pain; rocker shoes
    Study site: Biomechanics Lab, Iran University of Medical Sciences, Tehran, Iran
    Matched MeSH terms: Foot Orthoses*
  7. Aboutorabi A, Saeedi H, Kamali M, Farahmand B, Eshraghi A, Dolagh RS
    Prosthet Orthot Int, 2014 Jun;38(3):218-23.
    PMID: 23986466 DOI: 10.1177/0309364613496111
    BACKGROUND: Flat foot in children is a common deformity in which the medial longitudinal arch is reduced or eliminated.
    OBJECTIVES: The objective of this article was to compare flat foot and healthy children on the displacement of the center of pressure and walking parameters in children with two common orthoses (functional foot orthosis and medical shoe).
    STUDY DESIGN: Comparative study.
    METHODS: This study included 30 children with flat foot and 20 healthy children as a control group. The step length and width, walking velocity, symmetry, and center of pressure (CoP) displacements were recorded and compared for three conditions: functional foot orthosis and regular shoe, a medical shoe and barefoot.
    RESULTS: The results from the CoP displacements showed that the regular shoe with functional foot orthosis caused a significant decrease in the level of displacement of the CoP in flat foot children. The findings indicated a significant improvement in symmetry of steps and walking speed with the functional foot orthosis in comparison to the medical shoe in flat foot children.
    CONCLUSION: The CoP displacement was decreased and the percentage of gait symmetry and walking speed were increased by the use of regular shoes with a functional foot orthosis in comparison to the medical shoes.
    CLINICAL RELEVANCE: An orthopaedic shoe can be expensive, and in particular heavy with most children reluctant to wear it. This study focussed on the CoP displacement and selected gait parameters with an orthopaedic shoe and functional foot orthosis, and showed that a combined prescription of a functional foot orthosis and with regular shoes may be a useful alternative for children with moderate flat foot.
    KEYWORDS: Center of pressure; flexible flat foot; functional foot orthosis; gait; medical shoe
    Matched MeSH terms: Foot Orthoses*
  8. Limpaphayom N, Sailohit P
    Malays Orthop J, 2019 Nov;13(3):28-33.
    PMID: 31890107 DOI: 10.5704/MOJ.1911.005
    Introduction: Idiopathic clubfoot or congenital talipes equinovarus (CTEV) is managed by the Ponseti method worldwide; however, the recurrence of the deformity is a challenging problem. The purpose was to review the factors associated with early recurrence of CTEV post the Ponseti method. Materials and Methods: During 2011-2016, 34 infants with 52 CTEV, who underwent the Ponseti method and a minimum follow-up period of six months, were reviewed. Twenty-two infants (65%) were male, and 18 infants (53%) had bilateral CTEV. Recurrence of CTEV was defined as a reappearance of at least one of the four components of the deformity. The association between recurrence and factors, including age, gender, bilaterality, family geography, type of principal caregiver, severity at presentation, centre where the Ponseti method was initiated, compliance to foot abduction brace (FAB), practice of stretching exercise, type of FAB, and complications of casting, were evaluated using univariate logistic regression analysis. Results: The median age at initiation of the treatment was 3.4 (IQR; 2.1-12.6) weeks. A median of six (range; 3-12) casts were required. Tenotomy was performed in 32/34 (94%) of cases. Recurrence occurred in 14/52 feet (27%) at an average follow-up period of 2.3±1.1 years. Non-compliance to FAB protocol began at an average age of 11.2±6.5 months, and significantly increased the risk of recurrence during the weaning phase [OR (95%CI)=8.4 (1.2-92.4), p=0.03]. Other factors were not associated with the recurrence. Conclusion: Non-compliance to FAB occurred early during the treatment and related to a risk of recurrence of CTEV. Physicians should encourage the parents and/or guardians to follow the protocol to decrease the risk of recurrence.
    Matched MeSH terms: Foot Orthoses
  9. Sheykhi-Dolagh R, Saeedi H, Farahmand B, Kamyab M, Kamali M, Gholizadeh H, et al.
    Prosthet Orthot Int, 2015 Jun;39(3):190-6.
    PMID: 24604086 DOI: 10.1177/0309364614521652
    BACKGROUND: Flexible flat foot is described as a reduction in the height of the medial longitudinal arch and may occur from abnormal foot pronation. A foot orthosis is thought to modify and control excessive pronation and improve arch height.
    OBJECTIVE: To compare the immediate effect of three types of orthoses on foot mobility and the arch height index in subjects with flexible flat feet.
    STUDY DESIGN: A quasi-experimental study.
    METHOD: The dorsal arch height, midfoot width, foot mobility and arch height index were assessed in 20 participants with flexible flat feet (mean age = 23.2 ± 3 years) for three different foot orthosis conditions: soft, semi-rigid and rigid University of California Biomechanics Laboratory (UCBL).
    RESULTS: Maximum midfoot width at 90% with arch mobility in the coronal plane was shown in the semi-rigid orthosis condition. The semi-rigid orthosis resulted in the highest mean foot mobility in 90% of weight bearing, and the rigid orthosis (UCBL) had the lowest mean foot mobility. The soft orthosis resulted in foot mobility between that of the rigid and the semi-rigid orthosis. UCBL orthosis showed the highest arch height index, and the semi-rigid orthosis showed the lowest mean arch height index.
    CONCLUSION: Due to its rigid structure and long medial-lateral walls, the UCBL orthosis appears to limit foot mobility. Therefore, it is necessary to make an orthosis that facilitates foot mobility in the normal range of the foot arch. Future studies should address the dynamic mobility of the foot with using various types of foot orthoses.
    CLINICAL RELEVANCE: Although there are many studies focussed on flat foot and the use of foot orthoses, the mechanism of action is still unclear. This study explored foot mobility and the influence of foot orthoses and showed that a more rigid foot orthosis should be selected based on foot mobility.
    KEYWORDS: Foot orthosis; arch height index; foot mobility magnitude
    Matched MeSH terms: Foot Orthoses/classification*
  10. Khan SJ, Khan SS, Usman J, Mokhtar AH, Abu Osman NA
    Gait Posture, 2018 03;61:243-249.
    PMID: 29413792 DOI: 10.1016/j.gaitpost.2018.01.024
    OBJECTIVE: To test the hypothesis that toe-in gait (TI) will further reduce first peak (Knee Adduction Moment) KAM and decrease balance when combined with a knee brace (KB) and laterally wedged insoles (LWI) in medial knee osteoarthritis (kOA) patients.
    PARTICIPANTS: Twenty patients with bilateral symptomatic medial kOA.
    INTERVENTIONS: 4-point leverage-based KB, full-length LWI with 5° inclination and toe-in gait (TI).
    MAIN OUTCOME MEASURES: First and second peak knee adduction moment (fKAM and sKAM respectively), balance and pain.
    METHODS: The fKAM and sKAM were determined from 3-dimensional gait analysis with six randomized conditions: (1) N (without any intervention), (2) KB, (3) KB + TI, (4) LWI, (5) LWI + TI, (6) KB + LWI + TI. Balance was assessed by Biodex Balance System using three stability settings, (i) Static (ii) Moderate dynamic setting for fall risk (FR12) and (iii) High dynamic setting for fall risk (FR8).
    RESULTS: The reduction in fKAM and sKAM was greatest (19.75% and 12%) when TI was combined with KB and LWI respectively. No change in balance was observed when TI combined with KB, and LWI and when used concurrently with both the orthosis at static and FR12 conditions. Significant balance reduction was found at FR8 for KB + TI (22.22%), and KB + LWI + TI (35.71%). Pain increased significantly for KB (258%), KB + TI (305%), LWI + TI (210%) and KB + LWI + TI (316%). LWI showed no effect on pain.
    CONCLUSIONS: There is a synergistic effect of TI when combined with KB and LWI concurrently in sKAM reduction. However, the concurrent use of TI, KB and LWI decreases balance and pain as assessed on a highly dynamic platform.
    Study site: Department of Sports Medicine, University of Malaya Medical Centre (UMMC), Kuala Lumpur, Malaysia
    Matched MeSH terms: Foot Orthoses*
  11. Khan SJ, Khan SS, Usman J, Mokhtar AH, Abu Osman NA
    Prosthet Orthot Int, 2019 Apr;43(2):148-157.
    PMID: 30192706 DOI: 10.1177/0309364618796849
    BACKGROUND:: Knee osteoarthritis is a major contributor to the global burden of disease. There is a need of reducing knee joint load and to improve balance and physical function among knee osteoarthritis patients.

    OBJECTIVES:: To test the hypothesis that toe-out gait will reduce second peak knee adduction moment further and increase fall risk when combined with knee brace and laterally wedged insole in knee osteoarthritis patients.

    STUDY DESIGN:: Single visit study with repeated measures.

    METHODS:: First and second peak knee adduction moments, fall risk and comfort level. First and second peak knee adduction moments were determined from three-dimensional gait analysis, completed under six randomized conditions: (1) natural, (2) knee brace, (3) knee brace + toe-out gait, (4) laterally wedged insole, (5) laterally wedged insole + toe-out gait, and (6) knee brace + laterally wedged insole + toe-out gait. Fall risk was assessed by Biodex Balance System using three randomized stability settings: (1) static, (2) moderate dynamic setting (FR12), and (3) high dynamic setting (FR8).

    RESULTS:: The reduction in first peak knee adduction moment and second peak knee adduction moment was greatest (7.16% and 25.55%, respectively) when toe-out gait combine with knee brace and laterally wedged insole. Significant increase in fall risk was observed with knee brace + laterally wedged insole + toe-out gait (42.85%) at FR12. Similar significant balance reductions were found at FR8 condition for knee brace + toe-out gait (35.71%), laterally wedged insole + toe-out gait (28.57%), and knee brace + laterally wedged insole + toe-out gait (50%) as compared to natural. However, knee brace decreased fall risk at FR12 by 28.57%.

    CONCLUSION:: There is a synergistic effect of toe-out when combined with knee brace and laterally wedged insole concurrently in second peak knee adduction moment reduction but with a greater degree of fall risk. Simultaneous use of conservative treatments also decreases comfort level.

    CLINICAL RELEVANCE: Patients with mild and moderate knee osteoarthritis are usually prescribed conservative treatment techniques. This study will provide an insight whether or not a combination of these techniques have a synergistic effect in reducing knee joint load.

    Matched MeSH terms: Foot Orthoses*
  12. Azizan NA, Basaruddin KS, Salleh AF, Sulaiman AR, Safar MJA, Rusli WMR
    J Healthc Eng, 2018;2018:7815451.
    PMID: 29983905 DOI: 10.1155/2018/7815451
    Balance in the human body's movement is generally associated with different synergistic pathologies. The trunk is supported by one's leg most of the time when walking. A person with poor balance may face limitation when performing their physical activities on a daily basis, and they may be more prone to having risk of fall. The ground reaction forces (GRFs), centre of pressure (COP), and centre of mass (COM) in quite standing posture were often measured for the evaluation of balance. Currently, there is still no experimental evidence or study on leg length discrepancy (LLD) during walking. Analysis of the stability parameters is more representative of the functional activity undergone by the person who has a LLD. Therefore, this study hopes to shed new light on the effects of LLD on the dynamic stability associated with VGRF, COP, and COM during walking. Eighteen healthy subjects were selected among the university population with normal BMIs. Each subject was asked to walk with 1.0 to 2.0 ms-1 of walking speed for three to five trials each. Insoles of 0.5 cm thickness were added, and the thickness of the insoles was subsequently raised until 4 cm and placed under the right foot as we simulated LLD. The captured data obtained from a force plate and motion analysis present Peak VGRF (single-leg stance) and WD (double-leg stance) that showed more forces exerted on the short leg rather than long leg. Obviously, changes occurred on the displacement of COM trajectories in the ML and vertical directions as LLD increased at the whole gait cycle. Displacement of COP trajectories demonstrated that more distribution was on the short leg rather than on the long leg. The root mean square (RMS) of COP-COM distance showed, obviously, changes only in ML direction with the value at 3 cm and 3.5 cm. The cutoff value via receiver operating characteristic (ROC) indicates the significant differences starting at the level 2.5 cm up to 4 cm in long and short legs for both AP and ML directions. The present study performed included all the proposed parameters on the effect of dynamic stability on LLD during walking and thus helps to determine and evaluate the balance pattern.
    Matched MeSH terms: Foot Orthoses