Displaying publications 21 - 26 of 26 in total

Abstract:
Sort:
  1. Suresh S, Nor-Masniwati S, Nor-Idahriani MN, Wan-Hazabbah WH, Zeehaida M, Zunaina E
    Clin Ophthalmol, 2012;6:147-50.
    PMID: 22291456 DOI: 10.2147/OPTH.S26844
    BACKGROUND: The purpose of this study was to evaluate the immunoglobulin (Ig) G avidity of serological toxoplasmosis testing in patients with ocular inflammation and to determine the clinical manifestations of ocular toxoplasmosis.

    METHODS: A retrospective review of all patients presenting with ocular inflammation to the Hospital Universiti Sains Malaysia, Kelantan, Malaysia between 2005 and 2009 was undertaken. Visual acuity, clinical manifestations at presentation, toxoplasmosis antibody testing, and treatment records were analyzed.

    RESULTS: A total of 130 patients with ocular inflammation were reviewed retrospectively. The patients had a mean age of 38.41 (standard deviation 19.24, range 6-83) years. Seventy-one patients (54.6%) were found to be seropositive, of whom five (3.8%) were both IgG and IgM positive (suggestive of recently acquired ocular toxoplasmosis) while one (0.8%) showed IgG avidity ≤40% (suggestive of recently acquired ocular toxoplasmosis) and 65 patients (50.0%) showed IgG avidity >40% (suggestive of reactivation of toxoplasmosis infection). Chorioretinal scarring as an ocular manifestation was significantly more common in patients with seropositive toxoplasmosis (P = 0.036). Eighteen patients (13.8%) were diagnosed as having recent and/or active ocular toxoplasmosis based on clinical manifestations and serological testing.

    CONCLUSION: Ocular toxoplasmosis is a clinical diagnosis, but specific toxoplasmosis antibody testing helps to support the diagnosis and to differentiate between reactivation of infection and recently acquired ocular toxoplasmosis.

  2. Tan ZN, Wong WK, Noordin R, Zeehaida M, Olivos GA, Lim BH
    Trop Biomed, 2013 Jun;30(2):250-6.
    PMID: 23959490 MyJurnal
    Entamoeba histolytica causes amoebic diarrhoea, colitis and liver abscess (ALA). Diagnosis of ALA is difficult, as most patients do not have simultaneous intestinal amoebic infection. At Hospital Universiti Sains Malaysia (HUSM), diagnosis of ALA relies on a combination of clinical findings, ultrasound examination of the liver and serodiagnosis using a commercial kit. In this study, two in-house indirect ELISAs were developed and evaluated. One of the in-house assays utilises E. histolytica crude soluble antigen (CSA) to detect serum IgG specific to the parasite whereas the other uses E. histolytica ether extract antigen (EEA). Preparation of CSA requires a sonicator to lyse the amoeba whereas EEA was prepared by chemically solubilizing the trophozoites. Based on the cut-off value of mean optical density + 3SD, CSA-ELISA showed 100% (24/24) sensitivity and 93.33% (210/225) specificity; while EEA-ELISA showed 91.67% (22/24) sensitivity and 95.11% (214/225) specificity. In conclusion, both the in-house indirect ELISAs were found to be efficacious for diagnosis of ALA; and the EEA is easier to prepare than the commonly used CSA.
  3. Zeehaida M, Wan Nor Amilah WA, Amry AR, Hassan S, Sarimah A, Rahmah N
    Trop Biomed, 2008 Dec;25(3):209-16.
    PMID: 19287359
    Amoebic serodiagnosis at Hospital Universiti Sains Malaysia (HUSM), Kelantan employs an indirect haemagglutination assay (IHA) which detects anti-Entamoeba histolytica antibodies in patients' serum samples. In an amoebiasis endemic area such as Kelantan, interpretation of a positive IHA result can be problematic due to the high background antibody levels. The TechLab E. histolytica II ELISA is a commercial kit for detection of specific Gal/GalNAc lectin antigen in stool samples, and has been reported to be able to detect the antigen in serum samples from patients with amoebic liver abscess (ALA). Thus in this study we investigated the usefulness of TechLab E. histolytica II ELISA for diagnosis of ALA by comparing it with IHA. This is a cross sectional study involving 58 suspected ALA patients who were admitted to the surgical ward, HUSM, Kelantan. The diagnosis of ALA was established based on clinical symptoms and signs, ultrasound and/or CT scan results. The serum specimens obtained from the patients were tested with IHA (Dade Behring Diagnostics, Marburg, Germany) and TechLab E. histolytica II ELISA (Techlab, Blacksburg, Virginia, USA) according to the manufacturers' instructions. Of the 58 patients, 72.4% (42) were positive by IHA and only 8.6% (5) were positive by the TechLab E. histolytica II ELISA. Agreement between the IHA and ELISA was poor (kappa value 0.019, p=0.691). There was also no correlation between ELISA results and IHA antibody titers. The TechLab E. histolytica II ELISA was not sensitive in detecting amoebic antigen in samples from ALA patients. In addition the results of the test did not correlate with the IHA anti-E. histolytica antibody titres. Therefore, the TechLab E. histolytica II ELISA was found not to be useful for serological diagnosis of ALA at HUSM.
  4. Siti Hafsyah MH, Ibrahim NR, Noraida R, Ismail AA, Anani Aila MZ, Hajissa K, et al.
    Med J Malaysia, 2021 Sep;76(5):731-733.
    PMID: 34508383
    Neonatal invasive Group A Streptococcus (GAS) infection is a rare occurrence nowadays. Prior maternal vaginal colonization is an important factor in early neonatal disease. We report a case of invasive and fatal infection in a neonate. At Day 1 of life, a term baby was found to be lethargic, with poor feeding, and later became unresponsive. Consequently, the baby was immediately brought to the Emergency Department of Hospital Universiti Sains Malaysia, Kubang Kerian, Kelantan via ambulance. Despite the active resuscitation efforts in the hospital, the baby died. An autopsy was carried out to determine the cause of death. The mother was noted to have puerperal pyrexia secondary to vaginal discharge. Her high vaginal swab culture was positive for GAS. GAS was also isolated from the intracardiac blood, pleural fluid, peritoneal fluid, and umbilical swab of the baby, giving evidence to the aetiology of the mortality. Vaginal colonization of GAS is an important factor for high morbidity and mortality for both mother and infant due to its invasiveness and virulence.
  5. Habsah H, Zeehaida M, Van Rostenberghe H, Noraida R, Wan Pauzi WI, Fatimah I, et al.
    J Hosp Infect, 2005 Nov;61(3):213-8.
    PMID: 16213372
    Contaminated parenteral nutrition (PN) is an important source of infection in neonates. Many organisms have been reported to cause contamination that results in outbreaks in intensive care units. The objective of this study was to investigate an outbreak caused by Pantoea spp., which contaminates PN, in a neonatal intensive care unit (NICU). This was a descriptive study of an outbreak of sepsis in an NICU of a tertiary teaching hospital in Malaysia. Pantoea spp. infection was detected in eight patients over a three-day period from 24 to 27 January 2004 following the administration of PN. Seven of the eight patients died due to the infection. Extensive environmental samplings for culture were performed. PN solution from the NICU and the pharmacy were also cultured during the outbreak period. Pantoea spp. was isolated from blood cultures of all infected patients, and the unused PN from the pharmacy and the NICU. All the strains of Pantoea spp. had a similar antibiotic susceptibility pattern and biochemical reaction. From the results, we concluded that PN was the source of the outbreak and the contamination may have occurred during its preparation in the pharmacy. A thorough investigation has been carried out and, where possible, corrective measures have been taken to avoid similar outbreaks in the future.
  6. Tan ZN, Wong WK, Nik Zairi Z, Abdullah B, Rahmah N, Zeehaida M, et al.
    Trop Biomed, 2010 Apr;27(1):79-88.
    PMID: 20562817 MyJurnal
    Entamoeba histolytica causes about 50 million infections worldwide with a death rate of over 100,000 annually. In endemic developing countries where resources are limited, microscopic examinations based on Wheatley trichrome staining is commonly used for diagnosis of intestinal amoebiasis. Other than being a time-consuming method, it must be performed promptly after stool collection as trophozoites disintegrate rapidly in faeces. The aim of this study was to compare the efficacies of Eosin-Y, Wheatley trichrome and Iodine stains in delineating the diagnostic features of the parasite, and subsequently to determine the suitable microscopy observation period for detection of erythrophagocytic and non-erythrophagocytic trophozoites spiked in semi-solid stool sample. Wheatley trichrome staining technique was performed using the standard method while the other two techniques were performed on the slides by mixing the respective staining solution with the spiked stool sample. One million of axenically cultured non-erythrophagocytic E. histolytica and erythrophagocytic E. histolytica were separately spiked into 2 g of fresh semisolid faeces. Percentage viability of the trophozoites in the spiked stool sample was determined at 30 minute intervals for eight hours using the 0.4% Trypan blue exclusion method. The results showed that Eosin-Y and Wheatley trichrome stained the karyosome and chromatin granules better as compared to Iodine stain. The percentage viability of non-erythrophagocytic trophozoites decreased faster than the erythrophagocytic form in the first 5 hours and both dropped to ~10% in the 6th hour spiked sample. In conclusion, Eosin-Y staining technique was found to be the easiest to perform, most rapid and as accurate as the commonly used Wheatley trichrome technique; Eosin-Y stained slide sealed with DPX could also be kept as a permanent record. A period not exceeding 6 hours after stool collection was found to be the most suitable in order to obtain good microscopy results of viable trophozoites.
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links