Displaying publications 21 - 32 of 32 in total

Abstract:
Sort:
  1. Lee YH, Quek ST, Khong PL, Lee CS, Wu JS, Zhang L, et al.
    Br J Radiol, 2020 Sep;93(1113):20200082.
    PMID: 32584595 DOI: 10.1259/bjr.20200082
    OBJECTIVE: To understand the status of pre-procedural safety practices in radiological examinations at radiology residency training institutions in various Asian regions.

    METHODS: A questionnaire based on the Joint Commission International Accreditation Standards was electronically sent to 3 institutions each in 10 geographical regions across 9 Asian countries. Questions addressing 45 practices were divided into 3 categories. A five-tier scale with numerical scores was used to evaluate safety practices in each institution. Responses obtained from three institutions in the United States were used to validate the execution rate of each surveyed safety practice.

    RESULTS: The institutional response rate was 70.0% (7 Asian regions, 21 institutions). 44 practices (all those surveyed except for the application of wrist tags for identifying patients with fall risks) were validated using the US participants. Overall, the Asian participants reached a consensus on 89% of the safety practices. Comparatively, most Asian participants did not routinely perform three pre-procedural practices in the examination appropriateness topic.

    CONCLUSION: Based on the responses from 21 participating Asian institutions, most routinely perform standard practices during radiological examinations except when it comes to examination appropriateness. This study can provide direction for safety policymakers scrutinizing and improving regional standards of care.

    ADVANCES IN KNOWLEDGE: This is the first multicenter survey study to elucidate pre-procedural safety practices in radiological examinations in seven Asian regions.

  2. Lau S, Ng KH, Abdul Aziz YF
    Br J Radiol, 2016 Oct;89(1066):20160258.
    PMID: 27452264 DOI: 10.1259/bjr.20160258
    OBJECTIVE: To investigate the sensitivity and robustness of a volumetric breast density (VBD) measurement system to errors in the imaging physics parameters including compressed breast thickness (CBT), tube voltage (kVp), filter thickness, tube current-exposure time product (mAs), detector gain, detector offset and image noise.

    METHODS: 3317 raw digital mammograms were processed with Volpara(®) (Matakina Technology Ltd, Wellington, New Zealand) to obtain fibroglandular tissue volume (FGV), breast volume (BV) and VBD. Errors in parameters including CBT, kVp, filter thickness and mAs were simulated by varying them in the Digital Imaging and Communications in Medicine (DICOM) tags of the images up to ±10% of the original values. Errors in detector gain and offset were simulated by varying them in the Volpara configuration file up to ±10% from their default values. For image noise, Gaussian noise was generated and introduced into the original images.

    RESULTS: Errors in filter thickness, mAs, detector gain and offset had limited effects on FGV, BV and VBD. Significant effects in VBD were observed when CBT, kVp, detector offset and image noise were varied (p 

  3. Leong SS, Wong JHD, Md Shah MN, Vijayananthan A, Jalalonmuhali M, Ng KH
    Br J Radiol, 2018 Sep;91(1089):20180235.
    PMID: 29869920 DOI: 10.1259/bjr.20180235
    OBJECTIVE: To investigate the use of shear wave elastography (SWE)-derived estimates of Young's modulus (YM) as an indicator to detect abnormal renal tissue diagnosed by estimated glomerular filtration rate (eGFR).

    METHODS: The study comprised 106 chronic kidney disease (CKD) patients and 203 control subjects. Conventional ultrasound was performed to measure the kidney length and cortical thickness. SWE imaging was performed to measure renal parenchymal stiffness. Diagnostic performance of SWE and conventional ultrasound were correlated with serum creatinine, urea levels and eGFR.

    RESULTS: Pearson's correlation coefficient revealed a negative correlation between YM measurements and eGFR (r = -0.576, p < 0.0001). Positive correlations between YM measurements and age (r = 0.321, p < 0.05), serum creatinine (r = 0.375, p < 0.0001) and urea (r = 0.287, p < 0.0001) were also observed. The area under the receiver operating characteristic curve for SWE (0.87) was superior to conventional ultrasound alone (0.35-0.37). The cut-off value of less or equal to 4.31 kPa suggested a non-diseased kidney (80.3% sensitivity, 79.5% specificity).

    CONCLUSION: SWE was superior to renal length and cortical thickness in detecting CKD. A value of 4.31 kPa or less showed good accuracy in determining whether a kidney was diseased or not. Advances in knowledge: On SWE, CKD patients show greater renal parenchymal stiffness than non-CKD patients. Determining a cut-off value between normal and diseased renal parenchyma may help in early non-invasive detection and management of CKD.

  4. Ng AH, Alqahtani MS, Jambi LK, Bugby SL, Lees JE, Perkins AC
    Br J Radiol, 2019 Jun;92(1098):20190020.
    PMID: 30864832 DOI: 10.1259/bjr.20190020
    OBJECTIVE: To examine the imaging capability of a novel small field of view hybrid gamma camera (HGC) using 125I seeds prior to surgical use.

    METHODS: The imaging performance of the camera system was assessed quantitatively and qualitatively at different source depths, source to collimator distances (SCD), activity levels, acquisition times and source separations, utilising bespoke phantoms.

    RESULTS: The system sensitivity and spatial resolution of the HGC for 125I were 0.41 cps/MBq (at SCD 48 mm) and 1.53 ± 0.23 mm (at SCD 10 mm) respectively. The camera was able to detect the 125I seed at a SCD of 63 mm (with no scattering material in place) in images recorded within a 1-min acquisition time. The detection of the seeds beneath scattering material (simulating deep-seated tumours) was limited to depths of less than 20 mm beneath the skin surface with a SCD of 63 mm and seed activity of 2.43 MBq. Subjective assessments of the hybrid images acquired showed the capability of the HGC for localising the 125I seeds.

    CONCLUSION: This preliminary ex vivo study demonstrates that the HGC is capable of detecting 125I seeds and could be a useful tool in radioactive seed localisation with the added benefit of providing hybrid optical γ images for guiding breast conserving surgery.

    ADVANCES IN KNOWLEDGE: The SFOV HGC could provide high resolution fused optical-gamma images of 125I radioactive seeds indicating the potential use in intraoperative surgical procedure such as RSL.

  5. Tan SK, Yeong CH, Raja Aman RRA, Ng KH, Abdul Aziz YF, Chee KH, et al.
    Br J Radiol, 2018 Jul;91(1088):20170874.
    PMID: 29493261 DOI: 10.1259/bjr.20170874
    OBJECTIVE: This study aimed (1) to perform a systematic review on scanning parameters and contrast medium (CM) reduction methods used in prospectively electrocardiography (ECG-triggered low tube voltage coronary CT angiography (CCTA), (2) to compare the achievable dose reduction and image quality and (3) to propose appropriate scanning techniques and CM administration methods.

    METHODS: A systematic search was performed in PubMed, the Cochrane library, CINAHL, Web of Science, ScienceDirect and Scopus, where 20 studies were selected for analysis of scanning parameters and CM reduction methods.

    RESULTS: The mean effective dose (HE) ranged from 0.31 to 2.75 mSv at 80 kVp, 0.69 to 6.29 mSv at 100 kVp and 1.53 to 10.7 mSv at 120 kVp. Radiation dose reductions of 38 to 83% at 80 kVp and 3 to 80% at 100 kVp could be achieved with preserved image quality. Similar vessel contrast enhancement to 120 kVp could be obtained by applying iodine delivery rate (IDR) of 1.35 to 1.45 g s-1 with total iodine dose (TID) of between 10.9 and 16.2 g at 80 kVp and IDR of 1.08 to 1.70 g s-1 with TID of between 18.9 and 20.9 g at 100 kVp.

    CONCLUSION: This systematic review found that radiation doses could be reduced to a rate of 38 to 83% at 80 kVp, and 3 to 80% at 100 kVp without compromising the image quality. Advances in knowledge: The suggested appropriate scanning parameters and CM reduction methods can be used to help users in achieving diagnostic image quality with reduced radiation dose.

  6. Mohd Norsuddin N, Mello-Thoms C, Reed W, Rickard M, Lewis S
    Br J Radiol, 2017 Aug;90(1076):20170048.
    PMID: 28621548 DOI: 10.1259/bjr.20170048
    OBJECTIVE: This study investigated whether certain mammographic appearances of breast cancer are missed when radiologists read at lower recall rates.

    METHODS: 5 radiologists read 1 identical test set of 200 mammographic (180 normal cases and 20 abnormal cases) 3 times and were requested to adhere to 3 different recall rate conditions: free recall, 15% and 10%. The radiologists were asked to mark the locations of suspicious lesions and provide a confidence rating for each decision. An independent expert radiologist identified the various types of cancers in the test set, including the presence of calcifications and the lesion location, including specific mammographic density.

    RESULTS: Radiologists demonstrated lower sensitivity and receiver operating characteristic area under the curve for non-specific density/asymmetric density (H = 6.27, p = 0.04 and H = 7.35, p = 0.03, respectively) and mixed features (H = 9.97, p = 0.01 and H = 6.50, p = 0.04, respectively) when reading at 15% and 10% recall rates. No significant change was observed on cancer characterized with stellate masses (H = 3.43, p = 0.18 and H = 1.23, p = 0.54, respectively) and architectural distortion (H = 0.00, p = 1.00 and H = 2.00, p = 0.37, respectively). Across all recall conditions, stellate masses were likely to be recalled (90.0%), whereas non-specific densities were likely to be missed (45.6%).

    CONCLUSION: Cancers with a stellate mass were more easily detected and were more likely to continue to be recalled, even at lower recall rates. Cancers with non-specific density and mixed features were most likely to be missed at reduced recall rates. Advances in knowledge: Internationally, recall rates vary within screening mammography programs considerably, with a range between 1% and 15%, and very little is known about the type of breast cancer appearances found when radiologists interpret screening mammograms at these various recall rates. Therefore, understanding the lesion types and the mammographic appearances of breast cancers that are affected by readers' recall decisions should be investigated.

  7. Seow P, Wong JHD, Ahmad-Annuar A, Mahajan A, Abdullah NA, Ramli N
    Br J Radiol, 2018 Dec;91(1092):20170930.
    PMID: 29902076 DOI: 10.1259/bjr.20170930
    OBJECTIVE:: The diversity of tumour characteristics among glioma patients, even within same tumour grade, is a big challenge for disease outcome prediction. A possible approach for improved radiological imaging could come from combining information obtained at the molecular level. This review assembles recent evidence highlighting the value of using radiogenomic biomarkers to infer the underlying biology of gliomas and its correlation with imaging features.

    METHODS:: A literature search was done for articles published between 2002 and 2017 on Medline electronic databases. Of 249 titles identified, 38 fulfilled the inclusion criteria, with 14 articles related to quantifiable imaging parameters (heterogeneity, vascularity, diffusion, cell density, infiltrations, perfusion, and metabolite changes) and 24 articles relevant to molecular biomarkers linked to imaging.

    RESULTS:: Genes found to correlate with various imaging phenotypes were EGFR, MGMT, IDH1, VEGF, PDGF, TP53, and Ki-67. EGFR is the most studied gene related to imaging characteristics in the studies reviewed (41.7%), followed by MGMT (20.8%) and IDH1 (16.7%). A summary of the relationship amongst glioma morphology, gene expressions, imaging characteristics, prognosis and therapeutic response are presented.

    CONCLUSION:: The use of radiogenomics can provide insights to understanding tumour biology and the underlying molecular pathways. Certain MRI characteristics that show strong correlations with EGFR, MGMT and IDH1 could be used as imaging biomarkers. Knowing the pathways involved in tumour progression and their associated imaging patterns may assist in diagnosis, prognosis and treatment management, while facilitating personalised medicine.

    ADVANCES IN KNOWLEDGE:: Radiogenomics can offer clinicians better insight into diagnosis, prognosis, and prediction of therapeutic responses of glioma.

  8. Chew MT, Daar E, Khandaker MU, Jones B, Nisbet A, Bradley DA
    Br J Radiol, 2021 Aug 01;94(1124):20201265.
    PMID: 34192471 DOI: 10.1259/bjr.20201265
    Infection, the invasion of pathogenic microorganisms and viruses, causes reactive inflammation mediated by endogenous signals, with influx of leucocytes with distinct properties and capable of mounting a cellular or antibody response. Different forms of inflammation may also occur in response to tumours, in allergy and autoimmune disorders. Pneumonia, respiratory tract infection and septic shock for instance can arise as serious complications of the Covid-19 virus. While radiotherapy has been most widely used to control malignant tumours, it has also been used for treatment of non-malignant diseases, including acute and chronic inflammation in situations where anti-inflammatory drugs may be ineffective or contraindicated. The present review examines the history and prospects for low-dose anti-inflammatory radiation treatments, the present interest largely being motivated by the increased incidence of pulmonary disease associated Covid-19 infections. Evidence in support of the suggested efficacy are covered, together with an appraisal of one of the number of potential convenient sources that could complement external beam arrangements.
  9. Leong SS, Jalalonmuhali M, Md Shah MN, Ng KH, Vijayananthan A, Hisham R, et al.
    Br J Radiol, 2023 Mar 01;96(1144):20220288.
    PMID: 36802861 DOI: 10.1259/bjr.20220288
    OBJECTIVE: Many studies have conflicting findings in using shear wave elastography (SWE) to assess renal fibrosis. This study reviews the use of SWE to evaluate pathological changes in native kidneys and renal allografts. It also tries to elucidate the confounding factors and care taken to ensure the results are consistent and reliable.

    METHODS: The review was carried out according to the Preferred Reporting Items for Systematic Reviews and Meta-Analysis guidelines. Literature search was conducted in Pubmed, Web of Science and Scopus database up to 23 October 2021. To evaluate risk and bias applicability, the Cochrane risk-of bias tool and GRADE was used. The review was registered under PROSPERO CRD42021265303.

    RESULTS: A total of 2921 articles were identified. 104 full texts were examined and 26 studies included in systematic review. 11 studies performed on native kidneys and 15 studies on transplanted kidney. A wide range of impact factors was found that affect the accuracy of SWE of renal fibrosis in adult patients.

    CONCLUSIONS: Compared to point SWE, two-dimensional SWE with elastogram could enable better selection of the region of interest in kidneys, leading to reproducible results. Tracking waves were attenuated as the depth from skin to region of interest increased, therefore, SWE is not recommended for overweight or obese patients. Variable transducer forces might also affect SWE reproducibility, thus, training of operators to ensure consistent operator-dependent transducer forces may be helpful.

    ADVANCES IN KNOWLEDGE: This review provides a holistic insight on the efficiency of using SWE in evaluating pathological changes in native and transplanted kidneys, thereby contributing to the knowledge of its utilisation in clinical practice.

  10. Hanafiah M, Johari B, Ab Mumin N, Musa AA, Hanafiah H
    Br J Radiol, 2022 May 01;95(1133):20210857.
    PMID: 35007174 DOI: 10.1259/bjr.20210857
    OBJECTIVE: Primary open-angle glaucoma (POAG) is a degenerative optic neuropathy disease which has somewhat similar pathophysiology to Alzheimer's disease (AD). This study aims to determine the presence of medial temporal atrophy and parietal lobe atrophy in patients with POAG compared to normal controls using medial temporal atrophy (MTA) scoring and posterior cortical atrophy (PCA) scoring system on T1 magnetization-prepared rapid gradient-echo.

    METHODS: 50 POAG patients and 50 normal subjects were recruited and an MRI brain with T1-magnetization-prepared rapid gradient-echo was performed. Medial temporal lobe and parietal lobe atrophy were by MTA and PCA/Koedam scoring. The score of the PCA and MTA were compared between the POAG group and the controls.

    RESULTS: There was a significant statistical difference between PCA score in POAG and the healthy control group (p-value = 0.026). There is no statistical difference between MTA score in POAG compared to the healthy control group (p-value = 0.58).

    CONCLUSION: This study suggests a correlation between POAG and PCA score. Potential application of this scoring method in clinical diagnosis and monitoring of POAG patients.

    ADVANCES IN KNOWLEDGE: The scoring method used in AD may also be applied in the diagnosis and monitoring of POAGMRI brain, specifically rapid volumetric T1 spoiled gradient echo sequence, may be applied in POAG assessment.

  11. Orsi F, Hamiddin AS, Sattin C, Pizzi C, Varano GM, Della Vigna P, et al.
    Br J Radiol, 2024 Sep 03.
    PMID: 39226178 DOI: 10.1093/bjr/tqae171
    OBJECTIVE: This study aimed to assess the complication rate during and 24 hours after cryoablation in lung, bone, and soft tissue tumors.

    METHODS: We reviewed complications in a total of 85 consecutive patients who underwent cryoablation using a liquid nitrogen-based system in various lesions between April 2017 and October 2022. There were none liver and renal lesions. Complications were categorized using the Society of Interventional Radiology (SIR) classification.

    RESULTS: 85 patients were treated for 96 lesions in the bone (36.4%; 35 of 96), lung (18.8%; 18 of 96), and soft tissue (44.8%; 43 of 96). The primary technical success rate was 97.7% (83 of 85). The total grade 2 and 1 complication rates were 5.2% (5/96) and 20.8% (20/96), respectively. Two patients had asymptomatic pulmonary embolisms incidentally noted at the 24-hour follow-up computed tomography (grade 2). The most frequent complications were simple and hemorrhagic pleural effusions (18.7%; 18 of 96). Lung procedures had the highest complication rate where 13 patients (72.2%; 13 of 18) reporting complications, including two cases of symptomatic hydropneumothorax requiring drainage (grade 2) and an additional two days of hospital stay. Eight patients (24.2%; 8 of 33) with bone lesions and four (9.3%; 4 of 43) with soft tissue lesions experienced complications.

    CONCLUSION: Cryoablation using a liquid nitrogen-based system is safe, with only minor complications observed.