OBJECTIVES: To analyze the presence of DPOAE across frequencies and DP amplitude in infants with and without IDA.
METHOD: DPOAE were recorded on 40 infants with IDA and 40 infants without IDA in the age range of 6-24 months. Cubic DPOAEs (2f1-f2) were measured at six f2 frequencies (1500 Hz, 2000 Hz, 3000 Hz, 4500 Hz, 6000 Hz & 8000 Hz) with primary tone stimulus of intensity L1 equal to 65 dBSPL and L2 equal to 55 dBSPL. Immittance audiometry was performed using 226 Hz probe tone prior to DPOAE recording to ascertain normal middle ear functioning.
RESULTS: DPOAEs were present in all infants with and without IDA across frequencies tested. DP amplitude across the frequencies did not show any statistically significant difference (p
METHODS: Seventeen healthy children (6 boys, 11 girls) aged from 5 to 9 years (mean = 6.8 ± 3.3 years) were tested in two sessions separated by a 3-month period. The stimulus used was a 40-ms syllable /da/ presented at 30 dB sensation level.
RESULTS: As revealed by pair t-test and intra-class correlation (ICC) analyses, peak latencies, peak amplitudes and composite onset measures of speech-ABR were found to be highly replicable. Compared to other parameters, higher ICC values were noted for peak latencies of speech-ABR.
CONCLUSION: The present study was the first to report the test-retest reliability of speech-ABR recorded at low stimulation levels in healthy children. Due to its good stability, it can be used as an objective indicator for assessing the effectiveness of auditory rehabilitation in hearing-impaired children in future studies.
DESIGN: The MHINT-T and the MyHINT were presented in quiet and noise (front, right and left) conditions under headphones. Results for the two tests were compared with each other and with the norms for each test.
STUDY SAMPLE: Malaysian Chinese native speakers of Mandarin (N = 58), 18-31 years of age with normal hearing.
RESULTS: On average, subjects demonstrated poorer speech perception ability than the normative samples for these tests. Repeated measures ANOVA showed that speech reception thresholds (SRTs) were slightly poorer on the MHINT-T than on the MyHINT for all test conditions. However, normalized SRTs were poorer by 0.6 standard deviations for MyHINT as compared with MHINT-T.
CONCLUSIONS: MyHINT and MHINT-T can be used as norm-referenced speech perception measures for Mandarin-speaking Chinese in Malaysia.
DESIGN: Quasi-experimental and repeated measure study designs were applied in this study. Two different stopping criteria were used, (1) a fixed-signal averaging 4000 sweeps and, (2) a minimum quality indicator of Fmp = 3.1 with a minimum of 800 sweeps.
STUDY SAMPLE: Twenty-nine normally hearing adults (18 females, 11 male) participated.
RESULTS: Wave V amplitudes were significantly larger in the LS CE-Chirp® recorded from the vertical montage than the ipsilateral montage. Waves I and III amplitudes were significantly larger from the ipsilateral LS CE-Chirp® than from the other montages and stimulus combinations. The differences in the quality of the ABR recording between the vertical and ipsilateral montages were marginal.
CONCLUSIONS: Overall, the result suggested that the vertical LS CE-Chirp® ABR had a high potential for a threshold-seeking application, because it produced a higher wave V amplitude. The Ipsilateral LS CE-Chirp® ABR, on the other hand, might also have a high potential for the site of lesion application, because it produced larger waves I and III amplitudes.
DESIGN AND STUDY SAMPLE: Study 1 compared the FS measure obtained with MOL and 2IFC procedure at two centre frequencies (CFs) (1 and 4 kHz) in 21 normal-hearing listeners. Study 2 determined the FS measure using MOL at five CFs (0.5-8 kHz) in 32 normal-hearing and nine sensorineural hearing loss listeners and compared them with their thresholds in quiet.
RESULTS: FS measurements with MOL and 2IFC methods were highly correlated and had statistically comparable intra-subject test-retest reliability. FS measures determined with MOL were reduced in the hearing-impaired compared to normal-hearing listeners at the CF corresponding to their hearing loss. Linear regression analysis showed significant relationship between FS deterioration and quiet threshold loss (p
METHODS: A double-blind, placebo-controlled, counter-balanced crossover design with permuted block randomisation for drug order was followed. Dexamphetamine (0.45 mg/kg, PO, q.d.) was administered to healthy participants. Phantom word illusion (speech illusion) and visual-induced flash illusion/VIFI (visual illusion) tests were measured to determine if TBWs were altered as a function of delay between stimuli presentations. Word emotional content for phantom word illusions was also analysed.
RESULTS: Dexamphetamine significantly increased the total number of phantom words/speech illusions (p