Displaying publications 21 - 27 of 27 in total

Abstract:
Sort:
  1. Thanuja M, Maimanah M, Sara U
    Med J Malaysia, 2020 09;75(5):490-493.
    PMID: 32918415
    BACKGROUND: The role of nuclear medicine in diagnosing pulmonary embolism (PE) is continuously evolving owing to advancements in imaging methods. In recent years, ventilation/perfusion single photon emission computed tomography-computed tomography (V/Q SPECT/CT) has established a synergistic role over conventional V/Q planar scintigraphy and V/Q SPECT in diagnosing pulmonary embolism.

    OBJECTIVES: In this study, we aimed to assess the incremental value of V/Q SPECT/CT over conventional V/Q planar scintigraphy and V/Q SPECT, and to determine if Q only-SPECT/CT without the conventional ventilation component could replace the current imaging protocol in diagnosing pulmonary embolism.

    METHODS: We retrospectively assessed 73 patients with suspicion of pulmonary embolism who had undergone/Q planar scintigraphy, V/Q SPECT and V/Q SPECT/CT consecutively. Combination of clinical follow-up, laboratory test results and correlative imaging were used as reference standard. Q-only SPECT/CT datasets were then analysed separately without the V-planar, V-SPECT and V-SPECT/CT datasets.

    RESULTS: A total of 66 patients fulfilled our initial inclusion and exclusion criteria, with 23 patients as positive for PE and 43 patients ruled out of having PE based on the reference standard. Sensitivity and specificity for V/P planar scintigraphy, V/Q SPECT, and V/Q SPECT-CT were 86.9% and 39.5%, 91.3% and 55.8%, and 100% and 97.6% respectively. Overall, SPECT/CT resulted in significantly higher diagnostic accuracy than planar and SPECT imaging respectively (p<0.05). Q-only SPECT/CT significantly over diagnosed pulmonary embolism in 12 patients (p<0.05).

    CONCLUSION: Adding V/Q SPECT/CT to the algorithm of PE significantly improves the sensitivity and specificity. However, by eliminating the ventilation component, the diagnostic accuracy is significantly reduced.

    Matched MeSH terms: Perfusion
  2. Cheong JKK, Yap S, Ooi ET, Ooi EH
    Comput Methods Programs Biomed, 2019 Jul;176:17-32.
    PMID: 31200904 DOI: 10.1016/j.cmpb.2019.04.028
    BACKGROUND AND OBJECTIVES: Recently, there have been calls for RFA to be implemented in the bipolar mode for cancer treatment due to the benefits it offers over the monopolar mode. These include the ability to prevent skin burns at the grounding pad and to avoid tumour track seeding. The usage of bipolar RFA in clinical practice remains uncommon however, as not many research studies have been carried out on bipolar RFA. As such, there is still uncertainty in understanding the effects of the different RF probe configurations on the treatment outcome of RFA. This paper demonstrates that the electrode lengths have a strong influence on the mechanics of bipolar RFA. The information obtained here may lead to further optimization of the system for subsequent uses in the hospitals.

    METHODS: A 2D model in the axisymmetric coordinates was developed to simulate the electro-thermophysiological responses of the tissue during a single probe bipolar RFA. Two different probe configurations were considered, namely the configuration where the active electrode is longer than the ground and the configuration where the ground electrode is longer than the active. The mathematical model was first verified with an existing experimental study found in the literature.

    RESULTS: Results from the simulations showed that heating is confined only to the region around the shorter electrode, regardless of whether the shorter electrode is the active or the ground. Consequently, thermal coagulation also occurs in the region surrounding the shorter electrode. This opened up the possibility for a better customized treatment through the development of RF probes with adjustable electrode lengths.

    CONCLUSIONS: The electrode length was found to play a significant role on the outcome of single probe bipolar RFA. In particular, the length of the shorter electrode becomes the limiting factor that influences the mechanics of single probe bipolar RFA. Results from this study can be used to further develop and optimize bipolar RFA as an effective and reliable cancer treatment technique.

    Matched MeSH terms: Perfusion
  3. Baratti D, Kusamura S, Azmi N, Guaglio M, Montenovo M, Deraco M
    Ann Surg Oncol, 2020 Jan;27(1):98-106.
    PMID: 31691116 DOI: 10.1245/s10434-019-07935-2
    BACKGROUND: The Prodige-7 trial has questioned the role of hyperthermic intraperitoneal chemotherapy (HIPEC) in the treatment of peritoneal metastases from colorectal cancer (CRC-PM).

    PATIENTS AND METHODS: We compared a prospectively collected group of 48 patients undergoing oxaliplatin/irinotecan-based perioperative systemic chemotherapy (s-CT) with targeted agents, and cytoreductive surgery (CRS) (no-HIPEC group) with 48 controls undergoing the same perioperative s-CT and CRS/HIPEC (HIPEC group). Patients were matched (1:1) according to the Peritoneal Surface Disease Severity Score, completeness of cytoreduction, history of extraperitoneal disease (EPD), and Peritoneal Cancer Index.

    RESULTS: The groups were comparable, except for a higher number of patients in the HIPEC group with World Health Organization performance status 0, pN2 stage primary tumor, and treated with preoperative s-CT. Forty-one patients in the no-HIPEC group and 43 patients in the HIPEC group had optimal comprehensive treatment (P = 0.759), defined as complete cytoreduction of PM and margin-negative EPD resection. Median follow-up was 31.6 months in the no-HIPEC group and 39.9 months in the HIPEC group. Median overall survival was 39.3 months in the no-HIPEC group and 34.8 months in the HIPEC group (P = 0.702). In the two groups, severe morbidity occurred in 14 (29.2%) and 13 (27.1%) patients, respectively (P = 1.000), with no operative deaths. On multivariate analysis, left-sided primary and curative treatment independently correlated with better survival while HIPEC did not (hazard ratio 0.73; 95% confidence interval 0.47-1.15; P = 0.178).

    CONCLUSIONS: Our results confirmed that, in selected patients, perioperative s-CT and surgical treatment of CRC-PM resulted in unexpectedly high survival rates. Mitomycin C-based HIPEC did not increase morbidity but did not impact prognosis.

    Matched MeSH terms: Chemotherapy, Cancer, Regional Perfusion/mortality*
  4. Venkatesh G, Ramanathan S, Nair NK, Mansor SM, Sattar MA, Khan MA, et al.
    Biomed Chromatogr, 2007 May;21(5):484-90.
    PMID: 17294505
    A simple and sensitive RP-HPLC-UV method was developed and validated for simultaneous determination of atenolol and propranolol and subsequently applied to investigate the effect of dimethyl sulfoxide in rat in situ intestinal permeability studies. Atenolol (400 microm) and propranolol (100 microm) were perfused in the small intestine of anaesthetized (pentobarbitone sodium 60 mg/kg, i.p.) male Sprague-Dawley rats either in the presence (1, 3 and 5%) or in the absence of dimethyl sulfoxide. There was no significant alteration (p > 0.05) in the permeability of atenolol and propranolol, which indicated there was no effect of various concentrations of dimethyl sulfoxide (1-5%) on the membrane integrity of the rat intestinal tissues. The analytical method was validated on a C(4) column with a mobile phase comprising ammonium acetate buffer (pH 3.5, 0.02 m) and acetonitrile in the ratio of 30:70 (v/v) at a flow rate of 1.0 mL/min. The validated method was found to be accurate and precise and stability studies were carried out at different storage conditions and both analytes were found to be stable. These findings are applicable for determining the absorbability of water-insoluble drugs and new chemical entities for the purpose of classifying them in the biopharmaceutical classification system.
    Matched MeSH terms: Perfusion
  5. Yang CY, Hoong MF, Li CS, Li WF, You SH, Lee YC, et al.
    Taiwan J Obstet Gynecol, 2021 May;60(3):517-522.
    PMID: 33966739 DOI: 10.1016/j.tjog.2021.03.023
    OBJECTIVE: To evaluate the association between intrauterine growth restriction (IUGR) and the incidence of fetuses with patent ductus arteriosus (PDA) and Hemodynamically significant PDA (Hs-PDA) in dichorionic twins (DC) with selective IUGR.

    MATERIALS AND METHODS: This is an observational cohort study and retrospective case assessment, involved twins born at Linkou Chang Gung Memorial Hospital, Taoyuan, Taiwan between 2013 and 2018. DC twins with selective IUGR (sIUGR) were defined as the presence of a birth weight discordance of >25% and a smaller twin with a birth weight below the tenth percentile. PDA was diagnosed using echocardiography between postnatal day 3 and 7. Hs-PDA was defined as PDA plus increased pulmonary circulation, poor systemic perfusion, cardiomegaly, pulmonary edema, or hypotension requiring pharmacotherapeutic intervention.

    RESULT: A total of 1187 twins were delivered during the study period, and 53 DC twins with selective IUGR were included in this study. DC twins with PDA have higher rate of preterm birth, lower gestational age of delivery, and lower mean birth weight of both twins compared with DC twins without PDA. In a comparison of the sIUGR twin with the appropriate for gestational age co-twin, both the incidences of PDA (28.30% vs. 7.55%, respectively; P = 0.003) and Hs-PDA (24.53% vs. 5.66%, respectively; P = 0.002) were higher in sIUGR fetuses than in the appropriate for gestational age co-twins. Small gestational age of delivery was the only variable to predict PDA and Hs-PDA [p = 0.002, Odds ratio = 0.57 (0.39-0.82), p = 0.009, Odds ratio = 0.71 (0.55-0.92), respectively].

    CONCLUSION: An analysis of dichorionic twins with sIUGR indicated that IUGR increased the risk of PDA and hemodynamically significant PDA.

    Matched MeSH terms: Perfusion
  6. Chew ST, Mar WM, Ti LK
    Br J Anaesth, 2013 Mar;110(3):397-401.
    PMID: 23171723 DOI: 10.1093/bja/aes415
    BACKGROUND: Postoperative acute kidney injury (AKI) is a frequent and serious complication after cardiac surgery. Clinical factors alone have failed to accurately predict the incidence of AKI after cardiac surgery. Ethnicity has been shown to be a predictor of AKI in the Western population. We tested the hypothesis that ethnicity is an independent predictor of AKI in patients undergoing cardiac surgery in a South East Asian population.

    METHODS: A total of 1756 consecutive patients undergoing cardiac surgery were prospectively recruited. Among them, data of 1639 patients met the criteria for analysis. There were 1182 Chinese, 195 Indian, and 262 Malay patients. The main outcome was postoperative AKI, defined as a 25% or greater increase in preoperative to a maximum postoperative serum creatinine level within 3 days after surgery.

    RESULTS: Five hundred and seventy-nine patients (35.3%) developed AKI after cardiac surgery. Ethnicity was shown to be an independent predictor of AKI after cardiac surgery with Indians and Malays having a higher risk of developing AKI when compared with Chinese patients (odds ratio: Indian vs Chinese 1.44, Malay vs Chinese 1.51).

    CONCLUSIONS: Indians and Malays have a higher risk of developing AKI after cardiac surgery than Chinese in a South East Asian population. Ethnicity was shown to be an independent predictor of AKI after cardiac surgery.

    Matched MeSH terms: Perfusion
  7. Venkatesh G, Ramanathan S, Mansor SM, Nair NK, Sattar MA, Croft SL, et al.
    J Pharm Biomed Anal, 2007 Mar 12;43(4):1546-51.
    PMID: 17157469
    A simple, sensitive and specific reversed phase high performance liquid chromatographic (RP-HPLC) method with UV detection at 251 nm was developed for simultaneous quantitation of buparvaquone (BPQ), atenolol, propranolol, quinidine and verapamil. The method was applicable in rat in situ intestinal permeability study to assess intestinal permeability of BPQ, a promising lead compound for Leishmania donovani infections. The method was validated on a C-4 column with mobile phase comprising ammonium acetate buffer (0.02 M, pH 3.5) and acetonitrile in the ratio of 30:70 (v/v) at a flow rate of 1.0 ml/min. The retention times for atenolol, quinidine, propranolol, verapamil and BPQ were 4.30, 5.96, 6.55, 7.98 and 8.54 min, respectively. The calibration curves were linear (correlation coefficient > or =0.996) in the selected range of each analyte. The method is specific and sensitive with limit of quantitation of 15 microg/ml for atenolol, 0.8 microg/ml for quinidine, 5 microg/ml for propranolol, 10 microg/ml for verapamil and 200 ng/ml for BPQ. The validated method was found to be accurate and precise in the working calibration range. Stability studies were carried out at different storage conditions and all the analytes were found to be stable. This method is simple, reliable and can be routinely used for accurate permeability characterization.
    Matched MeSH terms: Perfusion
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links