METHODS: This study involved 70 consecutive Lenke 1 and 2 AIS patients who underwent scoliosis correction with alternate-level pedicle screw instrumentation. Preoperative parameters that were measured included main thoracic (MT) Cobb angle, proximal thoracic (PT) Cobb angle, lumbar Cobb angle as well as thoracic kyphosis. Side-bending flexibility (SBF) and fulcrum-bending flexibility (FBF) were derived from the measurements. Preoperative height and post-operative height increment was measured by an independent observer using a standardized method.
RESULTS: MT Cobb angle and FB Cobb angle were significant predictors ( p < 0.001) of height increment from multiple linear regression analysis ( R = 0.784, R2 = 0.615). PT Cobb angle, lumbar, SB Cobb angle, preoperative height and number of fused segment were not significant predictors for the height increment based on the multivariable analysis. Increase in post-operative height could be calculated by the formula: Increase in height (cm) = (0.09 × preoperative MT Cobb angle) - (0.04 x FB Cobb angle) - 0.5.
CONCLUSION: The proposed formula of increase in height (cm) = (0.09 × preoperative MT Cobb angle) - (0.04 × FB Cobb angle) - 0.5 could predict post-operative height gain to within 5 mm accuracy in 51% of patients, within 10 mm in 70% and within 15 mm in 86% of patients.
OBJECTIVE: To investigate the association between postoperative upper instrumented vertebrae (UIV) tilt angle with postoperative medial shoulder and neck imbalance.
SUMMARY OF BACKGROUND DATA: Studies had found that current recommendations for UIV selection were not predictive of good postoperative shoulder balance.
METHODS: A total of 98 patients with adolescent idiopathic scoliosis with Lenke 1/2 curves who underwent posterior spinal fusion between 2013 and 2014 with minimum follow-up of 2 years were recruited. Radiological parameters: UIV tilt angle, T1 tilt, cervical axis, and clavicle angle were measured preoperatively, postoperatively, and at final follow-up.
RESULTS: Mean age was 16.2 ± 6.2 years. Mean follow-up was 37.9 ± 6.5 months. There were 73.5% Lenke 1 and 26.5% Lenke 2 curves. Significant factors affecting postoperative T1 Tilt were postoperative UIV tilt angle, preoperative T1 tilt, and preoperative UIV tilt angle. Postoperative UIV tilt angle and preoperative cervical axis were significant factors affecting cervical axis at final follow-up. UIV level was not significant independent factor that affected postoperative T1 tilt and cervical axis. There was strong correlation between postoperative UIV tilt angle and T1 tilt for the whole cohort (P
METHODS: This was a retrospective computerized tomography (CT) evaluation study of 880 fluoroscopic guided percutaneous pedicle screws. 440 screws were inserted in 73 European patients and 440 screws were inserted in 75 Asian patients. Screw perforations were classified into Grade 0: no violation; Grade 1: <2 mm perforation; Grade 2: 2-4 mm perforation; and Grade 3: >4 mm perforation. For anterior perforations, the pedicle perforations were classified into Grade 0: no violation, Grade 1: <4 mm perforation; Grade 2: 4-6 mm perforation; and Grade 3: >6 mm perforation.
RESULTS: The inter-rater reliability was adequate with a kappa value of 0.83. The mean age of the study group was 58.3 ± 15.6 years. The indications for surgery were tumor (70.3 %), infection (18.2 %), trauma (6.8 %), osteoporotic fracture (2.7 %) and degenerative diseases (2.0 %). The overall screw perforation rate was 9.7 %, in Europeans 9.1 % and in Asians 10.2 % (p > 0.05). Grade 1 perforation rate was 8.4 %, Grade 2 was 1.2 % and Grade 3 was 0.1 % with no difference in the grade of perforations between Europeans and Asians (p > 0.05). The perforation rate was the highest in T1 (33.3 %), followed by T6 (14.5 %) and T4 (14.0 %). Majority of perforations occurred medially (43.5 %), followed by laterally (25.9 %), and anteriorly (23.5 %). There was no statistical significant difference (p > 0.05) in the perforation rates between right-sided pedicle screws and left-sided pedicle screws (R: 10.0 %, L: 9.3 %).
CONCLUSIONS: There were no statistical significant differences in the overall perforation rates, grades of perforations, direction of perforations for implantation of percutaneous thoracic pedicle screws insertion using fluoroscopic guidance between Europeans and Asians. The safety profile for this technique was comparable to the current reported perforation rates for conventional open pedicle screw technique.
OBJECTIVE: The primary objective of this study was to assess the conformity of the radiological neck and shoulder balance parameters throughout a follow-up period of more than 2 years.
SUMMARY OF BACKGROUND DATA: Postoperative shoulder and neck imbalance are undesirable features among Adolescent Idiopathic Scoliosis patients who underwent Posterior Spinal Fusion. There are many clinical and radiological parameters used to assess this clinical outcome. However, we do not know whether these radiological parameters conform throughout the entire follow-up period.
METHODS: This was a retrospective study done in a single academic institution. Inclusion criteria were patients with scoliosis who underwent posterior instrumented spinal fusion with pedicle screw fixation and attended all scheduled follow-ups for at least 24 months postoperatively. Radiological shoulder parameters were measured from both preoperative antero-posterior and postoperative antero-posterior radiographs. Lateral shoulder parameters were: Radiographic Shoulder Height, Clavicle Angle (Cla-A), Clavicle-Rib Intersection Difference, and Coracoid Height Difference. Medial shoulder and neck parameters were: T1 Tilt and Cervical Axis (CA).
RESULTS: The radiographs of 50 patients who had surgery done from November 2013 to November 2015 were analyzed. Mean age of this cohort was 16.3 ± 7.0 years. There were 38 (76%) female patients and 12 (24%) male patients. Mean final follow-up was 38.6 ± 5.8 months. When conformity assessment of the radiological parameter using the interclass coefficient correlation was done, we found that all parameters had significant correlation (P
OBJECTIVE: To determine whether the severity of the curve magnitude in Lenke 1 and 2 Adolescent Idiopathic Scoliosis (AIS) patients affects the distance and position of the aorta from the vertebra.
SUMMARY OF BACKGROUND DATA: There were studies that looked into the position of the aorta in scoliotic patients but none of them documented the change in distance of the aorta to the vertebra in relation to the magnitude of the scoliosis.
METHODS: Patients with Lenke 1 and 2 AIS who underwent posterior spinal fusion using pedicle screw construct and had a preoperative computed tomography (CT) scan performed were recruited. The radiological parameters measured on preoperative CT scan were: Aortic-Vertebral Distance (AVD), Entry-Aortic Distance (EAD), Aortic-Vertebral angle (AVA), Pedicle Aorta angle/Aortic Alpha angle (α angle), and Aortic Beta angle (β angle).
RESULTS: Thirty-nine patients were recruited. Significant moderate to strong positive correlation was found between AVD and Cobb angle from T8 to T12 vertebrae (r = 0.360 to 0.666). The EAD was generally small in the thoracic region (T4-T10) with mean EAD of less than 30 mm. Among all apical vertebrae, the mean AVD was 5.9 ± 2.2 mm with significant moderate-strong positive correlation to Cobb angle (r = 0.580). The mean α angle was 37.7 ± 8.7° with significant weak positive correlation with Cobb angle (r = 0.325).
CONCLUSION: The larger the scoliotic curve, the aorta was located further away from the apical vertebral wall. The aorta has less risk of injury from the left lateral pedicle screw breach in larger scoliotic curve at the apical region. The distance from the pedicle screw entry point to the wall of the aorta was generally small (less than 30 mm) in the thoracic region (T4-T10).
LEVEL OF EVIDENCE: 4.
METHODS: Computed tomography scans from 74 patients were retrospectively evaluated between January 2008 and December 2012. Pedicle perforations were classified by two types of grading systems. For medial, lateral, superior and inferior perforations: grade 0 - no violation; grade 1 - <2 mm; grade 2 - 2-4 mm and grade 3 - >4 mm. For anterior perforations: grade 0 - no violation; grade 1 - <4 mm; grade 2 - 4-6 mm and grade 3 - >6 mm.
RESULTS: There were 35 (47.3%) male and 39 (52.7%) female patients with a total 260 thoracic pedicle screws (T1-T6) analysed. There were 32 screw perforations which account to a perforation rate of 12.3% (11.2% grade 1, 0.7% grade 2 and 0.4% grade 3). None led to pedicle screw-related complications. The perforation rate was highest at T1 (33.3%, all grade 1 perforations), followed by T6 (14.5%) and T4 (14.0%).
CONCLUSION: Fluoroscopic guided percutaneous pedicle screws of the upper thoracic spine (T1-T6) are technically more demanding and carry potential risks of serious complications. Extra precautions need to be taken when fluoroscopic guided percutaneous pedicle screws are placed at T1 and T2 levels, due to high medial pedicular angulation and obstruction of lateral fluoroscopic images by the shoulder girdle and at T4-T6 levels, due to smaller pedicular width.
METHODS: All surgeries were performed by minimally invasive technique with either percutaneous monoaxial or percutaneous polyaxial screws inserted at adjacent fracture levels perpendicular to both superior end plates. Fracture reduction is achieved with adequate rod contouring and distraction maneuver. Radiological parameters were measured during preoperation, postoperation, and follow-up.
RESULTS: A total of 21 patients were included. Eleven patients were performed with monoaxial pedicle screws and 10 patients performed with polyaxial pedicle screws. Based on AO thoracolumbar classification system, 10 patients in the monoaxial group had A3 fracture type and 1 had A4. In the polyaxial group, six patients had A3 and four patients had A4. Total correction of anterior vertebral height (AVH) ratio was 0.30 ± 0.10 and 0.08 ± 0.07 in monoaxial and polyaxial groups, respectively (p < 0.001). Total correction of posterior vertebral height (PVH) ratio was 0.11 ± 0.05 and 0.02 ± 0.02 in monoaxial and polyaxial groups, respectively (p < 0.001). Monoaxial group achieved more correction of 13° (62.6%) in local kyphotic angle compared to 8.2° (48.0%) in polyaxial group. Similarly, in regional kyphotic angle, 16.5° (103.1%) in the monoaxial group and 8.1° (76.4%) in the polyaxial group were achieved.
CONCLUSIONS: Monoaxial percutaneous pedicle screws inserted at adjacent fracture levels provided significantly better fracture reduction compared to polyaxial screws in thoracolumbar fractures.
METHODS: The scoliosis curves were divided into eight zones. CT scans were used to assess perforations: Grade 0, Grade 1( 4 mm). Anterior perforations were classified into Grade 0, Grade 1( 6 mm). Grade 2 and 3 (except lateral grade 2 and 3 perforation over thoracic vertebrae) were considered as 'critical perforations'.
RESULTS: 1986 screws in 137 patients were analyzed. The overall perforation rate was 8.4% after exclusion of the lateral perforation. The highest medial perforation rate was at the transitional proximal thoracic (PT)/main thoracic (MT) zone (6.9%), followed by concave lumbar (6.7%) and convex main thoracic (MT) zone (6.1%). The overall critical medial perforation rate was 0.9%. 33.3% occurred at convex MT and 22.2% occurred at transitional PT/MT zone. There were 39 anterior perforations (overall perforation rate of 2.0%). 43.6% occurred at transitional PT/MT zone, whereas 23.1% occurred at concave PT zone. The overall critical anterior perforation rate was 0.6%. 5/12 (41.7%) critical perforations occurred at concave PT zone, whereas four perforations occurred at the transitional PT/MT zone. There were only two symptomatic left medial grade 2 perforations (0.1%) resulting radiculopathy, occurring at the transitional main thoracic (MT)/Lumbar (L) zone.
CONCLUSION: Overall pedicle perforation rate was 8.4%. Highest rate of critical medial perforation was at the convex MT zone and the transitional PT/MT zone, whereas highest rate of critical anterior perforation was at the concave PT zone and the transitional PT/MT zone. The rate of symptomatic perforations was 0.1%.
METHODS: Patients included had the diagnosis of significant back pain caused by osteoporotic vertebral compression fracture secondary to trivial injury. All the patients underwent routine preoperative sitting lateral spine radiograph, supine stress lateral spine radiograph, and supine anteroposterior spine radiograph. The radiological parameters recorded were anterior vertebral height (AVH), middle vertebral height (MVH), posterior vertebral height (PVH), MVH level below, wedge endplate angle (WEPA), and regional kyphotic angle (RKA). The supine stress versus sitting difference (SSD) for all the above parameters were calculated.
RESULTS: A total of 28 patients (4 males; 24 females) with the mean age of 75.6 ± 7.7 years were recruited into this study. The mean cement volume injected was 5.5 ± 1.8 ml. There was no difference between supine stress and postoperative radiographs for AVH ( p = 0.507), PVH ( p = 0.913) and WEPA ( p = 0.379). The MVH ( p = 0.026) and RKA ( p = 0.005) were significantly less in the supine stress radiographs compared to postoperative radiographs. There was significant correlation ( p < 0.05) between supine stress and postoperative AVH, MVH, PVH, WEPA, and RKA. The SSD for AVH, PVH, WEPA, and RKA did not have significant correlation with the cement volume ( p > 0.05). Only the SSD-MVH had significant correlation with cement volume, but the correlation was weak ( r = 0.39, p = 0.04).
CONCLUSIONS: Dynamic mobility stress radiographs can predict the postoperative vertebral height restoration and kyphosis correction after vertebroplasty for thoracolumbar osteoporotic fracture with intravertebral clefts. However, it did not reliably predict the amount of cement volume injected as it was affected by other factors.